An electron beam linear scanning mode for industrial limited-angle nano-computed tomography

被引:6
|
作者
Wang, Chengxiang [1 ,2 ]
Zeng, Li [1 ,3 ]
Yu, Wei [4 ]
Zhang, Lingli [1 ,3 ]
Guo, Yumeng [1 ,3 ]
Gong, Changcheng [1 ]
机构
[1] Chongqing Univ, Educ Minist China, Engn Res Ctr Ind Computed Tomog Nondestruct Testi, Chongqing 400044, Peoples R China
[2] Univ Elect Sci & Technol China, Sch Math Sci, Chengdu 611731, Sichuan, Peoples R China
[3] Chongqing Univ, Coll Math & Stat, Chongqing 401331, Peoples R China
[4] Hubei Univ Sci & Technol, Sch Biomed Engn, Xianning 437100, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2018年 / 89卷 / 01期
基金
中国国家自然科学基金;
关键词
X-RAY NANOTOMOGRAPHY; MICRO-CT; IMAGE-RECONSTRUCTION; ALGORITHM; MINIMIZATION; DESIGN; SYSTEM;
D O I
10.1063/1.4993933
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Nano-computed tomography (nano-CT), which utilizes X-rays to research the inner structure of some small objects and has been widely utilized in biomedical research, electronic technology, geology, material sciences, etc., is a high spatial resolution and non-destructive research technique. A traditional nano-CT scanning model with a very high mechanical precision and stability of object manipulator, which is difficult to reach when the scanned object is continuously rotated, is required for high resolution imaging. To reduce the scanning time and attain a stable and high resolution imaging in industrial non-destructive testing, we study an electron beam linear scanning mode of nano-CT system that can avoid mechanical vibration and object movement caused by the continuously rotated object. Furthermore, to further save the scanning time and study how small the scanning range could be considered with acceptable spatial resolution, an alternating iterative algorithm based on l(0) minimization is utilized to limited-angle nano-CT reconstruction problem with the electron beam linear scanning mode. The experimental results confirm the feasibility of the electron beam linear scanning mode of nano-CT system. Published by AIP Publishing.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Artifact removal using a hybrid-domain convolutional neural network for limited-angle computed tomography imaging
    Zhang, Qiyang
    Hu, Zhanli
    Jiang, Changhui
    Zheng, Hairong
    Ge, Yongshuai
    Liang, Dong
    Ge, Yongshuai (ys.ge@siat.ac.cn); Liang, Dong (dong.liang@siat.ac.cn), 1600, IOP Publishing Ltd (65):
  • [42] Artifact removal using a hybrid-domain convolutional neural network for limited-angle computed tomography imaging
    Zhang, Qiyang
    Hu, Zhanli
    Jiang, Changhui
    Zheng, Hairong
    Ge, Yongshuai
    Liang, Dong
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (15):
  • [43] Cone-beam Computed Tomographic-based Assessment of Filled C-shaped Canals: Artifact Expression of Cone-beam Computed Tomography as Opposed to Micro-computed Tomography and Nano-computed Tomography
    Mazzi-Chaves, Jardel Francisco
    Vasconcelos, Karla de Faria
    Pauwels, Ruben
    Jacobs, Reinhilde
    Sousa-Neto, Manoel Damiao
    JOURNAL OF ENDODONTICS, 2020, 46 (11) : 1702 - 1711
  • [44] Iterative image reconstruction using modified non-local means filtering for limited-angle computed tomography
    Qi, Hongliang
    Chen, Zijia
    Wu, Shuyu
    Xu, Yuan
    Zhou, Linghong
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (09): : 1041 - 1051
  • [45] Industrial computed tomography and its application based on cone-beam scanning
    Min, Y
    Sun, CL
    Zhang, QH
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 5758 - 5761
  • [46] Atlas-assisted tomography: Registration of a deformable atlas to compensate for limited-angle cone-beam trajectory
    Sadowsky, Ofri
    Ramamurthi, Krishnakumar
    Ellingsen, Lotta M.
    Chintalapani, Gouthami
    Prince, Jerry L.
    Taylor, Russell H.
    2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 1244 - +
  • [47] IMAGE-RECONSTRUCTION BY ANGLE-LIMITED DATA IN INDUSTRIAL COMPUTED-TOMOGRAPHY
    KLYUEV, VV
    MAKLASHEVSKY, VY
    TIMONOV, AA
    FILINOV, VN
    DOKLADY AKADEMII NAUK, 1993, 331 (02) : 155 - 157
  • [48] Limited-Angle Computed Tomography Reconstruction using Combined FDK-Based Neural Network and U-Net
    Wang, Yiying
    Yang, Tao
    Huang, Weimin
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 1572 - 1575
  • [49] Non-cardiac findings on coronary electron beam computed tomography scanning
    Schragin, JG
    Weissfeld, JL
    Edmundowicz, D
    Strollo, DC
    Fuhrman, CR
    JOURNAL OF THORACIC IMAGING, 2004, 19 (02) : 82 - 86
  • [50] Improved scanning and reconstruction of large objects by cone-beam industrial computed, tomography
    Zeng, Li
    Zou, Xiaobing
    Wang, Jue
    Wang, Ping
    Hunziker, Patrick R.
    PROCEEDINGS OF THE NINTH IASTED INTERNATIONAL CONFERENCE ON SIGNAL AND IMAGE PROCESSING, 2007, : 46 - +