Voltammetric determination of disinfectants at multiwalled carbon nanotube modified glassy carbon electrode

被引:0
|
作者
Baranowska, I. [1 ]
Bijak, K. [1 ]
机构
[1] Silesian Tech Univ, Fac Chem, Dept Analyt Chem, PL-44100 Gliwice, Poland
关键词
differential pulse voltammetry; carbon nanotubes; disinfectant; ELECTROCHEMICAL DETERMINATION; TRICLOSAN; FILM; 2-MERCAPTOBENZOTHIAZOLE; 4-CHLORO-3-METHYLPHENOL;
D O I
10.1134/S106193481310002X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The voltammetric method for simultaneous determination of some disinfectants at glassy carbon electrode modified with multiwalled carbon nanotubes is presented. The examined compounds are: 2-phenylphenol, 4-chloro-3-methylphenol, triclosan (5-chloro-2-(2,4-dichlorophenoxy)phenol and 2-mercaptobenzothiazole. The measurements has been performed using cyclic voltammetry and differential pulse voltammetry in Britton-Robinson buffers as supporting electrolytes. The modification of electrode surface with multiwalled carbon nanotubes enhances the peak current. It is possible to measure mixtures of two compounds (2-phenylphenol and 2-mercaptobenzothiazole, 4-chloro-3-methylphenol and 2-mercaptobenzothiazole, triclosan and 2-mercaptobenzothiazole) in the solution of pH 9.9, which provides the best separation of oxidation peaks.
引用
收藏
页码:891 / 895
页数:5
相关论文
共 50 条
  • [41] Multiwalled carbon nanotube/ionic liquid paste electrode for voltammetric determination of sulfachlorpyridazine
    Aleixo, Herbert
    Okumura, Leonardo Luiz
    Gurgel, Alexandre
    Souza Silva, Astrea Filomena
    Diniz, Juliana Aparecida
    ANALYTICAL METHODS, 2019, 11 (13) : 1743 - 1750
  • [42] Carbon nanotube-modified glassy carbon electrode for anodic stripping voltammetric detection of Uranyle
    Ahmad Nozad Golikand
    Mehdi Asgari
    Mohammad Ghannadi Maragheh
    Elaheh Lohrasbi
    Journal of Applied Electrochemistry, 2009, 39 : 65 - 70
  • [43] Carbon nanotube-modified glassy carbon electrode for anodic stripping voltammetric detection of Uranyle
    Golikand, Ahmad Nozad
    Asgari, Mehdi
    Maragheh, Mohammad Ghannadi
    Lohrasbi, Elaheh
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (01) : 65 - 70
  • [44] Voltammetric Determination of Caffeine at Pt/Carbon Nanotubes Composite Modified Glassy Carbon Electrode
    Wei, Yingliang
    Zhang, Luping
    Shao, Chen
    Li, Chao
    CHEMIA ANALITYCZNA, 2009, 54 (04): : 607 - 617
  • [45] A Mexacarbate Electrochemical Biosensor on Carbon Materials Based on a Functionalized Multiwalled Carbon Nanotube Modified Glassy Carbon Electrode
    Tharini, J.
    Chen, Tse-Wei
    Chen, Shen-Ming
    Saraswathi, R.
    Elshikh, Mohamed S.
    Darwish, Noura M.
    Rwei, Syang-Peng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (08): : 8311 - 8325
  • [46] Voltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2015, 2015
  • [47] Voltammetric Determination of Lead and Copper in Wine by Modified Glassy Carbon Electrode
    Department of Pharmacy, Faculty of Medicine, University of Banja Luka, Save Mrkalja 14, Banja Luka
    78000, Bosnia and Herzegovina
    不详
    11000, Serbia
    不详
    11000, Serbia
    不详
    78000, Bosnia and Herzegovina
    Anal. Sci., 2 (353-358):
  • [48] Voltammetric Determination of Tenoxicam in Drug Formulation at Modified Glassy Carbon Electrode
    Sadikoglu, Murat
    Cabuk, Ahmet
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (05): : 4508 - 4519
  • [49] Voltammetric Determination of Epinephrine using a Thiourea Modified Glassy Carbon Electrode
    Yazdely, Malihe Ahmadian
    Taher, Mohammad Ali
    Tajik, Somayeh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2013, 5 (04): : 517 - 527
  • [50] Diaminoanthraquinone polymer modified glassy carbon electrode for the voltammetric determination of imidacloprid
    Soman, Sithara
    Ramakrishnan, Kala
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2024, 54 (12) : 2831 - 2843