Reliability of real-time ultrasound for measuring skeletal muscle size in human limbs in vivo: a systematic review

被引:67
|
作者
English, Coralie [1 ]
Fisher, Laura [2 ]
Thoirs, Kerry [1 ]
机构
[1] Univ S Australia, Sch Hlth Sci, Int Ctr Allied Hlth Evidence, Adelaide, SA 5001, Australia
[2] Univ S Australia, Adelaide, SA 5001, Australia
关键词
Real-time B-mode ultrasound; skeletal muscle; human limbs; CROSS-SECTIONAL AREA; B-MODE ULTRASOUND; THICKNESS MEASUREMENTS; SUBCUTANEOUS FAT; JAPANESE ADULTS; REHABILITATION; PREDICTION; ARCHITECTURE; VALIDATION; CHILDREN;
D O I
10.1177/0269215511434994
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To systematically review evidence for the reliability of real-time brightness-mode ultrasound for assessing skeletal muscle size in human limbs in vivo and to establish in which populations and anatomical sites the reliability had been tested. Data sources: Articles were retrieved via electronic database searching and expert contact. Study selection: Studies reporting reliability indices of test-retest measures of real-time brightness-mode ultrasound measures of skeletal muscle size within human limbs were included. Data extraction: Articles were assessed for methodological quality by two reviewers, decisions were made by consensus. Participant characteristics, measurement protocol, ultrasound protocol, type of reliability measured and statistical methods were extracted by one reviewer. Data synthesis: Twenty-four articles were included, involving 605 participants. Studies were of low to moderate methodological quality. Most studies were conducted within the healthy population. Only one study demonstrated poor reliability at one site only, and only when the participants were measured in the supine position. Conclusion: There is a moderate amount of low-level evidence that real-time brightness-mode ultrasound has good reliability for measuring muscle size across a number of limb sites in healthy populations. There is limited evidence for the reliability of ultrasound measures of muscle size in clinical populations.
引用
收藏
页码:934 / 944
页数:11
相关论文
共 50 条
  • [21] Real-Time Medical Systems Based on Human Biometric Steganography: a Systematic Review
    A. H. Mohsin
    A. A. Zaidan
    B. B. Zaidan
    Shamsul Arrieya bin Ariffin
    O. S. Albahri
    A. S. Albahri
    M. A. Alsalem
    K. I. Mohammed
    M. Hashim
    Journal of Medical Systems, 2018, 42
  • [22] Ultrasound-array-based real-time photoacoustic microscopy of human pulsatile dynamics in vivo
    Song, Liang
    Maslov, Konstantin
    Shung, K. Kirk
    Wang, Lihong V.
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (02)
  • [23] Real-time contrast-enhanced ultrasound (RT-CEU) for the determination of flowmotion within skeletal muscle
    Rattigan, Stephen
    Bradley, Eloise M.
    Richards, Stephen M.
    Keske, Michelle A.
    FASEB JOURNAL, 2012, 26
  • [24] A SYSTEMATIC METHOD FOR EXAMINATION OF THE NEONATAL BRAIN BY REAL-TIME ULTRASOUND
    LEVENE, MI
    DUBOWITZ, V
    WIGGLESWORTH, JS
    ARCHIVES OF DISEASE IN CHILDHOOD, 1980, 55 (09) : 733 - 733
  • [25] Associations of Real-Time Ultrasound and Strain and Shear Wave Elastography with Gastrointestinal Organs: A Systematic Review
    Javed, Nismat
    Ghazanfar, Haider
    Jyala, Abhilasha
    Patel, Harish
    DIAGNOSTICS, 2023, 13 (21)
  • [26] Real-time Photoacoustic & Ultrasound imaging of human vasculature
    Kolkman, Roy G. M.
    Brands, Peter J.
    Steenbergen, Wiendelt
    van Leeuwen, Ton G.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2009, 2009, 7177
  • [27] Real-time in vivo detection techniques for neurotransmitters: a review
    Su, Yi
    Bian, Sumin
    Sawan, Mohamad
    ANALYST, 2020, 145 (19) : 6193 - 6210
  • [28] cGMP increases induced by NO-donors measured in real-time using FRET in skeletal muscle arterioles in vivo
    Thiele, L.
    Schmidt, K.
    de Wit, C.
    ACTA PHYSIOLOGICA, 2022, 236 : 173 - 173
  • [29] A MICROCOMPUTER MEASURING SYSTEM APPLIED TO REAL-TIME ULTRASOUND VIDEO IMAGING
    GODFREY, KA
    FLANAGAN, GJ
    GERRARD, J
    LIND, T
    JOURNAL OF CLINICAL ULTRASOUND, 1981, 9 (06) : 309 - 313
  • [30] Specific tension of human muscle in vivo: a systematic review
    Persad, Lomas S.
    Wang, Zheng
    Pino, Paula A.
    Binder-Markey, Benjamin I.
    Kaufman, Kenton R.
    Lieber, Richard L.
    JOURNAL OF APPLIED PHYSIOLOGY, 2024, 137 (04) : 945 - 962