Field evaluation of a random forest activity classifier for wrist-worn accelerometer data

被引:118
|
作者
Payey, Toby G. [1 ,2 ]
Gilson, Nicholas D. [2 ]
Gomersall, Sjaan R. [2 ]
Clark, Bronwyn [3 ]
Trost, Stewart G. [1 ]
机构
[1] Queensland Univ Technol, Sch Exercise & Nutr Sci, Brisbane, Qld, Australia
[2] Univ Queensland, Sch Human Movement & Nutr Sci, Brisbane, Qld, Australia
[3] Univ Queensland, Sch Publ Hlth, Brisbane, Qld, Australia
关键词
Accelerometer; Random forest classifier; Physical activity; Wrist; ENERGY-EXPENDITURE; PHYSICAL-ACTIVITY; SEDENTARY BEHAVIOR; HIP; PREDICTION;
D O I
10.1016/j.jsams.2016.06.003
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Objectives: Wrist-worn accelerometers are convenient to wear and associated with greater wear-time compliance. Previous work has generally relied on choreographed activity trials to train and test classification models. However, validity in free-living contexts is starting to emerge. Study aims were: (1) train and test a random forest activity classifier for wrist accelerometer data; and (2) determine if models trained on laboratory data perform well under free-living conditions. Design: Twenty-one participants (mean age = 27.6 +/- 6.2) completed seven lab-based activity trials and a 24 h free-living trial (N = 16). Methods: Participants wore a GENEActiv monitor on the non-dominant wrist. Classification models recognising four activity classes (sedentary, stationary+, walking, and running) were trained using time and frequency domain features extracted from 10-s non-overlapping windows. Model performance was evaluated using leave-one-out-cross-validation. Models were implemented using the randomForest package within R. Classifier accuracy during the 24 h free living trial was evaluated by calculating agreement with concurrently worn activPAL monitors. Results: Overall classification accuracy for the random forest algorithm was 92.7%. Recognition accuracy for sedentary, stationary+, walking, and running was 80.1%, 95.7%, 91.7%, and 93.7%, respectively for the laboratory protocol. Agreement with the activPAL data (stepping vs. non-stepping) during the 24 h free-living trial was excellent and, on average, exceeded 90%. The ICC for stepping time was 0.92 (95% Cl = 0.75-0.97). However, sensitivity and positive predictive values were modest. Mean bias was 10.3 min/d (95% LOA = 46.0 to 25.4 min/d). Conclusions: The random forest classifier for wrist accelerometer data yielded accurate group-level predictions under controlled conditions, but was less accurate at identifying stepping verse non-stepping behaviour in free living conditions Future studies should conduct more rigorous field-based evaluations using observation as a criterion measure. (C) 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:75 / 80
页数:6
相关论文
共 50 条
  • [31] Step-length Estimation using Wrist-worn Accelerometer and GPS
    Kao, Wei-Wen
    Chen, Ching-Kun
    Lin, Jing-Shian
    PROCEEDINGS OF THE 24TH INTERNATIONAL TECHNICAL MEETING OF THE SATELLITE DIVISION OF THE INSTITUTE OF NAVIGATION (ION GNSS 2011), 2011, : 3274 - 3280
  • [32] A Novel Method Of Assessing Dietary Behavior Using a Wrist-Worn Accelerometer
    Winfree, Kyle N.
    Dmitrieva, Natalia O.
    Behrens, Timothy K.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 14 - 14
  • [33] Activity Recognition Using Wrist-Worn Sensors for Human Performance Evaluation
    Minh Nguyen
    Fan, Liyue
    Shahabi, Cyrus
    2015 IEEE INTERNATIONAL CONFERENCE ON DATA MINING WORKSHOP (ICDMW), 2015, : 164 - 169
  • [34] Levels of Activity Identification & Sleep Duration Detection with a Wrist-Worn Accelerometer-Based Device
    Verma, Vijay Kumar
    Lin, Wen-Yen
    Lee, Ming-Yih
    Lai, Chao-Sung
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 2369 - 2372
  • [35] Estimating Sedentary Time from a Hip- and Wrist-Worn Accelerometer
    Marcotte, Robert T.
    Petrucci, Greg J.
    Cox, Melanna F.
    Freedson, Patty S.
    Staudenmayer, John W.
    Sirard, John R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2020, 52 (01): : 225 - 232
  • [36] The Influence Of Wrist-worn Accelerometer Wear Location On Free-living Physical Activity In Adolescents
    Davila, Edward M.
    Heil, Daniel P.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 491 - 492
  • [37] uLift: Adaptive Workout Tracker Using a Single Wrist-Worn Accelerometer
    Lim, Jongkuk
    Oh, Youngmin
    Choi, Younggeun
    IEEE ACCESS, 2024, 12 : 21710 - 21722
  • [38] Wrist-worn Versus Thigh-worn Accelerometers: Compliance And Participant Perspectives On Accelerometer Placement
    Hidde, Mary C.
    Bandera, Victoria
    Lyden, Kate
    Braun, Barry
    Leach, Heather J.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2021, 53 (08): : 233 - 233
  • [39] Estimating Free-living Physical Activity Using A Wrist-worn Actigraph Accelerometer: Can It Be Done?
    Petrucci, Greg J., Jr.
    Marcotte, Robert T.
    Cox, Melanna F.
    Staudenmayer, John
    Freedson, Patty S.
    Sirard, John R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 164 - 165
  • [40] Physical Activity Recognition Using Streaming Data from Wrist-worn Sensors
    Kongsil, Katika
    Suksawatchon, Jakkarin
    Suksawatchon, Ureerat
    PROCEEDINGS OF THE 2019 4TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY (INCIT): ENCOMPASSING INTELLIGENT TECHNOLOGY AND INNOVATION TOWARDS THE NEW ERA OF HUMAN LIFE, 2019, : 274 - 279