Study on Dual-Energy Signal and Noise of Double-Exposure X-Ray Imaging for High Conspicuity

被引:1
|
作者
Song, Boram [1 ]
Kim, Changsoo [2 ]
Kim, Junwoo [3 ]
机构
[1] Inje Univ, Haeundae Paik Hosp, Dept Radiol, Coll Med, Busan, South Korea
[2] Catholic Univ Pusan, Coll Hlth Sci, Dept Radiol Sci, Busan, South Korea
[3] Pusan Natl Univ, Ctr Adv Med Engn Res, 2 Busandaehak Ro 63beon Gil, Busan 46241, South Korea
来源
基金
新加坡国家研究基金会;
关键词
Dual-Energy X-Ray Imaging; Modulation Transfer Function; Noise Power Spectrum; NEQ; Noise Reduction; OPTIMIZATION; ALGORITHM; SYSTEM;
D O I
10.14407/jrpr.2021.00017
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Background: Dual-energy X-ray images (DEI) can distinguish or improve materials of interest in a two-dimensional radiographic image, by combining two images obtained from separate low and high energies. The concepts of DEI performance describing the performance of double-exposure DEI systems in the Fourier domain been previously introduced, however, the performance of double-exposure DEI itself in terms of various parameters, has not been reported. Materials and Methods: To investigate the DEI performance, signal-difference-to-noise ratio, modulation transfer function, noise power spectrum, and noise equivalent quanta were used. Low- and high-energy were 60 and 130 kVp with 0.01-0.09 mGy, respectively. The energy-separation filter material and its thicknesses were tin (Sn) and 0.0-1.0 mm, respectively. Noise-reduction (NR) filtering used the Gaussian-filter NR, median-filter NR, and anti-correlated NR. Results and Discussion: DEI performance was affected by Sn-filter thickness, weighting factor, and dose allocation. All NR filtering successfully reduced noise, when compared with the dual-energy (DE) images without any NR filtering. Conclusion: The results indicated the significance of investigating, and evaluating suitable DEI performance, for DE images in chest radiography applications. Additionally, all the NR filtering methods were effective at reducing noise in the resultant DE images.
引用
收藏
页码:160 / 169
页数:10
相关论文
共 50 条
  • [21] Detective quantum efficiency of a double-layered detector for dual-energy x-ray imaging
    Shin, Hubeom
    Yoo, Seungjun
    Oh, Seokwon
    Lee, Junho
    Kyung, Ho
    JOURNAL OF INSTRUMENTATION, 2023, 18 (11)
  • [22] Dual-Energy X-ray Medical Imaging with Inverse Compton Sources: A Simulation Study
    Paterno, Gianfranco
    Cardarelli, Paolo
    Gambaccini, Mauro
    Taibi, Angelo
    CRYSTALS, 2020, 10 (09): : 1 - 21
  • [23] Robust Material Classification on Dual-Energy X-Ray Imaging Devices
    Cigla, Cevahir
    Kucukates, Busra
    Yalcin, Ozan
    Ak, Duygu Selin
    Isikoglu, Sukrucan Taylan
    ANOMALY DETECTION AND IMAGING WITH X-RAYS (ADIX) VII, 2022, 12104
  • [24] Evaluation of a dichromatic X-ray source for dual-energy imaging in mammography
    Tuffanelli, A
    Fabbri, S
    Sarnelli, A
    Taibi, A
    Gambaccini, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 489 (1-3): : 509 - 518
  • [25] Theoretical Feasibility of Dual-Energy X-Ray Imaging of Respiratory Disease
    Basharat, F.
    Tanguay, J.
    MEDICAL PHYSICS, 2020, 47 (06) : E558 - E558
  • [26] Stereoscopic dual-energy X-ray imaging for target materials identification
    Wang, TW
    Evans, JPO
    IEE PROCEEDINGS-VISION IMAGE AND SIGNAL PROCESSING, 2003, 150 (02): : 122 - 130
  • [27] Image segmentation for binocular stereoscopic dual-energy x-ray imaging
    Yong, YS
    Evans, JPO
    Chan, JW
    JOURNAL OF ELECTRONIC IMAGING, 2005, 14 (04)
  • [28] Dual-energy medical X-ray imaging using LaPlace transformation
    Tang, SJ
    Mou, XQ
    Yang, Y
    Luo, T
    Cai, YL
    METMBS '05: PROCEEDINGS OF THE 2005 INTERNATIONAL CONFERENCE ON MATHEMATICS AND ENGINEERING TECHNIQUES IN MEDICINE AND BIOLOGICAL SCIENCES, 2005, : 117 - 123
  • [29] Adaptive noise reduction for dual-energy x-ray imaging based on spatial variations in beam attenuation
    Romadanov, Ivan
    Sattarivand, Mike
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24):
  • [30] Dual-Energy X-ray Imaging by Simultaneous Integration and Campbelling Readout
    Roessl, Ewald
    Thran, Axel
    Martens, Gerhard
    Istel, Thomas
    Proksa, Roland
    Schlomka, Jens-Peter