Time Trial Performance Is Sensitive to Low-Volume Autologous Blood Transfusion

被引:31
|
作者
Bejder, Jacob [1 ]
Andersen, Andreas Breenfeldt [1 ]
Solheim, Sara Amalie [1 ]
Gybel-Brask, Mikkel [2 ]
Secher, Niels Henry [3 ]
Johansson, Par Ingemar [2 ]
Nordsborg, Nikolai Baastrup [1 ]
机构
[1] Univ Copenhagen, Dept Nutr Exercise & Sports, Copenhagen, Denmark
[2] Univ Copenhagen, Rigshosp, Copenhagen Muscle Res Ctr, Sect Transfus Med, Copenhagen, Denmark
[3] Univ Copenhagen, Rigshosp, Copenhagen Muscle Res Ctr, Dept Anesthesiol, Copenhagen, Denmark
来源
关键词
SMALL-VOLUME TRANSFUSION; LARGE-VOLUME TRANSFUSION; CYCLING; ENDURANCE; INTERMITTENT EXERCISE; DOPING; INDUCED ERYTHROCYTHEMIA; ENDURANCE CAPACITY; EXERCISE; HEMOGLOBIN; REINFUSION; PHOSPHOCREATINE; DETERMINANTS; INFUSION; HUMANS; CELLS;
D O I
10.1249/MSS.0000000000001837
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose This study tested the hypothesis that autologous blood transfusion (ABT) of similar to 50% of the red blood cells (RBC) from a standard 450-mL phlebotomy would increase mean power in a cycling time trial. In addition, the study investigated whether further ABT of RBC obtained from another 450-mL phlebotomy would increase repeated cycling sprint ability. Methods In a randomized, double-blind, placebo-controlled crossover design (3-month wash-out), nine highly trained male subjects donated two 450-mL blood bags each (BT trial) or were sham phlebotomized (PLA trial). Four weeks later, a 650-kcal time trial (n = 7) was performed 3 d before and 2 h after receiving either similar to 50% (135 mL) of the RBC or a sham transfusion. On the following day, transfusion of RBC (235 mL) from the second donation or sham transfusion was completed. A 4 x 30-s all-out cycling sprint interspersed by 4 min of recovery was performed 6 d before and 3 d after the second ABT (n = 9). Results The mean power was increased in time trials from before to after transfusion (P < 0.05) in BT (213 +/- 35 vs 223 +/- 38 W; mean +/- SD) but not in PLA (223 +/- 42 vs 224 +/- 46 W). In contrast, the mean power output across the four 30-s sprint bouts remained similar in BT (639 +/- 35 vs 644 +/- 26 W) and PLA (638 +/- 43 vs 639 +/- 25 W). Conclusions ABT of only similar to 135 mL of RBC is sufficient to increase mean power in a 650-kcal cycling time trial by similar to 5% in highly trained men. In contrast, a combined high-volume transfusion of similar to 135 and similar to 235 mL of RBC does not alter 4 x 30-s all-out cycling performance interspersed with 4 min of recovery.
引用
收藏
页码:692 / 700
页数:9
相关论文
共 50 条
  • [31] Simethicone improves bowel cleansing with low-volume polyethylene glycol: a multicenter randomized trial
    Zhang, Shenghong
    Zheng, Danping
    Wang, Jinping
    Wu, Jianwei
    Lei, Pingguang
    Luo, Qi
    Wang, Liping
    Zhang, Beiping
    Wang, Hong
    Cui, Yi
    Chen, Minhu
    ENDOSCOPY, 2018, 50 (04) : 412 - 422
  • [32] LOW-VOLUME FLUORESCENCE DETECTOR FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    BERTHOD, A
    LI, KP
    YU, TI
    WINEFORDNER, JD
    ANALYTICAL CHEMISTRY, 1987, 59 (10) : 1485 - 1488
  • [33] Granular overlays on low-volume roads in Washington State - Structural and performance characteristics
    Uhlmeyer, JS
    Mahoney, JP
    Lovejoy, JS
    Gibson, GE
    DESIGN AND REHABILITATION OF PAVEMENTS 2001: PAVEMENT DESIGN, MANAGEMENT, AND PERFORMANCE, 2001, (1778): : 182 - 190
  • [34] Development and evaluation of oxygen transfer performance of a new low-volume oxygenator.
    Esipova, Olga
    Esipov, Alexey
    Kuleshov, Arkadiy
    Bogdanov, Vladimir
    Stahanova, Ekaterina
    Buchnev, Alexander
    Grudinin, Nikita
    TRANSPLANTATION, 2024, 108 (9S)
  • [35] Low-volume reduced bowel preparation regimen for CT colonography: a randomized noninferiority trial
    Davide Bellini
    Nicola Panvini
    Simone Vicini
    Marco Rengo
    Paola Lucchesi
    Damiano Caruso
    Iacopo Carbone
    Andrea Laghi
    Abdominal Radiology, 2021, 46 : 4556 - 4566
  • [36] A randomized, prospective trial on efficacy and tolerability of low-volume bowel preparation methods for colonoscopy
    Yoo, In Kyung
    Lee, Jong Soo
    Chun, Hoon Jai
    Jeen, Yoon Tae
    Keum, Bora
    Kim, Eun Sun
    Choi, Hyuk Soon
    Lee, Jae Min
    Kim, Seung Han
    Nam, Seung Joo
    Kang, Hyo Sung
    Lee, Hong Sik
    Kim, Chang Duck
    Um, Soon Ho
    Seo, Yeon Seok
    Ryu, Ho Sang
    DIGESTIVE AND LIVER DISEASE, 2015, 47 (02) : 131 - 137
  • [37] Abiraterone in low-volume metastatic hormone-sensitive prostate cancer. Authors' reply
    Borque-Fernando, A.
    Calleja-Hernandez, M. A.
    Cozar-Olmo, J. M.
    Gomez-Iturriaga, A.
    Perez-Fentes, D. A.
    Puente-Vazquez, J.
    Rodrigo-Aliaga, M.
    Unda, M.
    Alvarez-Ossorio, J. L.
    ACTAS UROLOGICAS ESPANOLAS, 2023, 47 (06): : 392 - 393
  • [38] Low-volume reduced bowel preparation regimen for CT colonography: a randomized noninferiority trial
    Bellini, Davide
    Panvini, Nicola
    Vicini, Simone
    Rengo, Marco
    Lucchesi, Paola
    Caruso, Damiano
    Carbone, Iacopo
    Laghi, Andrea
    ABDOMINAL RADIOLOGY, 2021, 46 (10) : 4556 - 4566
  • [39] Low Volume Blood Product Transfusion Patterns And Ratios After Injury
    Ammann, Allison M.
    Wallen, Taylor E.
    Delman, Aaron M.
    Turner, Kevin M.
    Salvator, Ann
    Pritts, Timothy A.
    Makley, Amy T.
    Goodman, Michael D.
    AMERICAN JOURNAL OF SURGERY, 2022, 224 (05): : 1319 - 1323
  • [40] Detection of a Small-Volume Autologous Blood Transfusion by Hepcidin, Erythroferrone, and the Athlete Biological Passport
    Andersen, Andreas Breenfeldt
    Bejder, Jacob
    Bonne, Thomas
    Sorensen, Henrik
    Jung, Grace
    Ganz, Tomas
    Nemeth, Elizabeta
    Secher, Niels
    Johansson, Per
    Nordsborg, Nikolai
    FASEB JOURNAL, 2021, 35