Evaluation of real-time acoustical holography for breast imaging and biopsy guidance

被引:3
|
作者
Lehman, CD [1 ]
André, MP [1 ]
Fecht, BA [1 ]
Johansen, JM [1 ]
Shelby, RL [1 ]
Shelby, JO [1 ]
机构
[1] Univ Washington, Med Ctr, Seattle, WA 98195 USA
关键词
ultrasound; transmission; holography; real-time; mammography; breast cancer; sonography; CCD;
D O I
10.1117/12.349498
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ultrasound is an attractive modality for adjunctive characterization of certain breast lesions, but it is not considered specific for cancer and it is not recommended for screening. An imaging technique remarkably different from pulse-echo ultrasound, termed Optical Sanography(TM) (Advanced Diagnostics, Inc.), uses the through-transmission signal. The method was-applied to breast examinations in 41 asymptomatic and symptomatic women ranging in age from 18 to 83 years to evaluate this imaging modality for detection and characterization of breast disease and normal tissue. This approach uses coherent sound and coherent light to produce real-time, large field-of-view images with pronounced edge definition in soft tissues of the body. The System patient interface was modified to improve coupling to the breast and bring the chest wall to within 3 cm of the sound beam; System resolution (full width half maximum of the line-spread function) was 0.5 mm for a swept-frequency beam centered at 2.7 MHz. Resolution degrades slightly in the periphery of the very large 15.2-cm field of view. Dynamic range of the reconstructed "raw" images (no post processing) was 3000:1. Included in the study population were women with dense parenchyma, palpable ductal carcinoma in situ with negative mammography, superficial and deep fibroadenomas, and calcifications. Successful breast imaging was performed in 40 of 41 women. These images were then compared with images generated using conventional X-ray mammography and pulse-echo ultrasound. Margins of lesions and internal-textures were particularly well defined and provided substantial contrast to fatty and dense parenchyma In two malignant lesions, Optical Sonography(TM) appeared to approximate more closely tumor extent compared to mammography than pulse-echo sonography; These preliminary studies indicate the method has unique potential for detecting, differentiating, and guiding the biopsy of breast lesions using real-time acoustical holography.
引用
收藏
页码:236 / 243
页数:8
相关论文
共 50 条
  • [41] A novel system for real-time planning and guidance of breast HDR brachytherapy
    Poulin, E.
    Gardi, L.
    Barker, K.
    Montreuil, J.
    Pouliot, J.
    Fenster, A.
    Beaulieu, L.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 467 - 470
  • [42] Automatic real-time guidance of laser machining with inline coherent imaging
    Webster, Paul J. L.
    Wright, Logan G.
    Mortimer, Kevin D.
    Leung, Ben Y.
    Yu, Joe X. Z.
    Fraser, James M.
    JOURNAL OF LASER APPLICATIONS, 2011, 23 (02)
  • [43] Interventional real-time optical imaging guidance for complete tumor ablation
    Kan, Xuefeng
    Zhang, Feng
    Zhou, Guanhui
    Ji, Hongxiu
    Monsky, Wayne
    Ingraham, Christopher
    Zheng, Chuansheng
    Yang, Xiaoming
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2021, 118 (41)
  • [44] BREAST LIGHT SCANNING - A REAL-TIME BREAST-IMAGING MODALITY
    MCINTOSH, DMF
    JOURNAL OF THE CANADIAN ASSOCIATION OF RADIOLOGISTS-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1983, 34 (04): : 288 - 290
  • [45] Robot-Assisted Real-Time Tumor Manipulation for Breast Biopsy
    Mallapragada, Vishnu G.
    Sarkar, Nilanjan
    Podder, Tarun K.
    IEEE TRANSACTIONS ON ROBOTICS, 2009, 25 (02) : 316 - 324
  • [46] Percutaneous Punctures with MR Imaging Guidance: Comparison between MR Imaging-enhanced Fluoroscopic Guidance and Real-time MR Imaging Guidance
    Meyer, Bernhard Christian
    Brost, Alexander
    Kraitchman, Dara L.
    Gilson, Wesley D.
    Strobel, Norbert
    Hornegger, Joachim
    Lewin, Jonathan S.
    Wacker, Frank K.
    RADIOLOGY, 2013, 266 (03) : 912 - 919
  • [47] Ultrawideband Underwater Real-Time 3-D Acoustical Imaging With Ultrasparse Arrays
    Chi, Cheng
    Li, Zhaohui
    Li, Qihu
    IEEE JOURNAL OF OCEANIC ENGINEERING, 2017, 42 (01) : 97 - 108
  • [48] Use of real-time magnetic resonance guidance to assist bone biopsy in pediatric malignancy
    Ueno, S
    Yokoyama, S
    Hirakawa, H
    Yabe, H
    Suzuki, Y
    Atsumi, H
    Matsumae, M
    PEDIATRICS, 2002, 109 (01) : E18
  • [49] Transbronchial Biopsy for Peripheral Pulmonary Lesions Under Real-time Endobronchial Ultrasonographic Guidance
    Shinagawa, Naofumi
    Yamada, Noriyuki
    Asahina, Hajime
    Kikuchi, Eiki
    Oizumi, Satoshi
    Kurimoto, Noriaki
    Nishimura, Masaharu
    JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2009, 16 (04) : 261 - 265
  • [50] New photorefractive polymers for real-time holography
    Schloter, S
    Hofmann, U
    Hagen, R
    Hohle, C
    Ewert, K
    Strohriegl, P
    Eisenbach, CD
    Schmidt, HW
    Haarer, D
    XEROGRAPHIC PHOTORECEPTORS AND ORGANICS PHOTOREFRACTIVE MATERIALS II, 1997, 3144 : 142 - 153