Added value of color-coded virtual non-calcium dual-energy CT in the detection of acute knee fractures in non-radiology inexpert readers

被引:4
|
作者
Yang, Su Jeong [1 ]
Jeon, Ji Young [1 ]
Lee, Sheen-Woo [1 ]
Jeong, Yu Mi [1 ]
机构
[1] Gachon Univ, Coll Med, Dept Radiol, Gil Med Ctr, 21 Namdong Daero,774beon Gil, Incheon 21565, South Korea
关键词
Dual-energy CT; DECT; Virtual non-calcium; VNCa; Fractures; Bone marrow edema; Knee; BONE-MARROW EDEMA; NONCALCIUM TECHNIQUE; DIAGNOSTIC-ACCURACY; MULTIDETECTOR CT; HIP-FRACTURES; PRINCIPLES; MANAGEMENT; UTILITY; LESIONS; OCCULT;
D O I
10.1016/j.ejrad.2020.109112
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluated the added value of dual-energy CT (DECT) virtual non-calcium (VNCa) protocol on conventional CT in the detection of acute knee fractures in non-radiology inexpert readers. Method: One hundred fifty-six patients (mean age, 51.97 years; age range, 17-86 years) with knee trauma, who underwent DECT and MRI within 3 days between April 2017 and October 2018, were retrospectively analyzed. Three readers (intern, 1st-year general surgery resident, 1st-year emergency medicine resident) independently analyzed CT alone and then with the additional color-coded DECT VNCa for fractures. A board-certified radiologist, analyzed CT and MRI series to define the reference standard. Sensitivity, specificity, and AUC were compared between the two reading sessions. Results: Fifty-seven patients had acute fractures and 99 had no fractures. Thirteen of 57 fractures were nondisplaced. The additional use of VNCa images significantly increased the mean AUC (reader 1: 0.813 vs. 0.919; reader 2: 0.842 vs. 0.930; reader 3: 0.837 vs. 0.921; P < 0.05). When only nondisplaced fractures included, the mean AUC was more increased in the combined analysis of CT and DECT VNCa (reader 1: 0.521 vs. 0.916; reader 2: 0.542 vs. 0.926; reader 3: 0.575 vs. 0.926; P < .01). Sensitivity increased by 15 %-20 % in total fracture group and by 69 %-77 % in nondisplaced fracture group over that with CT alone when both CT and DECT VNCa were used. Specificity did not differ significantly. Conclusions: The additional use of color-coded DECT VNCa protocol to conventional CT improved diagnostic performance in detecting acute knee fractures for inexperienced non-radiology readers.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Dual-energy CT Virtual Non-Calcium Image is Beneficial for the Detection of Non-displaced Knee Fractures
    Fang, Yijie
    Liu, Chaoran
    Yu, Wen
    Zhan, Yingying
    Li, Wenjuan
    Liang, Jianchao
    Hong, Guobin
    CURRENT MEDICAL IMAGING, 2023, 19 (10) : 1178 - 1185
  • [2] Incremental diagnostic value of color-coded virtual non-calcium dual-energy CT for the assessment of traumatic bone marrow edema of the scaphoid
    Koch, Vitali
    Mueller, Felix Christoph
    Gosvig, Kasper
    Albrecht, Moritz H.
    Yel, Ibrahim
    Lenga, Lukas
    Martin, Simon S.
    Cavallaro, Marco
    Wichmann, Julian L.
    Mader, Christoph
    D'Angelo, Tommaso
    Mazziotti, Silvio
    Cicero, Giuseppe
    Vogl, Thomas J.
    Booz, Christian
    EUROPEAN RADIOLOGY, 2021, 31 (07) : 4428 - 4437
  • [3] Incremental diagnostic value of color-coded virtual non-calcium dual-energy CT for the assessment of traumatic bone marrow edema of the scaphoid
    Vitali Koch
    Felix Christoph Müller
    Kasper Gosvig
    Moritz H. Albrecht
    Ibrahim Yel
    Lukas Lenga
    Simon S. Martin
    Marco Cavallaro
    Julian L. Wichmann
    Christoph Mader
    Tommaso D’Angelo
    Silvio Mazziotti
    Giuseppe Cicero
    Thomas J. Vogl
    Christian Booz
    European Radiology, 2021, 31 : 4428 - 4437
  • [4] Color-coded virtual non-calcium dual-energy CT for the depiction of bone marrow edema in patients with acute knee trauma: a multireader diagnostic accuracy study
    Booz, Christian
    Noeske, Jochen
    Lenga, Lukas
    Martin, Simon S.
    Yel, Ibrahim
    Eichler, Katrin
    Gruber-Rouh, Tatjana
    Huizinga, Nicole
    Albrecht, Moritz H.
    Vogl, Thomas J.
    Wichmann, Julian L.
    EUROPEAN RADIOLOGY, 2020, 30 (01) : 141 - 150
  • [5] Color-coded virtual non-calcium dual-energy CT for the depiction of bone marrow edema in patients with acute knee trauma: a multireader diagnostic accuracy study
    Christian Booz
    Jochen Nöske
    Lukas Lenga
    Simon S. Martin
    Ibrahim Yel
    Katrin Eichler
    Tatjana Gruber-Rouh
    Nicole Huizinga
    Moritz H. Albrecht
    Thomas J. Vogl
    Julian L. Wichmann
    European Radiology, 2020, 30 : 141 - 150
  • [6] Virtual non-calcium dual-energy CT: clinical applications
    Tommaso D’Angelo
    Moritz H. Albrecht
    Danilo Caudo
    Silvio Mazziotti
    Thomas J. Vogl
    Julian L. Wichmann
    Simon Martin
    Ibrahim Yel
    Giorgio Ascenti
    Vitali Koch
    Giuseppe Cicero
    Alfredo Blandino
    Christian Booz
    European Radiology Experimental, 5
  • [7] Virtual non-calcium dual-energy CT: clinical applications
    D'Angelo, Tommaso
    Albrecht, Moritz H.
    Caudo, Danilo
    Mazziotti, Silvio
    Vogl, Thomas J.
    Wichmann, Julian L.
    Martin, Simon
    Yel, Ibrahim
    Ascenti, Giorgio
    Koch, Vitali
    Cicero, Giuseppe
    Blandino, Alfredo
    Booz, Christian
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2021, 5 (01)
  • [8] Nondisplaced fractures on hip CT: added value of dual-energy CT virtual non-calcium imaging for detection of bone marrow edema using visual and quantitative analyses
    Jang, Seong Won
    Chung, Bo Mi
    Kim, Wan Tae
    Gil, Jea Ryung
    ACTA RADIOLOGICA, 2019, 60 (11) : 1465 - 1473
  • [9] Detection of bone marrow oedema in knee joints using a dual-energy CT virtual non-calcium technique
    Wang, M-Y
    Zhang, X-Y
    Xu, L.
    Feng, Y.
    Xu, Y-C
    Qi, L.
    Zou, Y-F
    CLINICAL RADIOLOGY, 2019, 74 (10) : 815.e1 - 815.e7
  • [10] Traumatic bone marrow edema of the calcaneus: Evaluation of color-coded virtual non-calcium dual-energy CT in a multi-reader diagnostic accuracy study
    Booz, Christian
    Noeske, Jochen
    Albrecht, Moritz H.
    Lenga, Lukas
    Martin, Simon S.
    Wichmann, Julian L.
    Huizing, Nicole A.
    Eichler, Katrin
    Nour-Eldin, Nour-Eldin A.
    Vogl, Thomas J.
    Yel, Ibrahim
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 118 : 207 - 214