Neutral analyte focusing by micelle collapse in micellar electrokinetic chromatography

被引:49
|
作者
Quirino, Joselito P. [1 ]
机构
[1] Univ Tasmania, Sch Chem, Australian Ctr Res Separat Sci, Hobart, Tas 7001, Australia
关键词
On-line sample preconcentration; Normal migration micellar electrokinetic chromatography; Analyte focusing by micelle collapse; Neutral analyzes; Isotachophoresis;
D O I
10.1016/j.chroma.2008.10.074
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The operating parameters that affect the performance of analyte focusing by micelle collapse (AFMC) to neutral analyzes (i.e dialkyl phthalates) in normal migration micellar electrokinetic chromatography (NM-MEKC) are examined. NM-MEKC is characterized by an electroosmotic flow greater than the electrophoretic velocity of the micellar pseudostationary phase, and was performed using sodium dodecyl sulfate (SDS) with neutral to high pH electrolytes in fused silica capillaries. AFMC is a recently introduced on-line sample preconcentration technique in capillary electrophoresis that can provide hundreds fold improvement in detection sensitivity. The mechanism of AFMC is based on the analyte transport, release, and accumulation by the moving surfactant micelles [e.g., SDS at concentrations closer to the critical micelle concentration (CMC)] in the sample that dilutes below its CIVIC into a liquid phase zone. The sample is prepared in a matrix that contains SDS micelles and high mobility anions, where the conductivity of the sample matrix is higher compared to that of the separation solution. The sample injection length, sample and separation solution conductivity ratio, and surfactant micelle concentration in the sample were found to affect the AFMC performance, as well as the effective separation length in NM-MEKC. The use of a different electrolyte salt in the sample and separation solution also affected AFMC NM-MEKC results. In particular, sodium chloride in the sample matrix can induce a micelle-mediated neutral analyte isotachophoretic concentration that is detrimental to the technique. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:171 / 177
页数:7
相关论文
共 50 条
  • [41] Comparison of chiral micelle polymers for chiral separation by micellar electrokinetic capillary chromatography.
    Williams, CC
    Alexander, T
    Dey, J
    Shamsi, S
    Warner, IM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 211 : 61 - ANYL
  • [42] Micellar electrokinetic chromatography: A review of methodological and instrumental innovations focusing on practical aspects
    Silva, Manuel
    ELECTROPHORESIS, 2013, 34 (01) : 141 - 158
  • [43] Sweeping of analyte zones in electrokinetic chromatography
    Quirino, JP
    Terabe, S
    ANALYTICAL CHEMISTRY, 1999, 71 (08) : 1638 - 1644
  • [44] MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY
    SEPANIAK, MJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1986, 191 : 112 - ANYL
  • [45] OPTIMIZATION OF MICELLAR ELECTROKINETIC CHROMATOGRAPHY
    FOLEY, JP
    ANALYTICAL CHEMISTRY, 1990, 62 (13) : 1302 - 1308
  • [46] Characterisation of retention in micellar high-performance liquid chromatography, in micellar electrokinetic chromatography and in micellar electrokinetic chromatography with reduced flow
    Jandera, P
    Fischer, J
    Jebavá, J
    Effenberger, H
    JOURNAL OF CHROMATOGRAPHY A, 2001, 914 (1-2) : 233 - 244
  • [47] Chiral Micellar Electrokinetic Chromatography
    Salido-Fortuna, Sandra
    Castro-Puyana, Maria
    Luisa Marina, Maria
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1626
  • [48] Micellar electrokinetic chromatography of proteins
    Strege, MA
    Lagu, AL
    JOURNAL OF CHROMATOGRAPHY A, 1997, 780 (1-2) : 285 - 296
  • [49] Dispersion in micellar electrokinetic chromatography
    Davis, JM
    ADVANCES IN CHROMATOGRAPHY, VOL 40, 2000, 40 : 115 - 157
  • [50] MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY
    SEPANIAK, MJ
    BURTON, DE
    MASKARINEC, MP
    ACS SYMPOSIUM SERIES, 1987, 342 : 142 - 151