Shear response of concrete-filled FRP composite cylindrical shells

被引:13
|
作者
Burgueño, R
Bhide, KM
机构
[1] Michigan State Univ, Dept Civil & Environm Engn, E Lansing, MI 48824 USA
[2] Engn Serv & Consultants Inc, Youngstown, OH 44503 USA
来源
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | 2006年 / 132卷 / 06期
关键词
D O I
10.1061/(ASCE)0733-9445(2006)132:6(949)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an analytical procedure for predicting the shear load-deformation response of concrete filled fiber-reinforced polymer (FRP) composite cylindrical shells with full- and noncomposite behavior. The approach is based on a sectional layered analysis with an iterative algorithm to achieve equilibrium and compatibility conditions of the FRP/concrete system, including the cracked behavior of the FRP-confined concrete, until first-ply failure of the FRP composite. The model follows first order mechanics for the shear behavior of structural members in combination with a smeared shear modulus for cracked concrete and inclusion of extension/shear coupling effects of anisotropic FRP laminates. Comparisons of the analytical response with available experimental data from large- and small-scale tests were found to be in reasonable agreement and corroborated the significant influence of the concrete core and the composite interaction details on the shear load-deformation response. Parametric studies on the influence of concrete properties, axial loads, and FRP laminate design are discussed.
引用
收藏
页码:949 / 960
页数:12
相关论文
共 50 条
  • [41] Compressive performance of concrete-filled steel tube columns with in-built seawater and sea sand concrete-filled FRP tubes
    Wei, Yang
    Zhu, Chao
    Miao, Kunting
    Zheng, Kaiqi
    Tang, Yu
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 317
  • [42] Behavior of Hollow and Concrete-Filled FRP-HSC and FRP-HSC-Steel Composite Columns Subjected to Concentric Compression
    Fanggi, B. A. Louk
    Ozbakkaloglu, T.
    ADVANCES IN STRUCTURAL ENGINEERING, 2015, 18 (05) : 715 - 738
  • [43] Principles and analysis of concrete-filled composite tubes
    Mirmiran, A
    Naguib, W
    Shahawy, M
    JOURNAL OF ADVANCED MATERIALS, 2000, 32 (04): : 16 - 23
  • [44] Behavior of concrete-filled FRP tube columns internally reinforced with FRP-steel composite bars under axial compression
    Guo, Yong-Chang
    Xiao, Shu-Hua
    Zeng, Jun-Jie
    Su, Jia-Ying
    Li, Tian-Zi
    Xie, Zhi-Hong
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 315
  • [45] Principles and analysis of concrete-filled composite tubes
    Mirmiran, Amir
    Naguib, Wassim
    Shahawy, Mohsen
    2000, Soc. for the Advancement of Material and Process Engineering, Covina, CA, USA (32):
  • [46] Beam-column behaviour of concrete-filled circular FRP tubes
    Flisak, B
    Fam, AZ
    Rizkalla, SH
    COMPOSITES IN CONSTRUCTION, 2001, : 785 - 789
  • [47] Concrete-filled square and rectangular FRP tubes under axial compression
    Ozbakkaloglu, Togay
    Oehlers, Deric J.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2008, 12 (04) : 469 - 477
  • [48] COMPRESSIVE BEHAVIOR OF STEEL FIBER REINFORCED CONCRETE-FILLED FRP TUBES
    Xie, Tianyu
    Ozbakkaloglu, Togay
    PROCEEDINGS OF THE THIRTEENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOLS 1 AND II, 2014, : 48 - 55
  • [49] Behavior of FRP-Confined Concrete-Filled Steel Tube Columns
    Lu, Yiyan
    Li, Na
    Li, Shan
    POLYMERS, 2014, 6 (05): : 1333 - 1349
  • [50] Experimental Investigation on the Impact Performance of Concrete-Filled FRP Steel Tubes
    Chen, Chen
    Zhao, Yinghua
    Li, Jackie
    JOURNAL OF ENGINEERING MECHANICS, 2015, 141 (02)