Fast determination of tetrafluoroborate by high-performance liquid chromatography using a monolithic column

被引:33
|
作者
Zhou, Shuang [1 ]
Yu, Hong [1 ]
Yang, Ling [1 ]
Ai, Hongjing [1 ]
机构
[1] Harbin Normal Univ, Coll Chem & Chem Engn, Harbin 150025, Peoples R China
关键词
monolithic; high-performance liquid chromatography; tetrafluoroborate; conductivity detection; ionic liquids;
D O I
10.1016/j.chroma.2008.08.048
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fast determination of tetrafluoroborate by high-performance liquid chromatography using a silica-based monolithic column and direct conductivity detection was carried out. Chromatographic separation was performed on a Chromolith Speed ROD RP-18e column (50 mm x 4.6 mm i.d.) with tetrabutylammonium hydroxide (TBA-OH) + phthalic acid as eluent. The effects of eluent concentration, eluent pH, column temperature and flow rate on retention time of tetrafluoroborate were investigated. The optimized chromatographic conditions for determination of tetrafluoroborate were using 0.5 mM TBA-OH + 0.31 mM phthalic acid (pH 5.5) as eluent, column temperature of 30 degrees C and flow rate of 6.0 mL/min. Retention time of tetrafluoroborate was less than 1 min under the conditions. Common anions (Cl-, Br-, NO3- and SO42-) did not interfere with the determination of tetrafluoroborate. Detection limit (S/N = 2) for tetrafluoroborate was 1.4 mg/L. The linear range of calibration curve between peak area and the concentration of tetrafluoroborate was from 1.4 to 100.0 mg/L. The reproducibility was 0.09% and 1.8% (n = 5) relative standard deviation (RSD) for retention time and peak area, respectively. The method has been applied to the determination of tetrafluoroborate in ionic liquids. Recoveries of tetrafluoroborate after spiking were 98.2-101.5%. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:200 / 203
页数:4
相关论文
共 50 条
  • [41] DETERMINATION OF STERIGMATOCYSTIN IN FEED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN SWITCHING
    LEPOM, P
    JOURNAL OF CHROMATOGRAPHY, 1986, 354 : 518 - 523
  • [42] Determination of bisphenol A in beer by immunoaffinity column tandem high-performance liquid chromatography
    Li, K. H.
    Zhu, L. X.
    Liu, R. R.
    Meng, W.
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND MANAGEMENT INNOVATION, 2015, 28 : 230 - 234
  • [43] Determination of adenosine and deoxyadenosine in urine by high-performance liquid chromatography with column switching
    Yamamoto, T
    Moriwaki, Y
    Takahashi, S
    Fujita, T
    Tsutsumi, Z
    Yamakita, J
    Shimizu, K
    Shioda, M
    Ohta, S
    Higashino, K
    JOURNAL OF CHROMATOGRAPHY B, 1998, 719 (1-2): : 55 - 61
  • [44] Determination of Rosuvastatin and Ezetimibe in a Combined Tablet Dosage Form Using High-Performance Column Liquid Chromatography and High-Performance Thin-Layer Chromatography
    Varghese, Susheel John
    Ravi, Thengungal Kochupappy
    JOURNAL OF AOAC INTERNATIONAL, 2010, 93 (04) : 1222 - 1227
  • [45] DETERMINATION OF CICLETANINE IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING AUTOMATED COLUMN SWITCHING
    ANTONIEWICZ, SM
    COOK, JA
    BROWN, RR
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 573 (01): : 93 - 98
  • [46] Flow-through pore characteristics of monolithic silicas and their impact on column performance in high-performance liquid chromatography
    Skudas, R.
    Grimes, B. A.
    Thommes, M.
    Unger, K. K.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (13) : 2625 - 2636
  • [47] RAPID EXTRELUT COLUMN METHOD FOR DETERMINATION OF LEVAMISOLE IN MILK USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    OSTERDAHL, BG
    JOHNSSON, H
    NORDLANDER, I
    JOURNAL OF CHROMATOGRAPHY, 1985, 337 (01): : 151 - 155
  • [48] DETERMINATION OF LANSOPRAZOLE AND ITS METABOLITES IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING A LOOP COLUMN
    LANDES, BD
    MISCORIA, G
    FLOUVAT, B
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 577 (01): : 117 - 122
  • [49] Determination of oxytetracycline levels in rainbow trout serum on a biphenyl column using high-performance liquid chromatography
    Miller, Ron A.
    Reimschuessel, Renate
    Carson, Mary C.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 655 - 658
  • [50] DETERMINATION OF PSILOCYBIN IN PSILOCYBE-SEMILANCEATA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON A SILICA COLUMN
    CHRISTIANSEN, AL
    RASMUSSEN, KE
    TONNESEN, F
    JOURNAL OF CHROMATOGRAPHY, 1981, 210 (01): : 163 - 167