Relative roles of microdamage and microfracture in the mechanical behavior of trabecular bone

被引:68
|
作者
Yeh, OC
Keaveny, TM
机构
[1] Univ Calif Berkeley, Dept Mech Engn, Orthopaed Biomech Lab, Berkeley, CA 94720 USA
[2] Univ Calif San Francisco, Dept Orthopaed Surg, San Francisco, CA 94143 USA
[3] Univ Calif Berkeley, Dept Bioengn, Berkeley, CA 94720 USA
关键词
D O I
10.1016/S0736-0266(01)00053-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Compared to trabecular microfracture, the biomechanical consequences of the morphologically more subtle trabecular microdamage are unclear but potentially important because of its higher incidence. A generic three-dimensional finite element model of the trabecular bone microstructure was used to investigate the relative biomechanical roles of these damage categories on reloading elastic modulus after simulated overloads to various strain levels. Microfractures of individual trabeculae were modeled using a maximum fracture strain criterion, for three values of fracture strain (2%, 8%, and 35%). Microdamage within the trabeculae was modeled using a strain-based modulus reduction rule based on cortical bone behavior. When combining the effects of both microdamage and microfracture, the model predicted reductions in apparent modulus upon reloading of over 60% at an applied apparent strain of 2%, in excellent agreement with previously reported experimental data. According to the model, up to 80% of the trabeculae developed microdamage at 2% apparent strain, and between 2% and 10% of the trabeculae were fractured, depending on which fracture strain was assumed. If microdamage could not occur but microfracture could, good agreement with the experimental data only resulted if the trabecular hard tissue had a fracture strain of 2%. However, a high number of fractures (10% of the trabeculae) would need to occur for this case, and this has not been observed in published damage morphology studies. We conclude therefore that if the damage behavior of trabecular hard tissue is similar to that of cortical bone, then extensive microdamage is primarily responsible for the large loss in apparent mechanical properties that can occur with overloading of trabecular bone. (C) 2001 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1001 / 1007
页数:7
相关论文
共 50 条
  • [21] Age-related differences in the morphology of microdamage propagation in trabecular bone
    Green, Jessica O.
    Wang, Jason
    Diab, Tamim
    Vidakovic, Brani
    Guldberg, Robert E.
    JOURNAL OF BIOMECHANICS, 2011, 44 (15) : 2659 - 2666
  • [22] The microdamage accumulation is more frequent in patients with impaired trabecular bone microstructure
    Pavo, J.
    Stepan, J. J.
    Li, J.
    Michalska, D.
    Sipos, A.
    Petto, H.
    Burr, D. B.
    Dobnig, H.
    CALCIFIED TISSUE INTERNATIONAL, 2007, 80 : S141 - S141
  • [23] The Effect of Specimen Geometry on the Mechanical Behavior of Trabecular Bone Specimens
    Ang, B. L. S.
    Tan, Y. J.
    Ng, Y. J. P.
    Ong, S. H. F.
    Yap, S. Y.
    Gwee, S. X.
    Chou, S. M.
    Poh, C. L.
    Yew, K. S.
    ADVANCED STRUCTURAL AND FUNCTIONAL MATERIALS FOR PROTECTION, 2012, 185 : 129 - +
  • [24] On the effect of marrow in the mechanical behavior and crush response of trabecular bone
    Halgrin, J.
    Chaari, F.
    Markiewicz, E.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 5 (01) : 231 - 237
  • [25] Methodology for Numerical Simulation of Trabecular Bone Structures Mechanical Behavior
    Argenta, M. A.
    Gebert, A. P.
    Filho, E. S.
    Felizari, B. A.
    Hecke, M. B.
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2011, 79 (3-4): : 159 - 182
  • [26] THE EFFECT OF CONSTRAINT ON THE MECHANICAL-BEHAVIOR OF TRABECULAR BONE SPECIMENS
    LINDE, F
    HVID, I
    JOURNAL OF BIOMECHANICS, 1989, 22 (05) : 485 - 490
  • [27] Prediction of Trabecular Level Microdamage and Bone Fracture Through Local Strain.
    Thurner, P. J.
    Jungmann, R.
    Tang, R.
    Schitter, G.
    Vashishth, D.
    Hansma, P. K.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2008, 23 : S362 - S362
  • [28] Methodological approach for the detection of both microdamage and fluorochrome labels in ewe bone and human trabecular bone
    Burt-Pichat, Brigitte
    Follet, Helene
    Toulemonde, Gwendoline
    Arlot, Monique
    Delmas, Pierre
    Chapurlat, Roland
    JOURNAL OF BONE AND MINERAL METABOLISM, 2011, 29 (06) : 756 - 764
  • [29] Methodological approach for the detection of both microdamage and fluorochrome labels in ewe bone and human trabecular bone
    Brigitte Burt-Pichat
    Hélène Follet
    Gwendoline Toulemonde
    Monique Arlot
    Pierre Delmas
    Roland Chapurlat
    Journal of Bone and Mineral Metabolism, 2011, 29 : 756 - 764
  • [30] High-speed photography of the development of microdamage in trabecular bone during compression
    Thurner, Philipp J.
    Erickson, Blake
    Schriock, Zachary
    Langan, John
    Scott, Jeff
    Zhao, Maria
    Weaver, James C.
    Fantner, Georg E.
    Turner, Patricia
    Kindt, Johannes H.
    Schitter, Georg
    Morse, Daniel E.
    Hansma, Paul K.
    JOURNAL OF MATERIALS RESEARCH, 2006, 21 (05) : 1093 - 1100