Estimation of the systolic pulmonary arterial pressure using contrast-enhanced continuous-wave Doppler in patients with trivial tricuspid regurgitation

被引:14
|
作者
Tokushima, T [1 ]
Utsunomiya, T [1 ]
Yoshida, K [1 ]
Ogawa, T [1 ]
Kido, K [1 ]
Ohtsubo, Y [1 ]
Ryu, T [1 ]
Ogata, T [1 ]
Tsuji, S [1 ]
Matsuo, S [1 ]
机构
[1] Saga Med Sch, Dept Internal Med, Div Cardiol, Saga 8498501, Japan
来源
JAPANESE HEART JOURNAL | 1999年 / 40卷 / 03期
关键词
continuous-wave Doppler; contrast-enhancement; physiological tricuspid regurgitation; pulmonary arterial pressure;
D O I
10.1536/jhj.40.311
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Noninvasive estimation of pulmonary arterial pressure is important for hemodynamic monitoring of patients with heart disease. In patients with tricuspid regurgitation (TR), the peak velocity of TR on continuous-wave (CW) Doppler can be used to estimate the systolic pulmonary arterial pressure (PAPs) using the simplified Bernoulli equation. We evaluated a new technique of contrast-enhanced CW Doppler for calculating PAPs in patients with trivial TR. Forty-one patients without visible TR detected by color Doppler, pulsed Doppler or CW Doppler were evaluated. Age ranged from 19 to 73 (55 +/- 12) years old. Tricuspid flow signals were recorded on CW Doppler after intravenous administration of indocyanin green (ICG) or Albunex. PAPs was calculated as; PAPs = 4 x V-TR(2) + 10 mmHg, where VTR is the peak velocity of TR. PAPs calculated using contrast-enhanced CW Doppler was compared with PAPs measured by the following cardiac catheterization. 1) TR signals were recorded using the contrast-enhanced CW Doppler technique in 39 of 41 patients (95%) after intravenous administration of contrast agents. 2) The error of estimate of PAPs using the contrast-enhanced CW Doppler technique was - 2.4 +/- 7.5 mmHg, and the percent error was -10.7 +/- 32.4% in all patients. In 20 of 39 patients (51%), the error of estimate was within + 5 mmHg. 3) PAPs was overestimated by 12.2 +/- 6.1 mmHg in patients with good contrast enhancement of TR signals. The contrast-enhanced CW Doppler technique is useful for estimating PAPs noninvasively in patients with trivial TR. It is better to assume the right atrial pressure as 3-5 mmHg, not 10 mmHg, in patients with good enhancement of trivial TR. Physiological TR may be enhanced by contrast agents in these patients.
引用
收藏
页码:311 / 320
页数:10
相关论文
共 50 条
  • [31] CONTINUOUS-WAVE DOPPLER ESTIMATION OF PRESSURE-GRADIENT IN PULMONARY STENOSIS - BEFORE AND AFTER PULMONARY VALVE BALLOON DILATATION
    GOSWAMI, KC
    SHRIVASTAVA, S
    DEV, V
    SAXENA, A
    BAHL, VK
    AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1992, 6 (04): : 237 - 241
  • [32] VALUE OF CONTINUOUS-WAVE DOPPLER IN THE ESTIMATION OF PULMONARY-ARTERY PRESSURE IN CHILDREN WITH SYSTEMIC TO PULMONARY-ARTERY SHUNTS
    QURESHI, SA
    DANGEL, JH
    BINI, RM
    ARNOLD, R
    WILKINSON, JL
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (714): : 633 - 633
  • [33] Estimation of pulmonary artery pressure by contrast-enhanced Doppler signals and comparison with catheter-measured pressures
    Akalin, N
    Tunaoglu, FS
    Olguntürk, R
    Kula, S
    TURKISH JOURNAL OF PEDIATRICS, 2001, 43 (04) : 317 - 322
  • [34] Continuous-wave Doppler echocardiographic evaluation of the changes in pulmonary arterial pressure during the first seven days of life
    Akiba, T
    Akiba, K
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (04): : 479 - +
  • [35] TRANSESOPHAGEAL CONTINUOUS-WAVE DOPPLER ESTIMATION OF LEFT ATRIAL PRESSURE WITH INTERATRIAL SHUNTING
    REDDY, SCB
    KATZ, WE
    REDDY, PS
    GORCSAN, J
    AMERICAN HEART JOURNAL, 1994, 127 (03) : 710 - 713
  • [36] Concepts and Tradeoffs in Velocity Estimation With Plane-Wave Contrast-Enhanced Doppler
    Tremblay-Darveau, Charles
    Williams, Ross
    Sheeran, Paul S.
    Milot, Laurent
    Bruce, Matthew
    Burns, Peter N.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (11) : 1890 - 1905
  • [37] USEFULNESS OF THE CONTINUOUS-WAVE DOPPLER-DERIVED PULMONARY ARTERIAL-RIGHT VENTRICULAR PRESSURE GRADIENT JUST BEFORE ATRIAL CONTRACTION FOR THE ESTIMATION OF PULMONARY ARTERIAL DIASTOLIC AND WEDGE PRESSURES
    Murayama, Michito
    Mikami, Taisei
    Kaga, Sanae
    Okada, Kazunori
    Hioka, Takuma
    Masauzi, Nobuo
    Nakabachi, Masahiro
    Nishino, Hisao
    Yokoyama, Shinobu
    Nishida, Mutsumi
    Iwano, Hiroyuki
    Sakakibara, Mamoru
    Yamada, Satoshi
    Tsutsui, Hiroyuki
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (05): : 958 - 966
  • [38] Potential Involvement of Functional Tricuspid Regurgitation in the Diagnostic Error to Assess Pulmonary Arterial Pressure by Doppler Echocardiography
    Yamamoto, Saori
    Matsumoto, Yasuharu
    Fukumoto, Yoshihiro
    Nochioka, Kotaro
    Miura, Masanobu
    Tetebe, Shunsuke
    Sugimura, Koichiro
    Suzuki, Tomoyuki
    Shimokawa, Hiroaki
    JOURNAL OF CARDIAC FAILURE, 2013, 19 (10) : S174 - S174
  • [39] Potential involvement of functional tricuspid regurgitation in the diagnostic error to assess pulmonary arterial pressure by doppler echocardiography
    Yamamoto, S.
    Matsumoto, Y.
    Nochioka, K.
    Miura, M.
    Tatebe, S.
    Sugimura, K.
    Suzuki, T.
    Fukumoto, Y.
    Shimokawa, H.
    EUROPEAN HEART JOURNAL, 2013, 34 : 37 - 37
  • [40] Reliability of echocardiographic estimation of pulmonary artery pressure in patients with severe tricuspid regurgitation
    Lemarchand, L.
    Leurent, G. L.
    Auffret, V. A.
    Donal, E. D.
    EUROPEAN HEART JOURNAL, 2022, 43 : 1557 - 1557