Added value of color-coded virtual non-calcium dual-energy CT in the detection of acute knee fractures in non-radiology inexpert readers

被引:4
|
作者
Yang, Su Jeong [1 ]
Jeon, Ji Young [1 ]
Lee, Sheen-Woo [1 ]
Jeong, Yu Mi [1 ]
机构
[1] Gachon Univ, Coll Med, Dept Radiol, Gil Med Ctr, 21 Namdong Daero,774beon Gil, Incheon 21565, South Korea
关键词
Dual-energy CT; DECT; Virtual non-calcium; VNCa; Fractures; Bone marrow edema; Knee; BONE-MARROW EDEMA; NONCALCIUM TECHNIQUE; DIAGNOSTIC-ACCURACY; MULTIDETECTOR CT; HIP-FRACTURES; PRINCIPLES; MANAGEMENT; UTILITY; LESIONS; OCCULT;
D O I
10.1016/j.ejrad.2020.109112
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluated the added value of dual-energy CT (DECT) virtual non-calcium (VNCa) protocol on conventional CT in the detection of acute knee fractures in non-radiology inexpert readers. Method: One hundred fifty-six patients (mean age, 51.97 years; age range, 17-86 years) with knee trauma, who underwent DECT and MRI within 3 days between April 2017 and October 2018, were retrospectively analyzed. Three readers (intern, 1st-year general surgery resident, 1st-year emergency medicine resident) independently analyzed CT alone and then with the additional color-coded DECT VNCa for fractures. A board-certified radiologist, analyzed CT and MRI series to define the reference standard. Sensitivity, specificity, and AUC were compared between the two reading sessions. Results: Fifty-seven patients had acute fractures and 99 had no fractures. Thirteen of 57 fractures were nondisplaced. The additional use of VNCa images significantly increased the mean AUC (reader 1: 0.813 vs. 0.919; reader 2: 0.842 vs. 0.930; reader 3: 0.837 vs. 0.921; P < 0.05). When only nondisplaced fractures included, the mean AUC was more increased in the combined analysis of CT and DECT VNCa (reader 1: 0.521 vs. 0.916; reader 2: 0.542 vs. 0.926; reader 3: 0.575 vs. 0.926; P < .01). Sensitivity increased by 15 %-20 % in total fracture group and by 69 %-77 % in nondisplaced fracture group over that with CT alone when both CT and DECT VNCa were used. Specificity did not differ significantly. Conclusions: The additional use of color-coded DECT VNCa protocol to conventional CT improved diagnostic performance in detecting acute knee fractures for inexperienced non-radiology readers.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Use of dual-energy CT and virtual non-calcium techniques to evaluate post-traumatic bone bruises in knees in the subacute setting
    Songtao Ai
    Mingliang Qu
    Katrina N. Glazebrook
    Yu Liu
    Peter C. Rhee
    Shuai Leng
    Cynthia H. McCollough
    Skeletal Radiology, 2014, 43 : 1289 - 1295
  • [32] Evaluation of lumbar intervertebral disc degeneration using dual energy CT virtual non-calcium imaging
    Shinohara, Yuki
    Sasaki, Fumiaki
    Ohmura, Tomomi
    Itoh, Toshihide
    Endo, Takuro
    Kinoshita, Toshibumi
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 124
  • [33] Diagnostic performance of electron-density dual-energy CT in detection of cervical disc herniation in comparison with standard gray-scale CT and virtual non-calcium images
    Shim, Euddeum
    Kim, Baek Hyun
    Kang, Woo Young
    Hong, Suk-Joo
    Kang, Chang Ho
    Ahn, Kyung-Sik
    Lee, Hyeonbin
    Kwack, Thomas J.
    EUROPEAN RADIOLOGY, 2022, 32 (04) : 2209 - 2220
  • [34] Diagnostic performance of electron-density dual-energy CT in detection of cervical disc herniation in comparison with standard gray-scale CT and virtual non-calcium images
    Euddeum Shim
    Baek Hyun Kim
    Woo Young Kang
    Suk-Joo Hong
    Chang Ho Kang
    Kyung-Sik Ahn
    Hyeonbin Lee
    Thomas J. Kwack
    European Radiology, 2022, 32 : 2209 - 2220
  • [35] Dual-Energy CT, Virtual Non-Calcium Bone Marrow Imaging of the Spine: An AI-Assisted, Volumetric Evaluation of a Reference Cohort with 500 CT Scans
    Fervers, Philipp
    Fervers, Florian
    Weisthoff, Mathilda
    Rinneburger, Miriam
    Zopfs, David
    Reimer, Robert Peter
    Pahn, Gregor
    Kottlors, Jonathan
    Maintz, David
    Lennartz, Simon
    Persigehl, Thorsten
    Hokamp, Nils Grosse
    DIAGNOSTICS, 2022, 12 (03)
  • [36] Meta-analysis of dual-energy computed tomography virtual non-calcium imaging to detect bone marrow edema
    Li, Mou
    Qui, Yali
    Song, Bin
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 95 : 124 - 129
  • [37] Detection of non-dislocated Tibial Plateau Fracture using dual energy Computed Tomography and virtual Non-Calcium Technology
    Benndorf, M.
    Russe, M. F.
    Langer, M.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (08): : 783 - 785
  • [38] Detection of fatty liver using virtual non-contrast dual-energy CT
    Zhang, Pengcheng Peter
    Choi, Hailey H.
    Ohliger, Michael A.
    ABDOMINAL RADIOLOGY, 2022, 47 (06) : 2046 - 2056
  • [39] Detection of fatty liver using virtual non-contrast dual-energy CT
    Pengcheng Peter Zhang
    Hailey H. Choi
    Michael A. Ohliger
    Abdominal Radiology, 2022, 47 : 2046 - 2056
  • [40] Diagnostic accuracy of color-coded virtual noncalcium dual-energy CT for the assessment of bone marrow edema in sacral insufficiency fracture in comparison to MRI
    Booz, Christian
    Noeske, Jochen
    Albrecht, Moritz H.
    Lenga, Lukas
    Martin, Simon S.
    Bucher, Andreas M.
    Huizinga, Nicole A.
    Wichmann, Julian L.
    Vogl, Thomas J.
    Yel, Ibrahim
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 129