Dynamic response of a shear stress transducer in the sliding plate rheometer

被引:7
|
作者
Kolitawong, C
Giacomin, AJ
机构
[1] Univ Wisconsin, Dept Mech Engn, Madison, WI 53706 USA
[2] Univ Wisconsin, Rheol Res Ctr, Madison, WI 53706 USA
[3] Natl Univ Singapore, Dept Chem & Environm Engn, Singapore 119260, Singapore
关键词
sliding plate rheometer; transducer damping; shear stress transducer; bipolar cylindrical coordinates; dynamic transducer calibration;
D O I
10.1016/S0377-0257(01)00139-2
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The damping caused by polymer melt, which commonly gets into the housing of a shear stress transducer, is determined analytically. The analysis employs bipolar coordinates and is applied to Newtonian and then linear viscoelastic fluids, Results are compared with available dynamic calibration measurements, and also with previously used semi-empirical models for the transducer damping. Dimensionless graphs are then provided for estimating transducer attenuation and phase error in oscillatory shear measurements. Examples are given showing how to use the results for rheometer design and to assess measurement accuracy. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:71 / 96
页数:26
相关论文
共 50 条
  • [41] Shear stress transducer. Rheological applications
    Dealy, J.M.
    Proceedings of the International Congress on Rheology, 1992,
  • [42] A shear rheometer for measuring shear stress and both normal stress differences in polymer melts simultaneously: the MTR 25
    Thomas Schweizer
    Jürg Hostettler
    Fredy Mettler
    Rheologica Acta, 2008, 47 : 943 - 957
  • [43] A micro-extraction method for use with 4 mm plate geometry in the Dynamic Shear Rheometer to evaluate asphalt binder rheology
    Filonzi, Angelo
    Lee, Sang Ki
    Ferreira, Wellington
    Hajj, Ramez
    Bhasin, Amit
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 252 (252)
  • [44] A shear rheometer for measuring shear stress and both normal stress differences in polymer melts simultaneously: the MTR 25
    Schweizer, Thomas
    Hostettler, Juerg
    Mettler, Fredy
    RHEOLOGICA ACTA, 2008, 47 (08) : 943 - 957
  • [45] Steady flow and dynamic viscoelastic behavior of nylon 1313 using parallel-plate rheometer and capillary rheometer
    Wang, YD
    Zhao, QX
    Liu, MY
    Wang, ZM
    Liu, YK
    Cao, SK
    Zha, TZ
    JOURNAL OF APPLIED POLYMER SCIENCE, 2005, 98 (04) : 1643 - 1651
  • [46] Understanding mechanisms leading to asphalt binder fatigue in the dynamic shear rheometer
    Hintz, Cassie
    Bahia, Hussain
    ROAD MATERIALS AND PAVEMENT DESIGN, 2013, 14 : 231 - 251
  • [47] Study of Asphalt Binder Fatigue with a New Dynamic Shear Rheometer Geometry
    Apostolidis, Panos
    Kasbergen, Cor
    Bhasin, Amit
    Scarpas, Athanassios
    Erkens, Sandra
    TRANSPORTATION RESEARCH RECORD, 2018, 2672 (28) : 290 - 300
  • [48] Fatigue testing and evaluation of asphalt binders using the dynamic shear rheometer
    Shenoy, A
    JOURNAL OF TESTING AND EVALUATION, 2002, 30 (04) : 303 - 312
  • [49] Accelerated Dynamic Shear Rheometer Fatigue Test for investigating asphalt mastic
    Kim, Yun Su
    Sigwarth, Tess
    Buechner, Johannes
    Wistuba, Michael P.
    ROAD MATERIALS AND PAVEMENT DESIGN, 2021, 22 (S1) : S383 - S396
  • [50] Studying asphalt binder fatigue pattern by using a dynamic shear rheometer
    Reyes Ortiz, Oscar Javier
    Perez Jimenez, Felix E.
    INGENIERIA E INVESTIGACION, 2011, 31 (01): : 47 - 55