The detection of carbon dioxide embolism during laparoscopy in pigs: A comparison of transesophageal Doppler and end-tidal carbon dioxide monitoring

被引:18
|
作者
Mann, C [1 ]
Boccara, G [1 ]
Fabre, JM [1 ]
Grevy, V [1 ]
Colson, P [1 ]
机构
[1] HOP ST ELOI,EXPT SURG LAB,F-34295 MONTPELLIER,FRANCE
关键词
capnography; carbon dioxide; gaseous embolism; laparoscopy; transesophageal Doppler;
D O I
10.1111/j.1399-6576.1997.tb04680.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The aim of the study was to compare the value of transesophageal Doppler and end-tidal carbon dioxide monitoring to detect venous carbon dioxide embolism in pigs during laparoscopic cholecystectomy. Method: Ten pigs were anesthetized under constant ventilation, and instrumented for laparoscopic cholecystectomy. CO2 pneumoperitoneum was performed at 15 mmHg and then, successive increased intravenous gas boluses of 0.1 to 4 ml/kg injected through the femoral vein using a 55-mm long catheter. The responses indicative of embolism were defined as: 1) a change in Doppler tone placed facing the junction of the right atrium and inferior vena cava; 2) a change in end-tidal CO2 greater than or equal to 0.4 kPa. Results: Doppler was more sensitive in detecting 0.1, 0.2 and 0.4 ml/mg of CO2 embolism than end-tidal CO2 (P<0.05). Over 0.4 ml/mg no differences in sensitivity were found but the Doppler signal modifications occurred earlier than the changes in end-tidal CO2. Moreover, these changes always consisted of a reduction of the value. Conclusion: During laparoscopic cholecystectomy in pigs, transesophageal Doppler was a highly sensitive monitor which provided an earlier detection of CO2 embolism and at lower doses than end-tidal CO2 monitoring. (C) Acta Anaesthesiologica Scandinavica 41 (1997).
引用
收藏
页码:281 / 286
页数:6
相关论文
共 50 条
  • [31] Assessment of End-Tidal Carbon Dioxide and Partial Pressure of Arterial Carbon Dioxide During an Endoscopic Procedure Using Carbon Dioxide
    Azemoto, Nobuaki
    Ninomiya, Tomoyuki
    Kumagi, Teru
    Michitaka, Kojiro
    GASTROINTESTINAL ENDOSCOPY, 2016, 83 (05) : AB540 - AB540
  • [32] The roll of end-tidal carbon dioxide in Ecpr
    Olander, Carl-Henrik
    Vikholm, Per
    Schiller, Petter
    Hellgren, Laila
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2019, 63 (08) : E3 - E3
  • [33] A bizarre end-tidal carbon dioxide waveform
    Apuya, JS
    Kanter, G
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2002, 49 (10): : 1098 - 1099
  • [34] More on epinephrine and end-tidal carbon dioxide
    Zeidan, A
    Nahle, N
    ANAESTHESIA, 2005, 60 (04) : 415 - 416
  • [35] The Effects Of Phonation On End-Tidal Carbon Dioxide
    Gillespie, A. I.
    Slivka, W.
    Atwood, C. W.
    Abbott, K. Verdolini
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [36] Monitoring of end tidal carbon dioxide and transcutaneous carbon dioxide during neonatal transport
    Tingay, DG
    Stewart, MJ
    Morley, CJ
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2005, 90 (06): : F523 - F526
  • [37] USE OF END-TIDAL CARBON DIOXIDE TO EXCLUDE PULMONARY EMBOLISM IN HOSPITALIZED ADULTS
    Prentice, Donna
    Wipke-Tevis, Deidre
    DeRoche, Chelsea
    CRITICAL CARE MEDICINE, 2019, 47
  • [38] Continuous End-Tidal Carbon Dioxide Monitoring during Resuscitation of Asphyxiated Term Lambs
    Chandrasekharan, Praveen Kumar
    Rawat, Munmun
    Nair, Jayasree
    Gugino, Sylvia F.
    Koenigsknecht, Carmon
    Swartz, Daniel D.
    Vali, Payam
    Mathew, Bobby
    Lakshminrusimha, Satyan
    NEONATOLOGY, 2016, 109 (04) : 265 - 273
  • [39] UTILITY OF END-TIDAL AND TRANSCUTANEOUS CARBON DIOXIDE MONITORING DURING LETHAL HEMORRHAGIC SHOCK
    Belenkiy, S.
    Berry, J.
    Batchinsky, A.
    Kendrick, C.
    Necsoiu, C.
    Salinas, J.
    Cancio, L.
    SHOCK, 2013, 39 : 44 - 45
  • [40] End-tidal carbon dioxide monitoring revealed severe complications during cardiothoracic surgery
    Qiu Yongsheng
    Xu Lei
    Jia Yingping
    儿科学研究(英文), 2019, 3 (01) : 58 - 59