Fingerprint Imaging System Based on Capacitive Micromachined Ultrasonic Transducer by Using Impediography Method Including Direct Touch and Waveguide Methods

被引:16
|
作者
Choi, Won Young [1 ]
Kwak, Yun Sang [1 ]
Park, Kwan Kyu [1 ]
机构
[1] Hanyang Univ, Dept Mech Convergence Engn, Seoul 04763, South Korea
基金
新加坡国家研究基金会;
关键词
Capacitive micromachined ultrasonic transducer (CMUT); direct touch; fingerprint imaging; impediography; waveguide; IDENTIFICATION; SURFACE;
D O I
10.1109/TUFFC.2018.2885788
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Fingerprint imaging is a powerful tool in biometric identification systems. This paper proposes a fingerprint imaging method that involves applying an impedance signal to a fingerprint via ultrasonic impediography using a capacitive micromachined ultrasonic transducer (CMUT). We fabricated CMUT sparse array which has a center frequency of 6.25 MHz and collapse voltage of 50 V by local oxidation of silicon process. We develop a prototype by using waveguide and ultrasonic impediography method based on the CMUT. By using a waveguide made from a hard material, the prototype can ensure device protection and image lateral resolution improvement. The proposed technique successfully images the acoustic input impedance differences between the ridges and valleys of a fingerprint. The images created using direct touch and waveguide models are compared and analyzed. In addition, we present a phenomenon in the waveguide system in terms of energy loss by using numerical simulation. Therefore, this study facilitates ultrasonic fingerprint impediography measurement based on the basic direct touch and quartz glass waveguide system.
引用
收藏
页码:402 / 411
页数:10
相关论文
共 25 条
  • [21] Single-Shot Near-Field Volumetric Imaging System for Optical Ultrasound and Photoacoustics Using Capacitive Micromachined Ultrasonic Transducer Without Transmission Mode
    Choi, Won Young
    Kwon, Soo Won
    Kim, Young Hun
    Kang, Ki Chang
    Park, Kwan Kyu
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (06) : 1151 - 1158
  • [22] Real-time 3D plane-wave imaging using annular capacitive micromachined ultrasonic transducer array
    Kwon, Young Seok
    Kim, Hae Youn
    Kang, Dong-Hyun
    Kim, Dong Hun
    Jeong, Jae-Woong
    Lee, Byung Chul
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 359
  • [23] A High-Frequency and High-Frame-Rate Ultrasound Imaging System Design on an FPGA Evaluation Board for Capacitive Micromachined Ultrasonic Transducer Arrays
    Wu, Xun
    Sanders, Jean
    Zhang, Xiao
    Yamaner, F. Yalcin
    Oralkan, Omer
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [24] A Low-Power Wearable E-Nose System Based on a Capacitive Micromachined Ultrasonic Transducer (CMUT) Array for Indoor VOC Monitoring
    Mahmud, Marzana Mantasha
    Seok, Chunkyun
    Wu, Xun
    Sennik, Erdem
    Biliroglu, Ali Onder
    Adelegan, Oluwafemi Joel
    Kim, Inhwan
    Jur, Jesse S.
    Yamaner, Feysel Yalcin
    Oralkan, Omer
    IEEE SENSORS JOURNAL, 2021, 21 (18) : 19684 - 19696
  • [25] Single-Shot Waterless Low-Profile Photoacoustic System: Near-Field Volumetric Imaging In Vivo for Blood Vessels Based on Capacitive Micromachined Ultrasonic Transducer (CMUT)
    Choi, Won Young
    Kim, Young Hun
    Jo, Hyeong Geun
    Pyun, Joo Young
    Kwon, Soo Won
    Park, Kwan Kyu
    SENSORS, 2019, 19 (05)