Loading three phased transformer following the quadergy

被引:0
|
作者
Spunei, E. [1 ]
Piroi, I [1 ]
Piroi, F. [2 ]
机构
[1] Eftimie Murgu Univ Resita, Dept Elect Engn & Informat, Traian Vuia St,Str 1-4, Resita 320085, Romania
[2] Tech Univ Wien, Inst Informat Syst Engn, Vienna, Austria
关键词
D O I
10.1088/1757-899X/477/1/012018
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In this work, the authors propose a simple and fast method to establish the minimal real power for loading a three phased transformer of a specific power, such that power factor does not drop below a previously defined value. The method can be applied to transformers that are placed between a consumer's metering point and the electric power distribution network. In this situation, the billing energy and quadergy include the transformer energy and quadergy losses. This method establishes the moment where, due to low energy consumption, the transformer should be replaced with a lower power one, which still ensures the necessary energy for the consumers behind it. Our analysis has been done on a 100 kVA, an 80 KVA, and a 16 kVA transformer. Applying this method expedites the process of establishing the energy and the power factor where a transformer should be replaced by a lower power transformer, such that the power factor stays in acceptable ranges.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Co-phased traction power system based on balanced transformer and hybrid compensation
    Zhou Fulin
    Li Qunzhan
    Qiu Daqiang
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [42] Distribution transformer loading evaluation based on load profiles measurements
    Jardini, JA
    Tahan, CMV
    Ahn, SU
    Ferrari, EL
    1996 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE PROCEEDINGS, 1996, : 20 - 24
  • [43] Impacts of Transformer Loading on the Harmonic Distortion Created by GIC Flows
    Saleh, S. A.
    Zundel, E. W.
    Young-Morris, G.
    Meng, J.
    Cardenas, J.
    Hill, E. F. S.
    Brown, S.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2024, 60 (03) : 4666 - 4676
  • [44] Harmonic analysis of transformer inrush currents under loading conditions
    Huang, Ching-Lien
    Cheng, Cheng-Long
    Lin, Chin E.
    Yeh, Jim-Chwen
    Proceedings of the National Science Council, Republic of China, Part A: Physical Science and Engineering, 1992, 16 (05): : 422 - 429
  • [45] QUANTITATIVE-EVALUATION OF THE COST AND BENEFITS ASSOCIATED WITH TRANSFORMER LOADING
    BAE, YG
    ADKINS, PN
    BREE, DW
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (01): : 159 - 164
  • [46] Effects of topology and feeder capacity on substation distribution transformer loading
    Tylavsky, DJ
    Tatikonda, NR
    Alteneder, K
    Brown, KE
    IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (04) : 1425 - 1431
  • [47] Distribution transformer loading evaluation based on load profiles measurements
    Jardini, JA
    Tahan, CMV
    Ahn, SU
    Ferrari, EL
    IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (04) : 1766 - 1770
  • [48] A Probabilistic Approach for Power Transformer Dynamic Loading Capability Assessment
    Shahbazi, B.
    Savaghebi, M.
    Shariati, M.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2010, 5 (03): : 952 - 960
  • [49] Transformer hot-spot probes optimize loading, economics
    Electrical World, 1998, 212 (02):
  • [50] DISCUSSION OF SUBSTATION EXPANSION RELIABILITY AND TRANSFORMER LOADING POLICY ANALYSIS
    OLSSON, RA
    MONTMEAT, FE
    SVERAK, J
    GULACHEN.EM
    OSSMAN, WR
    WOODLEY, NH
    CRAFT, RC
    MILLER, RH
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1969, PA88 (08): : 1203 - &