A novel sheathless interface for capillary electrophoresis/electrospray ionization mass spectrometry using an in-capillary electrode

被引:103
|
作者
Cao, P [1 ]
Moini, M [1 ]
机构
[1] UNIV TEXAS,DEPT CHEM & BIOCHEM,AUSTIN,TX 78712
关键词
D O I
10.1016/S1044-0305(97)00015-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and rugged sheathless interface for capillary electrophoresis/electrospray ionization-mass spectrometry (CE/ESI-MS) was designed using common laboratory tools and chemicals. The interface uses a small platinum (Pt) wire that is inserted into the CE capillary through a small hole near the terminus. The position of the wire inside the CE capillary and within the buffer solution is analogous to standard CE separation operations where the terminus of the CE capillary is placed inside a buffer reservoir along with a grounded platinum electrode. By combining the use of the in-capillary electrode interface with sharpening of the fused silica tip of the CE capillary outlet, a stable electrospray current was maintained for an extended period of time. The design was successfully applied to CE/ESI-MS separations and analysis of mixtures of peptides and proteins. A detection limit of approximately 4 femtomole (S/N = 3) was achieved for detection of myoglobin utilizing a 75-mu m-i.d. aminopropylsilane treated CE column and using a wide scan range of 550-1300 Da. The advantages of this new design include (1) a stable CE and ESI current, (2) durability, (3) a reduced risk of sparking between the capillary tip and the inlet of the mass spectrometer, (4) lack of any dead volume, and (5) facile fabrication with common tools and chemicals. (C) 1997 American Society for Mass Spectrometry.
引用
收藏
页码:561 / 564
页数:4
相关论文
共 50 条
  • [31] Amino acid analysis of dried blood spots for diagnosis of phenylketonuria using capillary electrophoresis-mass spectrometry equipped with a sheathless electrospray ionization interface
    Jeong, Ji-Seon
    Kim, Sook-Kyung
    Park, Sang-Ryoul
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (25) : 8063 - 8072
  • [32] Capillary conditioning and electrospray ionization configuration for optimal capillary electrophoresis mass spectrometry performance
    Johnson, KL
    Tomlinson, AJ
    Naylor, S
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (09) : 1159 - 1160
  • [33] Optimization and Evaluation of a Sheathless Capillary Electrophoresis-Electrospray Ionization Mass Spectrometry Platform for Peptide Analysis: Comparison to Liquid Chromatography-Electrospray Ionization Mass Spectrometry
    Faserl, Klaus
    Sarg, Bettina
    Kremser, Leopold
    Lindner, Herbert
    ANALYTICAL CHEMISTRY, 2011, 83 (19) : 7297 - 7305
  • [34] New sheathless interface for coupling capillary electrophoresis to electrospray mass spectrometry evaluated by the analysis of fatty acids and prostaglandins
    Petersson, MA
    Hulthe, G
    Fogelqvist, E
    JOURNAL OF CHROMATOGRAPHY A, 1999, 854 (1-2) : 141 - 154
  • [35] Copper-coated microsprayer interface for on-line sheathless capillary electrophoresis electrospray mass spectrometry of carbohydrates
    Zamfir, AD
    Dinca, N
    Sisu, E
    Peter-Katalinic, J
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (03) : 414 - 422
  • [36] Analysis of metallothioneins by means of capillary electrophoresis coupled to electrospray mass spectrometry with sheathless interfacing
    Guo, X
    Chan, HM
    Guevremont, R
    Siu, KWM
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (06) : 500 - 507
  • [37] Snake venom characteristic peptides: novel fingerprints for species identification by sheathless capillary electrophoresis-electrospray ionization-mass spectrometry
    Liu, Ying
    Zhang, Xiao-Hui
    Yu, Yue
    Chen, Hong-Xu
    Zhou, Ying-Lin
    Zhang, Xin-Xiang
    ANALYST, 2020, 145 (14) : 5027 - 5031
  • [38] Differential detection of Rhizoma coptidis by capillary electrophoresis electrospray ionization mass spectrometry with a nanospray interface
    Liu, Jing-Xin
    Zhang, Yi-Wei
    Yuan, Fang
    Chen, Hong-Xu
    Zhang, Xin-Xiang
    ELECTROPHORESIS, 2014, 35 (21-22) : 3258 - 3263
  • [39] Twenty years of interface development for capillary electrophoresis-electrospray ionization-mass spectrometry
    Maxwell, E. Jane
    Chen, David D. Y.
    ANALYTICA CHIMICA ACTA, 2008, 627 (01) : 25 - 33
  • [40] Sheathless capillary electrophoresis electrospray ionization-mass spectrometry interface based on poly(dimethylsiloxane) membrane emitter and thin conducting liquid film
    Wang, Che-Wei
    Her, Guor-Rong
    ELECTROPHORESIS, 2013, 34 (17) : 2538 - 2545