Survey of contrasts of polymers under a high-contrast X-ray computerized tomography

被引:11
|
作者
Nishikawa, Yukihiro [1 ]
Hatanaka, Yusuke [1 ]
Iizuka, Shungo [1 ]
Takahashi, Masaoki [1 ]
机构
[1] Kyoto Inst Technol, Dept Macromol Sci & Engn, Sakyo Ku, Kyoto 6068585, Japan
关键词
X-ray computerized tomography; Polymer blends; Three-dimensional imaging; BICONTINUOUS STRUCTURE; MIXTURE;
D O I
10.1016/j.polymer.2012.07.040
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Contrasts of the polymer materials under a high contrast X-ray computerized tomography (XCT) are comprehensively investigated. We developed a high contrast XCT, and demonstrated its capabilities to polymer systems, such as polymer blends. Then we got a hypothesis that the pixel values of the cross-sectional image obtained by XCT agree with the X-ray absorption coefficient at 15 keV. This hypothesis is intensively examined by using various polymers. Consequently, we propose an empirical criterion that 0.1 cm(-1) difference in the X-ray absorption coefficients at 15 keV is necessary to distinguish the polymers under XCT. This criterion is also confirmed in the polymer blend systems. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4287 / 4292
页数:6
相关论文
共 50 条
  • [41] X-ray computerized tomography scan of crumpled aluminum sheet
    Cambou, Anne Dominique
    Menon, Narayanan
    CHAOS, 2009, 19 (04)
  • [42] X-ray computerized tomography in the differential diagnosis of gastric ulcerations
    Kazanskaya Meditsinskaya Akademiya, Kazan', Russia
    Vestn Rentgenol Radiol, 5 ([d]18-20):
  • [43] USE OF X-RAY COMPUTERIZED-TOMOGRAPHY IN COAL CHARACTERIZATION
    KOSKY, PG
    LAMBY, EJ
    MAYLOTTE, DH
    SPIRO, CS
    STPETERS, RL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1981, 181 (MAR): : 83 - ANYL
  • [44] X-RAY COMPUTERIZED-TOMOGRAPHY OF COAL DURING PYROLYSIS
    MAYLOTTE, DH
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1981, 26 (03): : 201 - 201
  • [45] Influence of filtration conditions evaluated by X-ray computerized tomography
    Maschio, C
    de Arruda, ACF
    FILTRATION + SEPARATION, 2003, 40 (04) : 45 - 47
  • [46] Desktop X-ray tomography for low contrast samples
    Hampai, D.
    Marchitto, L.
    Dabagov, S. B.
    Allocca, L.
    Alfuso, S.
    Innocenti, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 309 : 264 - 267
  • [47] Contrast agents for x-ray luminescence computed tomography
    Lun, Michael C.
    Ranasinghe, Meenakshi
    Arifuzzaman, Mohammad
    Fang, Yile
    Guo, Yiping
    Anker, Jeffrey N.
    Li, Changqing
    APPLIED OPTICS, 2021, 60 (23) : 6769 - 6775
  • [48] Quality of the reconstruction in x-ray phase contrast tomography
    Arhatari, B. D.
    Peele, A. G.
    Nugent, K. A.
    De Carlo, F.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (06):
  • [49] Numerical Modeling of Jointed Rock Under Compressive Loading Using X-ray Computerized Tomography
    Yu, Qinglei
    Yang, Shengqi
    Ranjith, P. G.
    Zhu, Wancheng
    Yang, Tianhong
    ROCK MECHANICS AND ROCK ENGINEERING, 2016, 49 (03) : 877 - 891
  • [50] Numerical Modeling of Jointed Rock Under Compressive Loading Using X-ray Computerized Tomography
    Qinglei Yu
    Shengqi Yang
    P. G. Ranjith
    Wancheng Zhu
    Tianhong Yang
    Rock Mechanics and Rock Engineering, 2016, 49 : 877 - 891