Determination of Percent Hemoglobin A1c Using a Potentiometric Method

被引:31
|
作者
Liu, Hong [1 ]
Crooks, Richard M. [1 ]
机构
[1] Univ Texas Austin, Dept Chem & Biochem, Austin, TX 78712 USA
关键词
ALIZARIN RED S; GLYCATED HEMOGLOBIN; DIABETES-MELLITUS; ASSAY; GLYCOHEMOGLOBIN; CHROMATOGRAPHY; BLOOD; A(1C);
D O I
10.1021/ac3032228
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report a potentiometric method for measuring the hemoglobin A1c (HbA1c, glycated hemoglobin) concentration, hemoglobin (Hb) concentration, and percent HbA1c (%HbAlc) in human blood hemolysate. The %HbAlc is important for diagnosis and management of diabetes mellitus. Alizarin red s (ARS) is used as a redox indicator. Phenylboronic acid (PBA) binds to both ABS and HbA1c via diol boronic acid complexation. The binding of PBA to ARS shifts its redox potential negatively. However, when HbA1c competes with ARS for PBA binding, the solution potential shifts positively. This shift is linked to the HbA1c concentration. The concentration of Hb is determined by allowing it to react with Fe(CN)(6)(3-). The potential shift arising from the reduction of Fe(CN)(6)(3-) by Hb is proportional to the logarithm of the Hb concentration. The results obtained for %HbAlc in human blood hemolysate are in good agreement with those determined using a reference method.
引用
收藏
页码:1834 / 1839
页数:6
相关论文
共 50 条
  • [1] Interference with hemoglobin A1c determination by the hemoglobin variant shelby
    Scuderi, Richard T.
    Griffin, Terrance L.
    Mehta, Shruti P.
    Herold, David A.
    Fitzgerald, Robert L.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2007, 128 (03) : 440 - 444
  • [2] DETERMINATION OF HEMOGLOBIN A1C BY LIQUID-CHROMATOGRAPHY
    PANULAONTTO, R
    GUSTAFSSON, S
    CLINICAL CHEMISTRY, 1988, 34 (01) : 210 - 210
  • [3] Fabrication of a biochip for percent hemoglobin A1c (%HbA1c) level measurement
    Son, SU
    Seo, JH
    Choi, YH
    Lee, SS
    Kang, SJ
    Transducers '05, Digest of Technical Papers, Vols 1 and 2, 2005, : 1752 - 1755
  • [4] FAST AND ACCURATE DETERMINATION OF HEMOGLOBIN A1C USING AN AUTOMATED SAMPLE PROCESSOR
    DUTRIEU, J
    DELMOTTE, YA
    DELANNOY, P
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 321 (02): : 180 - 184
  • [5] AN APPLICATION TO THE MEASUREMENT OF RAT HEMOGLOBIN A1C BY NEW HEMOGLOBIN A1C IMMUNOASSAY METHOD (DCA-2000))
    ITO, Y
    KAWAZU, S
    TOMONO, S
    SHIMIZU, M
    OHNO, T
    KATO, N
    ISHII, T
    MURATA, K
    HORMONE AND METABOLIC RESEARCH, 1994, 26 (12) : 615 - 616
  • [6] Comparison of costs of hemoglobin A1c determination by point-of-care testing (POCT) and standard hemoglobin A1c analyzer
    Wiwanitkit, V.
    ARCHIVES OF HELLENIC MEDICINE, 2010, 27 (06): : 953 - 955
  • [7] Availability of an immunoassay for the determination of glycated hemoglobin (Hb A1c): Influence of hemoglobin variant on Hb A1c values.
    Harano, T
    Harano, K
    Doi, K
    Yoshikawa, K
    Kamada, S
    Mochizuki, K
    Saitoh, H
    CLINICAL CHEMISTRY, 1998, 44 : A27 - A27
  • [8] Components of total measurement error for hemoglobin A1c determination
    Phillipov, G
    Phillips, PJ
    CLINICAL CHEMISTRY, 2001, 47 (10) : 1851 - 1853
  • [9] Standardization of hemoglobin A1c
    Johnson, R
    CLINICAL CHEMISTRY, 1998, 44 (05) : 1068 - 1068
  • [10] Significance of hemoglobin A1c
    Purucker, E
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2001, 126 (20) : 608 - 609