Determination of Percent Hemoglobin A1c Using a Potentiometric Method

被引:31
|
作者
Liu, Hong [1 ]
Crooks, Richard M. [1 ]
机构
[1] Univ Texas Austin, Dept Chem & Biochem, Austin, TX 78712 USA
关键词
ALIZARIN RED S; GLYCATED HEMOGLOBIN; DIABETES-MELLITUS; ASSAY; GLYCOHEMOGLOBIN; CHROMATOGRAPHY; BLOOD; A(1C);
D O I
10.1021/ac3032228
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report a potentiometric method for measuring the hemoglobin A1c (HbA1c, glycated hemoglobin) concentration, hemoglobin (Hb) concentration, and percent HbA1c (%HbAlc) in human blood hemolysate. The %HbAlc is important for diagnosis and management of diabetes mellitus. Alizarin red s (ARS) is used as a redox indicator. Phenylboronic acid (PBA) binds to both ABS and HbA1c via diol boronic acid complexation. The binding of PBA to ARS shifts its redox potential negatively. However, when HbA1c competes with ARS for PBA binding, the solution potential shifts positively. This shift is linked to the HbA1c concentration. The concentration of Hb is determined by allowing it to react with Fe(CN)(6)(3-). The potential shift arising from the reduction of Fe(CN)(6)(3-) by Hb is proportional to the logarithm of the Hb concentration. The results obtained for %HbAlc in human blood hemolysate are in good agreement with those determined using a reference method.
引用
收藏
页码:1834 / 1839
页数:6
相关论文
共 50 条
  • [21] Interference of Hemoglobin Variants in the Measurement of Hemoglobin A1c
    Kurt, Yasemin Gulcan
    Cayci, Tuncer
    Akgul, E. Ozgur
    Aydin, Ibrahim
    Aydin, Fevzi N.
    Agilli, Mehmet
    Yaman, Halil
    Cakir, Erdinc
    Yasar, Mehmet
    Bilgi, Cumhur
    Erbil, M. Kemal
    TURKISH JOURNAL OF BIOCHEMISTRY-TURK BIYOKIMYA DERGISI, 2010, 35 (03): : 262 - 267
  • [22] Interference of the Hope Hemoglobin With Hemoglobin A1c Results
    Chakraborty, Sutirtha
    Chanda, Dalia
    Gain, Mithun
    Krishnan, Prasad
    LABMEDICINE, 2015, 46 (03): : 221 - 225
  • [23] ON QUATERNARY STRUCTURE OF HEMOGLOBIN A1C
    EFREMOV, GD
    HUISMAN, THJ
    BIOCHIMICA ET BIOPHYSICA ACTA, 1969, 194 (02) : 609 - &
  • [24] HEMOGLOBIN A1C REPRODUCIBILITY - REPLY
    SOELDNER, JS
    GLEASON, RE
    ANNALS OF INTERNAL MEDICINE, 1980, 92 (04) : 574 - 574
  • [25] IN VITRO BIOSYNTHESIS OF HEMOGLOBIN A1C
    HOLMQUIST, WR
    SCHROEDER, WA
    BIOCHEMISTRY, 1966, 5 (08) : 2504 - +
  • [26] The Highs and Lows of Hemoglobin A1c
    Lavis, Victor R.
    CARDIOLOGY, 2016, 134 (03) : 325 - 326
  • [27] Problems with measurements of hemoglobin A1c
    Smith, Steven A.
    Montori, Victor M.
    Isley, William L.
    Burritt, Mary F.
    MAYO CLINIC PROCEEDINGS, 2006, 81 (08) : 1130 - 1130
  • [28] Interpretation of Hemoglobin A1c Values
    Sacks, David B.
    John, W. Garry
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 311 (22): : 2271 - 2272
  • [29] Implications of Using Hemoglobin A1C for Diagnosing Diabetes Mellitus
    Malkani, Samir
    Mordes, John P.
    AMERICAN JOURNAL OF MEDICINE, 2011, 124 (05): : 395 - 401
  • [30] Hemoglobin A1c Measurement Using Point of Care Testing
    Erdal, Gulcin Sahingoz
    Isiksacan, Nilgun
    Koser, Murat
    Kocamaz, Nursel
    ISTANBUL MEDICAL JOURNAL, 2020, 21 (01): : 37 - 41