Compensation for geometric modeling errors by positioning of electrodes in electrical impedance tomography

被引:11
|
作者
Hyvonen, N. [1 ]
Majander, H. [1 ,2 ]
Staboulis, S. [3 ]
机构
[1] Aalto Univ, Dept Mat & Syst Anal, POB 11100, FI-00076 Aalto, Finland
[2] Ecole Polytech, Ctr Math Appl, Route de Saclay, F-91128 Palaiseau, France
[3] Tech Univ Denmark, Dept Appl Math & Comp Sci, Asmussens Alle,Bldg 322, DK-2800 Lyngby, Denmark
基金
芬兰科学院;
关键词
electrical impedance tomography; geometric modeling errors; electrode movement; inaccurate measurement model; complete electrode model; conformal invariance; INVERSE CONDUCTIVITY PROBLEM; SIMULTANEOUS RECONSTRUCTION; BOUNDARY; SHAPE;
D O I
10.1088/1361-6420/aa59d0
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
Electrical impedance tomography aims at reconstructing the conductivity inside a physical body from boundary measurements of current and voltage at a finite number of contact electrodes. In many practical applications, the shape of the imaged object is subject to considerable uncertainties that render reconstructing the internal conductivity impossible if they are not taken into account. This work numerically demonstrates that one can compensate for inaccurate modeling of the object boundary in two spatial dimensions by finding compatible locations and sizes for the electrodes as a part of a reconstruction algorithm. The numerical studies, which are based on both simulated and experimental data, are complemented by proving that the employed complete electrode model is approximately conformally invariant, which suggests that the obtained reconstructions in mismodeled domains reflect conformal images of the true targets. The numerical experiments also confirm that a similar approach does not, in general, lead to a functional algorithm in three dimensions.
引用
收藏
页数:23
相关论文
共 50 条
  • [31] Noise reduction of electrical impedance tomography via movable electrodes
    Huang, Cheng-Ning
    Yu, Fang-Ming
    Shih, Po-Chan
    Chung, Hung-Yuan
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2007, 35 (05) : 543 - 550
  • [32] Automatic detection of detached and erroneous electrodes in electrical impedance tomography
    Asfaw, Y
    Adler, A
    PHYSIOLOGICAL MEASUREMENT, 2005, 26 (02) : S175 - S183
  • [33] Analysis and compensation for errors in electrical impedance tomography images and ventilation-related measures due to serial data collection
    Rebecca J. Yerworth
    Inéz Frerichs
    Richard Bayford
    Journal of Clinical Monitoring and Computing, 2017, 31 : 1093 - 1101
  • [34] An improved method for thermally induced positioning errors measurement, modeling, and compensation
    Jiang, Hui
    Fan, Kaiguo
    Yang, Jianguo
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2014, 75 (9-12): : 1279 - 1289
  • [35] Analysis and compensation for errors in electrical impedance tomography images and ventilation-related measures due to serial data collection
    Yerworth, Rebecca J.
    Frerichs, Inez
    Bayford, Richard
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (05) : 1093 - 1101
  • [36] An improved method for thermally induced positioning errors measurement, modeling, and compensation
    Hui Jiang
    Kaiguo Fan
    Jianguo Yang
    The International Journal of Advanced Manufacturing Technology, 2014, 75 : 1279 - 1289
  • [37] Fast detection and data compensation for electrodes disconnection in long-term monitoring of dynamic brain electrical impedance tomography
    Zhang, Ge
    Dai, Meng
    Yang, Lin
    Li, Weichen
    Li, Haoting
    Xu, Canhua
    Shi, Xuetao
    Dong, Xiuzhen
    Fu, Feng
    BIOMEDICAL ENGINEERING ONLINE, 2017, 16
  • [38] Fast detection and data compensation for electrodes disconnection in long-term monitoring of dynamic brain electrical impedance tomography
    Ge Zhang
    Meng Dai
    Lin Yang
    Weichen Li
    Haoting Li
    Canhua Xu
    Xuetao Shi
    Xiuzhen Dong
    Feng Fu
    BioMedical Engineering OnLine, 16
  • [39] Fuzzy modeling of electrical impedance tomography images of the lungs
    Tanaka, Harki
    Siqueira Ortega, Neli Regina
    Galizia, Mauricio Stanzione
    Borges, Joao Batista
    Passos Amato, Marcelo Britto
    CLINICS, 2008, 63 (03) : 363 - 370
  • [40] Extreme sensitivity of crosshole electrical resistivity tomography measurements to geometric errors
    Wilkinson, Paul B.
    Chambers, Jonathan E.
    Lelliott, Mike
    Wealthall, Gary P.
    Ogilvy, Richard D.
    GEOPHYSICAL JOURNAL INTERNATIONAL, 2008, 173 (01) : 49 - 62