Mask CD compensation method using diffraction intensity for lithography equivalent metrology

被引:0
|
作者
Nagai, Takaharu [1 ]
Sutou, Takanori [1 ]
Inazuki, Yuichi [1 ]
Hashimoto, Hiroyuki [1 ]
Toyama, Nobuhito [2 ]
Morikawa, Yasutaka [1 ]
Mohri, Hiroshi [1 ]
Hayashi, Naoya [1 ]
机构
[1] Dai Nippon Printing Co Ltd, Elect Device Operat, 2-2-1 Fukuoka, Fujimino, Saitama 3568507, Japan
[2] DNP Corp USA, New York, NY 10017 USA
关键词
diffraction intensity; CD-SEM; 3D mask model; MEEF; hole measurement;
D O I
10.1117/12.793063
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In 45nm node and beyond, since mask topography effect is not ignorable, 3D simulation is required for precise printing performance evaluation and mask CD bias optimization. Therefore, the difference between real mask and 3D mask model on simulation needs to be clarified. Verification of 3D mask model by diffraction intensity measurement with AIMS (TM) 45-193i was discussed in our previous works. In various conditions (mask materials, pattern dimensions and CD-SEMs), the diffraction intensity measured on actual masks were agreed to 3D simulations by introducing constant CD offset. The cause of the CD difference was explained to be mainly due to electron beam size by using simple SEM image simulation. In this work, we introduce the new procedure to measure diffraction intensity by AIMS (TM) in order to confirm the CD difference between 3D mask model and CD-SEM more accurately because the agreement of diffraction intensity between AIMS I'm and simulation was not perfect especially for 1(st) order's diffraction. As a result, the value of CD difference was slightly changed on the same mask by using the same CD-SEM. Measured diffraction intensity showed better matching to 3D simulation results with the constant CD offset on all evaluated conditions. Secondary, to confirm how accurately printing performance could be predicted by CD-SEM measurement results, MEEF difference calculated from diffraction intensity between 3D simulation and CD-SEM with the offset was confirmed. Additionally, this method was extended to hole patterns. Measured diffraction intensity was matched to simulation result with the same CD offset with line/space patterns and appropriate corner rounding.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Analysis of defect in extreme UV lithography mask using a modal method based on nodal B-spline expansion
    Edee, K
    Schiavone, P
    Granet, G
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (9A): : 6458 - 6462
  • [32] Automated mask and wafer defect classification using a novel method for generalized CD variation measurements
    Verechagin, V.
    Kris, R.
    Schwarzband, I.
    Milstein, A.
    Cohen, B.
    Shkalim, A.
    Levy, S.
    Price, D.
    Bal, E.
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XXXII, 2018, 10585
  • [33] A novel overlay process for imprint lithography using load release and alignment error pre-compensation method
    Shao, Jinyou
    Ding, Yucheng
    Tang, Yiping
    Liu, Hongzhong
    Lu, Bingheng
    Cui, Dongyin
    MICROELECTRONIC ENGINEERING, 2008, 85 (01) : 168 - 174
  • [34] Numerical tilting compensation in microscopy based on wavefront sensing using transport of intensity equation method
    Hu, Junbao
    Meng, Xin
    Wei, Qi
    Kong, Yan
    Jiang, Zhilong
    Xue, Liang
    Liu, Fei
    Liu, Cheng
    Wang, Shouyu
    JOURNAL OF OPTICS, 2018, 20 (03)
  • [35] Focus-shift compensation in high intensity focused ultrasound using the time reversal method
    Lin, Weijun (linwj@mail.ioa.ac.cn), 2017, Science Press (42):
  • [36] Investigation of multi-intensity compensation for a medical proton therapy facility using the quadrupole scanning method
    Zeng, Xianhu
    Song, Yuntao
    Zheng, Jinxing
    Jiang, Feng
    Wang, Ming
    Li, Ming
    Han, Manfen
    Zhu, Lei
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 935 : 161 - 166
  • [37] Fast rigorous simulation of mask diffraction using the waveguide method with parallelized decomposition technique - art. no. 679206
    Shao, Feng
    Evanschitzky, Peter
    Reibold, David
    Erdmann, Andreas
    EMLC 2008: 24TH EUROPEAN MASK AND LITHOGRAPHY CONFERENCE, 2008, 6792 : 79206 - 79206
  • [38] Depth and intensity of equivalent current dipoles estimated through an inverse analysis of surface electromyograms using the image method
    K. Saitou
    T. Masuda
    M. Okada
    Medical & Biological Engineering & Computing, 1999, 37 : 720 - 726
  • [39] Depth and intensity of equivalent current dipoles estimated through an inverse analysis of surface electromyograms using the image method
    Saitou, K
    Masuda, T
    Okada, M
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (06) : 720 - 726
  • [40] Depth and intensity of equivalent current dipoles estimated through an inverse analysis of surface electromyograms using the image method
    Inst. of Health and Sport Sciences, University of Tsukuba, Tsukuba, Ibaraki, Japan
    Med. Biol. Eng. Comput., 6 (720-726):