Extension of the ML-EM algorithm for dose estimation using PET in proton therapy: application to an inhomogeneous target

被引:5
|
作者
Masuda, Takamitsu [1 ]
Nishio, Teiji [1 ]
Sano, Akira [1 ,2 ]
Karasawa, Kumiko [3 ]
机构
[1] Tokyo Womens Med Univ, Grad Sch Med, Dept Med Phys, Shinjuku Ku, 8-1 Kawadacho, Tokyo 1628666, Japan
[2] Mizuho Informat & Res Inst Inc, Chiyoda Ku, 2-3 Kanda Nishikicho, Tokyo 1018443, Japan
[3] Tokyo Womens Med Univ, Sch Med, Dept Radiat Oncol, Shinjuku Ku, 8-1 Kawadacho, Tokyo 1628666, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 18期
关键词
proton therapy; PET imaging; dose estimation; range verification; filtering; ML-EM algorithm; POSITRON-EMISSION-TOMOGRAPHY; IN-BEAM; IMAGE-RECONSTRUCTION; RING OPENPET; VERIFICATION; DELIVERY; WASHOUT; BODY;
D O I
10.1088/1361-6560/ab98cf
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Positron emission tomography (PET) has been used forin vivotreatment verification, mainly for range verification, in proton therapy. Evaluating the direct dose from PET measurements remains challenging; however, it is highly desirable from a clinical perspective. In this study, a method for estimating the dose distribution from the positron emitter distributions was developed using the maximum likelihood expectation maximization algorithm. The 1D spatial relationship between positron emitter distributions and a dose distribution in an inhomogeneous target was inputted into the system matrix based on a filter framework. In contrast, spatial resolution of the PET system and total variation regularization (as prior knowledge for dose distribution) were considered in the 3D image-space. The dose estimation was demonstrated using Monte Carlo simulated PET activity distributions with substantial noise in a head and neck phantom. This mimicked the single field irradiation of the spread-out Bragg peak beams at clinical dose levels. Besides the simple implementation of the algorithm, this strategy achieved a high-speed calculation (30 s for a 3D dose estimation) and accurate dose and range estimations (less than 10% and 2 mm errors at 1-sigma values, respectively). The proposed method could be key for using PET forin vivodose monitoring.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Estimation of gametic frequencies from F2 populations using the EM algorithm and its application in the analysis of crossover interference in rice
    Esch, E
    THEORETICAL AND APPLIED GENETICS, 2005, 111 (01) : 100 - 109
  • [42] Explicit estimation of out-of-field neutron and gamma dose equivalents during proton therapy using thermoluminescence-dosimeters
    Mukherjee, B.
    Lambert, J.
    Hentschel, R.
    Farr, J.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1952 - 1955
  • [43] Estimation of boron (10B) concentration in blood and target tumors after therapeutic dose administration of borono-phenylalanine (BPA) using FBPA PET in boron neutron capture therapy
    Isohashi, Kayako
    Naka, Sadahiro
    Kanai, Yasukazu
    Horitsugi, Genki
    Watabe, Tadashi
    Kato, Hiroki
    Tatsumi, Mitsuaki
    Shimosegawa, Eku
    Hatazawa, Jun
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [44] Validation and application of a fast Monte Carlo algorithm for assessing the clinical impact of approximations in analytical dose calculations for pencil beam scanning proton therapy
    Huang, Sheng
    Souris, Kevin
    Li, Siyang
    Kang, Minglei
    Montero, Ana Maria Barragan
    Janssens, Guillaume
    Lin, Alexander
    Garver, Elizabeth
    Ainsley, Christopher
    Taylor, Paige
    Xiao, Ying
    Lin, Liyong
    MEDICAL PHYSICS, 2018, 45 (12) : 5631 - 5642
  • [45] High Dose Definitive Proton Therapy with Integrated Boost to Hypoxic Subvolumes Determined by [18F]-Fluoromisonidazole (FMISO) PET/CT for Patients with Recurrent Chordomas Using Intensity Modulated Proton Therapy (IMPT)
    Yan, S.
    Broussard, G.
    De, K.
    Bernstein, Amorim
    Wang, Y.
    MEDICAL PHYSICS, 2016, 43 (06) : 3508 - 3509
  • [46] Target and organ dose estimation from intensity modulated head and neck radiation therapy using 3 deformable image registration algorithms
    Kumarasiri, Akila
    Liu, Chang
    Siddiqui, Farzan
    Zhong, Hualiang
    Chetty, Indrin J.
    Kim, Jinkoo
    PRACTICAL RADIATION ONCOLOGY, 2015, 5 (04) : E317 - E325
  • [47] Machine Learning Based Oxygen and Carbon Concentration Derivation Using Dual-Energy CT for PET-Based Dose Verification in Proton Therapy
    Liu, Y.
    Zhou, L.
    PENG, H.
    Jia, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E221 - E221
  • [48] Machine learning based oxygen and carbon concentration derivation using dual-energy CT for PET-based dose verification in proton therapy
    Liu, Yuxiang
    Zhou, Long
    Peng, Hao
    MEDICAL PHYSICS, 2022, 49 (05) : 3347 - 3360
  • [49] Study of the RBE depth dependence of protons using a damage diagnostic algorithm and its application in proton therapy based on Monte Carlo simulation
    Ganjeh, Z. Ahmadi
    Eslami-Kalantari, M.
    Loushab, M. Ebrahimi
    JOURNAL OF INSTRUMENTATION, 2021, 16 (12):
  • [50] Adaptive intensity modulated proton therapy using 4D robust planning: a proof-of-concept for the application of dose mimicking approach
    Kaushik, Suryakant
    Stuetzer, Kristin
    Oeden, Jakob
    Fredriksson, Albin
    Toma-Dasu, Iuliana
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (18):