EFFECTS OF NON-CONDENSABLE GAS ON CHARACTERISTICS OF NATURAL CIRCULATION FLOW OF ISOLATION CONDENSER

被引:0
|
作者
Takada, Tetsuya [1 ]
Yamamoto, Yasunori [1 ]
Ono, Kosuke [1 ]
机构
[1] Hokkaido Univ, Sapporo, Hokkaido, Japan
关键词
Isolation condenser; Non-condensable gas; Natural circulation flow; High pressure steam; Condensation heat transfer;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An isolation condenser (IC) is a passive core cooling system in boiling water reactors. The cooling performance of IC is deteriorated when hydrogen generated in the core flows into the IC pipes. In this study, we conducted high pressure experiments using natural circulation loop with non-condensable gas injection, where helium was used to simulate hydrogen effect on the IC. The reaching distance of steam in the heat transfer tube was estimated by observing the region where nucleate boiling occurred on the outer surface of the heat transfer tube, and the heat transfer coefficient was estimated. The heat transfer coefficient hardly changed when helium was injected to the loop that indicates injected helium was not accumulated in the heat transfer tube. The system pressure at quasi-steady state increased with increasing amount of the injected helium. Since the differential pressure at the down comer section increased by helium injection, the injected helium may be accumulated in the section, leading to increment of the system pressure.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] A condensation heat transfer model with light gas effects in non-condensable gas mixtures
    Hwang, Ji-Hwan
    Jerng, Dong-Wook
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2022, 130
  • [22] CONDENSATION HEAT TRANSFER IN PRESENCE OF A NON-CONDENSABLE GAS
    KROGER, DG
    ROHSENOW, WM
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1968, 11 (01) : 15 - &
  • [23] The effects of non-condensable gases in domestic appliances
    Cecchinato, Luca
    Dell'Eva, Maurizio
    Fornasieri, Ezio
    Marcer, Massimo
    Monego, Orlando
    Zilio, Claudio
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (01): : 19 - 27
  • [24] INFLUENCES OF NON-CONDENSABLE GAS ON STEAM BUBBLE CONDENSATION
    DIMIC, M
    CHEMISCHE TECHNIK, 1982, 34 (03): : 163 - 163
  • [25] Effect of non-condensable gas on heat transfer within the hollow fin condenser of metallic and polymer vapor chambers
    Berut, Elise
    Lips, Stephane
    Lefevre, Frederic
    Sartre, Valerie
    APPLIED THERMAL ENGINEERING, 2021, 190
  • [26] REFLUX CONDENSER MODE WITH NON-CONDENSABLE GAS - ASSESSMENT OF CATHARE AGAINST BETHSY TEST-7.2C
    NOEL, B
    DERUAZ, R
    NUCLEAR ENGINEERING AND DESIGN, 1994, 149 (1-3) : 291 - 298
  • [27] Condensation of vapours on a fin in the presence of non-condensable gas
    Sarma, PK
    Reddy, MA
    Bergles, AE
    Kakac, S
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (17) : 3233 - 3240
  • [28] HOMOGENEOUS NUCLEATION IN A MIXTURE OF VAPOR AND NON-CONDENSABLE GAS
    POINSOT, T
    HUETZ, J
    REVUE DE PHYSIQUE APPLIQUEE, 1985, 20 (03): : 163 - 172
  • [29] Effects of non-condensable gas on thermodynamic performance of transcritical organic Rankine cycle
    Wang, Shukun
    Li, Ke
    Yu, Wei
    Liu, Chao
    Guan, Zhengjun
    ENERGY, 2024, 292
  • [30] EFFECTS OF NON-CONDENSABLE GAS ON LAMINAR-FILM CONDENSATION IN A VERTICAL TUBE
    WANG, CY
    TU, CJ
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1988, 31 (11) : 2339 - 2345