Interactive Initialization for 2D/3D Intra-Operative Registration using the Microsoft Kinect

被引:1
|
作者
Gong, Ren Hui [1 ]
Gueler, Oezgur [1 ]
Yaniv, Ziv [1 ]
机构
[1] Childrens Natl Med Ctr, Sheikh Zayed Inst Pediat Surg Innovat, Washington, DC 20010 USA
关键词
image-guided therapy; registration initialization; human computer interface; Microsoft Kinect;
D O I
10.1117/12.2008525
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
All 2D/3D anatomy based rigid registration algorithms are iterative, requiring an initial estimate of the 3D data pose. Current initialization methods have limited applicability in the operating room setting, due to the constraints imposed by this environment or due to insufficient accuracy. In this work we use the Microsoft Kinect device to allow the surgeon to interactively initialize the registration process. A Kinect sensor is used to simulate the mouse-based operations in a conventional manual initialization approach, obviating the need for physical contact with an input device. Different gestures from both arms are detected from the sensor in order to set or switch the required working contexts. 3D hand motion provides the six degree-of-freedom controls for manipulating the pre-operative data in the 3D space. We evaluated our method for both X-ray/CT and X-ray/MR initialization using three publicly available reference data sets. Results show that, with initial target registration errors of 117.7 +/- 28.9 mm a user is able to achieve final errors of 5.9 +/- 2.6 mm within 158 +/- 65 sec using the Kinect-based approach, compared to 4.8 +/- 2.0 mm and 88 +/- 60 sec when using the mouse for interaction. Based on these results we conclude that this method is sufficiently accurate for initialization of X-ray/CT and X-ray/MR registration in the OR.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Semantic Monocular Surgical SLAM: Intra-Operative 3D Reconstruction and Pre-operative Registration in Dynamic Environments
    Roberti, Andrea
    Meli, Daniele
    De Rossi, Giacomo
    Muradore, Riccardo
    Fiorini, Paolo
    2023 21ST INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS, ICAR, 2023, : 486 - 491
  • [22] Computation of DRRs using 3D texture mapping for 2D/3D registration
    Kim, SM
    Kim, YS
    CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 1313 - 1313
  • [23] 2D/3D image registration using regression learning
    Chou, Chen-Rui
    Frederick, Brandon
    Mageras, Gig
    Chang, Sha
    Pizer, Stephen
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2013, 117 (09) : 1095 - 1106
  • [24] Robust 2D/3D Calibration Using RANSAC Registration
    Fortenbury, Billy Ray
    Guerra-Filho, Gutemberg
    ADVANCES IN VISUAL COMPUTING, ISVC 2012, PT I, 2012, 7431 : 179 - 188
  • [25] Kinematic registration in 3D using the 2D Reuleaux method
    Eberharter, JK
    Ravani, B
    JOURNAL OF MECHANICAL DESIGN, 2006, 128 (02) : 349 - 355
  • [26] 2D/3D deformable registration using a hybrid atlas
    Tang, TSY
    Ellis, RE
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 2, 2005, 3750 : 223 - 230
  • [27] Endoscopic navigation system using 2D/3D registration
    Hummel, Johann
    Figl, Michael
    Bergmann, Helmar
    Birkfellner, Wolfgang
    MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [28] Registration Using Nanotube Stationary Tomosynthesis: Comparison of 3D/3D to 3D/2D Methods
    Frederick, B.
    Lalush, D.
    Chang, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [29] Intra-operative visualisation of 3D temperature maps and 3D navigation during tissue cryoablation
    Samset, E
    Mala, T
    Aurdal, L
    Balasingham, I
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2005, 29 (06) : 499 - 505
  • [30] 2D/3D registration of multiple bones
    Ma, Burton
    Stewart, James
    Pichora, David
    Ellis, Randy
    Abolmaesumi, Purang
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 860 - 863