COMPARISON OF TWO BIOELECTRICAL IMPEDANCE ANALYSIS DEVICES WITH DUAL ENERGY X-RAY ABSORPTIOMETRY AND MAGNETIC RESONANCE IMAGING IN THE ESTIMATION OF BODY COMPOSITION

被引:90
|
作者
Wang, Ji-Guang [1 ]
Zhang, Yi [1 ]
Chen, Han-E [1 ]
Li, Yan [1 ]
Cheng, Xiao-Guang [2 ]
Xu, Li [2 ]
Guo, Zhe [2 ]
Zhao, Xing-Shan [3 ]
Sato, Tetsuya [4 ]
Cao, Qi-Yun [5 ]
Chen, Ke-Min [6 ]
Li, Biao [7 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Ctr Epidemiol Studies & Clin Trials, Shanghai Inst Hypertens,Ruijin Hosp, Shanghai 200030, Peoples R China
[2] Beijing Univ, Jishuitan Hosp, Dept Radiol, Beijing 100871, Peoples R China
[3] Beijing Univ, Jishuitan Hosp, Dept Cardiol, Beijing 100871, Peoples R China
[4] Omron Healthcare, Kyoto, Japan
[5] Omron Healthcare, Shanghai, Peoples R China
[6] Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Dept Radiol, Shanghai 200030, Peoples R China
[7] Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Dept Nucl Med, Shanghai 200030, Peoples R China
关键词
fat; skeletal muscle; visceral fat; measurement; accuracy; SKELETAL-MUSCLE MASS; VALIDATION; APPLICABILITY; PREVALENCE; PREDICTION; OVERWEIGHT; EQUATION;
D O I
10.1519/JSC.0b013e31824f2040
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Wang, J-G, Zhang, Y, Chen, H-E, Li, Y, Cheng, X-G, Xu, L, Guo, Z, Zhao, X-S, Sato, T, Cao, Q-Y, Chen, K-M, and Li, B. Comparison of two bioelectrical impedance analysis devices with dual energy X-ray absorptiometry and magnetic resonance imaging in the estimation of body composition. J Strength Cond Res 27(1): 236-243, 2013-We compared a 4-limb bioelectrical impedance analysis (BIA) system, HBF 359 (Omron), and a 2-limb foot-to-foot device, BC 532 (Tanita), with the standard dual energy X-ray absorptiometry (DXA) and magnetic resonance imaging (MRI) methods for the measurement of body fat percentage (BF), skeletal muscle mass percentage (SMM, or fat-free mass [FFM] for BC 532), and visceral fat level (VF). Body composition was measured in 200 healthy volunteers (100 men and 100 women, mean age 48 years) by HBF 359 and BC 532 and by DXA and MRI. The agreement was assessed by correlation analysis and paired t-test. The correlation coefficients between BIA and DXA or MRI ranged from 0.71 to 0.89 for BF, SMM, and VF by HBF 359 and from 0.77 to 0.90 for BF, FFM, and VF by BC 532 in all subjects and in men and women separately (p < 0.001 for all). Compared with DXA, HBF 359 significantly (p < 0.001) underestimated BF by -5.8% in men and -9.6% in women. Compared with MRI, the corresponding underestimatons (negative) or overestimations (positive) by HBF 359 in men and women were, respectively, +1.9% (p = 0.02) and +1.7% (p = 0.10) for SMM, and +13.3% (p < 0.001) and -8.5% (p = 0.006), for VF. The corresponding values by BC 532 in men and women were -10.7 and -6.2% for BF, -1.4 and -2.5% for FFM, and +20.4 and -18.0% for VF. The BIA devices are accurate in the estimation of body composition, especially skeletal muscle mass or FFM.
引用
收藏
页码:236 / 243
页数:8