3D-Double-Inversion Recovery detects perilesional gliosis better than 3D-FLAIR and postcontrast T1 imaging in calcified neurocysticercosis

被引:6
|
作者
Saini, Jitender [1 ]
Gupta, Pradeep Kumar [3 ]
Gupta, Praveen [4 ]
Yadav, Ravi [2 ]
Yadav, Nishtha [1 ]
Gupta, Rakesh Kumar [3 ]
机构
[1] Natl Inst Mental Hlth & Neurosci, Dept Neuroimaging & Intervent Radiol, Bengaluru, Karnataka, India
[2] Natl Inst Mental Hlth & Neurosci, Dept Neurol, Bengaluru, Karnataka, India
[3] Fortis Mem Res Inst, Dept Radiol & Imaging, Gurugram 122002, Haryana, India
[4] Fortis Mem Res Inst, Dept Neurol, Gurugram, Haryana, India
关键词
Brain; double-inversion recovery; fluid attenuating inversion recovery imaging; neurocysticercosis; perilesional gliosis; seizures; LESIONS; SEIZURES; EPILEPSY; MRI;
D O I
10.4103/0028-3886.253614
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Perilesional gliosis is an important substrate for seizures in patients harboring a calcified neurocysticercosis (NCC) lesion and magnetic resonance imaging (MRI) is useful for evaluating gliosis. Aims: The purpose of this study was to evaluate the usefulness of double-inversion recovery (DIR) sequence for identifying perilesional gliosis. Settings and Design: Hospital-based cross-sectional study. Methods and Materials: Forty-five patients with seizures were included in this study and a total of 88 calcified lesions identified on susceptibility weighted imaging (SWI) were evaluated on 3D-fluid attenuating inversion recovery (FLAIR), 3D-DIR, and 3D-postcontrast T1-weighted imaging on a 3T MRI for the presence of perilesional signal changes/enhancement. Perilesional signal was rated on a semiquantitative scale from grade 0 to 2 by independent raters. Statistical Analysis Used: Friedman, Wilcoxon signed rank, and Kappa tests were used. Results: 3D-DIR sequence performed better than both 3D-FLAIR and postcontrast 3D-T1W sequences as more number of lesions showed perilesional signal change on DIR sequence. DIR sequence showed perilesional signal abnormality in 24 lesions in which 3D-FLAIR was normal, whereas in another 18 lesions, it demonstrated perilesional signal changes better than 3D-FLAIR. In only three lesions, FLAIR was found to be superior to DIR sequence, whereas postcontrast T1W images showed rim enhancement in five cases where no perilesional signal change was seen on FLAIR/DIR sequences. Conclusions: Combining 3D-DIR with 3D-FLAIR, and postcontrast 3D-T1W sequences is beneficial for evaluation of calcified NCC lesions and 3D-DIR sequence is better than other two sequences for perilesional signal abnormalities.
引用
收藏
页码:136 / 141
页数:6
相关论文
共 50 条
  • [31] Simultaneous T1 and T2 mapping of the carotid plaque (SIMPLE) with T2 and inversion recovery prepared 3D radial imaging
    Qi, Haikun
    Sun, Jie
    Qiao, Huiyu
    Zhao, Xihai
    Guo, Rui
    Balu, Niranjan
    Yuan, Chun
    Chen, Huijun
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (06) : 2598 - 2608
  • [32] Population-based prevalence of infarctions on 3D fluid-attenuated inversion recovery (FLAIR) imaging
    Cogswell, Petrice M.
    Aakre, Jeremiah A.
    Castillo, Anna M.
    Knopman, David S.
    Kantarci, Kejal
    Rabinstein, Alejandro A.
    Petersen, Ronald C.
    Clifford, R. Jack, Jr.
    Mielke, Michelle M.
    Vemuri, Prashanthi
    Graff-Radford, Jonathan
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2022, 31 (08):
  • [33] 3D myocardial T1 mapping using saturation recovery
    Nordio, Giovanna
    Henningsson, Markus
    Chiribiri, Amedeo
    Villa, Adriana D. M.
    Schneider, Torben
    Botnar, Rene M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (01) : 218 - 227
  • [34] T1 measurement of bound water in cortical bone using 3D adiabatic inversion recovery ultrashort echo time (3D IR-UTE) Cones imaging
    Guo, Tan
    Ma, Yajun
    Jerban, Saeed
    Jang, Hyungseok
    Zhao, Wei
    Chang, Eric Y.
    Chen, Min
    Bydder, Graeme M.
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 634 - 645
  • [35] Qualitative and quantitative analysis of 3D T1 Silent imaging
    Francesca Di Giuliano
    Silvia Minosse
    Eliseo Picchi
    Valentina Ferrazzoli
    Valerio Da Ros
    Massimo Muto
    Chiara Adriana Pistolese
    Francesco Garaci
    Roberto Floris
    La radiologia medica, 2021, 126 : 1207 - 1215
  • [36] Qualitative and quantitative analysis of 3D T1 Silent imaging
    Francesca, Di Giuliano
    Silvia, Minosse
    Eliseo, Picchi
    Valentina, Ferrazzoli
    Valerio, Da Ros
    Massimo, Muto
    Adriana, Pistolese Chiara
    Francesco, Garaci
    Roberto, Floris
    RADIOLOGIA MEDICA, 2021, 126 (09): : 1207 - 1215
  • [37] MR Imaging in Multiple Sclerosis: The Accuracy of 3D Double Inversion Recovery at 3 Tesla and the Potential for Single Sequence Imaging
    Khangure, S. R.
    Khangure, M. S.
    NEURORADIOLOGY JOURNAL, 2011, 24 (01): : 92 - 99
  • [38] T1 mapping from routine 3D T1-weighted inversion recovery sequences in clinical practice: comparison against reference inversion recovery fast field echo T1 scans and feasibility in multiple sclerosis
    Young, Griffin
    Nguyen, Vivian S.
    Howlett-Prieto, Quentin
    Abuaf, Amanda Frisosky
    Carroll, Timothy J.
    Kawaji, Keigo
    Javed, Adil
    NEURORADIOLOGY, 2024, 66 (10) : 1709 - 1719
  • [39] Estimation of Gadolinium-induced T1-shortening with Measurement of Simple Signal Intensity Ratio between the Cochlea and Brain Parenchyma on 3D-FLAIR: Correlation with T1 Measurement by TI Scout Sequence
    Naganawa, Shinji
    Ishihara, Shunichi
    Iwano, Shingo
    Kawai, Hisashi
    Sone, Michihiko
    Nakashima, Tsutomu
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2010, 9 (01) : 17 - 22
  • [40] SAR and scan-time optimized 3D whole-brain double inversion recovery imaging at 7T
    Pracht, Eberhard D.
    Feiweier, Thorsten
    Ehses, Philipp
    Brenner, Daniel
    Roebroeck, Alard
    Weber, Bernd
    Stoecker, Tony
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (05) : 2620 - 2628