Fast determination of tetrafluoroborate by high-performance liquid chromatography using a monolithic column

被引:33
|
作者
Zhou, Shuang [1 ]
Yu, Hong [1 ]
Yang, Ling [1 ]
Ai, Hongjing [1 ]
机构
[1] Harbin Normal Univ, Coll Chem & Chem Engn, Harbin 150025, Peoples R China
关键词
monolithic; high-performance liquid chromatography; tetrafluoroborate; conductivity detection; ionic liquids;
D O I
10.1016/j.chroma.2008.08.048
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fast determination of tetrafluoroborate by high-performance liquid chromatography using a silica-based monolithic column and direct conductivity detection was carried out. Chromatographic separation was performed on a Chromolith Speed ROD RP-18e column (50 mm x 4.6 mm i.d.) with tetrabutylammonium hydroxide (TBA-OH) + phthalic acid as eluent. The effects of eluent concentration, eluent pH, column temperature and flow rate on retention time of tetrafluoroborate were investigated. The optimized chromatographic conditions for determination of tetrafluoroborate were using 0.5 mM TBA-OH + 0.31 mM phthalic acid (pH 5.5) as eluent, column temperature of 30 degrees C and flow rate of 6.0 mL/min. Retention time of tetrafluoroborate was less than 1 min under the conditions. Common anions (Cl-, Br-, NO3- and SO42-) did not interfere with the determination of tetrafluoroborate. Detection limit (S/N = 2) for tetrafluoroborate was 1.4 mg/L. The linear range of calibration curve between peak area and the concentration of tetrafluoroborate was from 1.4 to 100.0 mg/L. The reproducibility was 0.09% and 1.8% (n = 5) relative standard deviation (RSD) for retention time and peak area, respectively. The method has been applied to the determination of tetrafluoroborate in ionic liquids. Recoveries of tetrafluoroborate after spiking were 98.2-101.5%. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:200 / 203
页数:4
相关论文
共 50 条
  • [1] Rapid and Simultaneous Determination of Tetrafluoroborate, Thiocyanate and Hexafluorophosphate by High-Performance Liquid Chromatography Using a Monolithic Column and Direct Conductivity Detection
    Yang, Ling
    Yu, Hong
    Wang, Yaqin
    ANALYTICAL SCIENCES, 2010, 26 (08) : 861 - 866
  • [2] Rapid and Simultaneous Determination of Tetrafluoroborate, Thiocyanate and Hexafluorophosphate by High-Performance Liquid Chromatography Using a Monolithic Column and Direct Conductivity Detection
    Ling Yang
    Hong Yu
    Yaqin Wang
    Analytical Sciences, 2010, 26 : 861 - 866
  • [3] Fast determination of capsaicinoids from peppers by high-performance liquid chromatography using a reversed phase monolithic column
    Barbero, G. F.
    Liazid, A.
    Palma, M.
    Barroso, C. G.
    FOOD CHEMISTRY, 2008, 107 (03) : 1276 - 1282
  • [4] Measurement of Zonisamide by High-Performance Liquid Chromatography using a Monolithic Column
    Heideloff, C.
    Bunch, D. R.
    Wang, S.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A256 - A256
  • [5] Determination of Ochratoxin A in Poultry Feed by High-Performance Liquid Chromatography with a Monolithic Column
    Shar, Zahid Hussain
    Sumbal, Gul Ameer
    Sherazi, Syed Tufail Hussain
    Kara, Huseyin
    Hussain, Masood
    Bhanger, Muhammad Iqbal
    ANALYTICAL LETTERS, 2015, 48 (03) : 396 - 407
  • [6] High-performance liquid chromatography with contactless conductivity detection for the determination of peptides and proteins using a monolithic capillary column
    Kuban, Pavel
    Hauser, Peter C.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1176 (1-2) : 185 - 191
  • [7] Analysis of wine phenolics by high-performance liquid chromatography using a monolithic type column
    Castellari, M
    Sartini, E
    Fabiani, A
    Arfelli, G
    Amati, A
    JOURNAL OF CHROMATOGRAPHY A, 2002, 973 (1-2) : 221 - 227
  • [8] Rapid and simultaneous determination of metabolites of organic solvents in human urine by high-performance liquid chromatography using a monolithic column
    Han, Sang Beom
    Lee, Sang-Ju
    Lee, Cheol-Woo
    Yoon, Seo Hyun
    Joung, Sun Kyung
    Youm, Jeong-Rok
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2006, 19 (05): : 433 - 440
  • [9] RAPID DETERMINATION OF SPHINGANINE AND SPHINGOSINE IN URINE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY USING MONOLITHIC COLUMN
    Lee, Tien Ping
    Saad, Bahruddin
    Khayoon, Wejdan Shakir
    Salleh, Baharuddin
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (17) : 1938 - 1951
  • [10] Analysis of prominent flavonoid aglycones by high-performance liquid chromatography using a monolithic type column
    Repolles, Carme
    Herrero-Martinez, Jose Manuel
    Rafols, Clara