Measurement of Heart Rate and Respiratory Rate Using a Textile-Based Wearable Device in Heart Failure Patients

被引:17
|
作者
Chiarugi, F. [1 ,2 ]
Karatzanis, I. [2 ]
Zacharioudakis, G. [2 ]
Meriggi, P. [3 ]
Rizzo, F.
Stratakis, M. [4 ]
Louloudakis, S. [4 ]
Biniaris, C. [5 ]
Valentini, M. [6 ]
Di Rienzo, M. [3 ,7 ]
Parati, G. [6 ,7 ]
机构
[1] Fdn Res & Technol Hellas, Inst Comp Sci, Biomed Informat Lab, POB 1385 N Plastira 100, GR-70013 Iraklion, Crete, Greece
[2] Fdn Res & Technol Hellas, Inst Comp Sci, Iraklion, Greece
[3] Don Carlo Gnochi Fdn, Biomed Technol Dept, Milan, Italy
[4] FORTHnet SA, Iraklion, Greece
[5] Virtual Med World Solut, Romsey, Hants, England
[6] San Luca Hosp, Inst Auxol Italiano, Dept Cardiol, Milan, Italy
[7] Univ Milano Bicocca, Dept Clin Med, Milan, Italy
关键词
D O I
10.1109/CIC.2008.4749188
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Changes in heart rate (HR) and respiratory rate (RespR) may be used as markers of early decompensation in chronic heart failure (CHF) patients monitored at home. Aiming at improving quality of care and at reducing hospitalization rate and health care costs in CHF, progress in technology has led to the development of small portable and even wearable devices for the acquisition and transmission of relevant vital signs to a remote monitoring centre. This paper describes a signal acquisition and processing system, based on a wearable textile-based device with sensors for the measurement of one-lead ECG and chest movement, and focuses on the algorithms for HR and RespR evaluation. An electronic board collects and transmits these signals to a PDA, which sends them via Wi-Fi to a home gateway where the HR and the RespR time series are produced. The home gateway packs the data with other vital signs collected by using different devices and sends them in XML, format to a central repository where a clinical decision support system can use them for the defection of early decompensation episodes. The system has successfully overcome a preliminary test phase and is ready for more extensive tests in a real clinical environment.
引用
收藏
页码:901 / +
页数:2
相关论文
共 50 条
  • [41] HEART RATE VARIABILITY MEASURED BY A NOVEL DEVICE IN PARTICIPANTS WITH HEART FAILURE
    Matthew, D.
    Rosen, S.
    Sandercock, G.
    Brodie, D.
    ATHEROSCLEROSIS, 2012, 223 (02) : 533 - 533
  • [42] Using the smartphone camera to monitor heart rate and rhythm in heart failure patients
    Lagido, R. B.
    Lobo, J.
    Leite, S.
    Sousa, C.
    Ferreira, L.
    Silva-Cardoso, J.
    2014 IEEE-EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL AND HEALTH INFORMATICS (BHI), 2014, : 556 - 559
  • [43] Emerging Paradigms in Fetal Heart Rate Monitoring: Evaluating the Efficacy and Application of Innovative Textile-Based Wearables
    Ahmed, Md Raju
    Newby, Samantha
    Potluri, Prasad
    Mirihanage, Wajira
    Fernando, Anura
    SENSORS, 2024, 24 (18)
  • [44] Audit of heart failure patients using ESC guidelines for heart rate optimization
    Baig, M.
    Boardman, J.
    Sajjid, J.
    Potluri, R.
    Carty, R.
    Mushawar, S.
    Irwin, B.
    EUROPEAN JOURNAL OF HEART FAILURE, 2013, 12 : S91 - S91
  • [45] Prognostic impact of maximal nocturnal heart rate in heart failure patients with an implantable electronic device
    Duarte, F. Fabiana
    Santos, I.
    Barradas, M. I.
    Oliveira, L.
    Serena, C.
    Monteiro, A.
    Machado, C.
    Dourado, R.
    Santos, E.
    Tavares, A.
    Martins, D.
    EUROPEAN JOURNAL OF HEART FAILURE, 2024, 26 : 35 - 35
  • [46] Design and Implementation of Heart Rate Measurement Device Using Wireless System
    Hazari, Md Rifat
    Jahan, Effat
    Amin, Md Rashedul
    Alam, Md Ashraful
    2014 INTERNATIONAL CONFERENCE ON INFORMATICS, ELECTRONICS & VISION (ICIEV), 2014,
  • [47] Development and Evaluation of a Contactless Heart Rate Measurement Device Based on rPPG
    Ahmadi, Nur
    Al Farisyi, M. Salman
    Prihatmoko, M. Dzaky
    Hyanda, M. Heronan
    Muhaimin, Habibur
    Mulyawan, Rahmat
    Charlton, Peter H.
    Adiono, Trio
    2022 29TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS (IEEE ICECS 2022), 2022,
  • [48] Measurement of Heart Rate Using Photoplethysmography
    Saquib, Nazmus
    Papon, Md Tarikul Islam
    Ahmad, Ishtiyaque
    Rahman, Ashikur
    2015 INTERNATIONAL CONFERENCE ON NETWORKING SYSTEMS AND SECURITY (NSYSS), 2015, : 158 - 163
  • [49] Evaluation of measurement accuracy of wearable devices for heart rate variability
    Li, Xiangchen
    Song, Yuting
    Wang, Huang
    Su, Xinyu
    Wang, Mengyao
    Li, Jing
    Ren, Zhiqiang
    Zhong, Daidi
    Huang, Zhiyong
    ISCIENCE, 2023, 26 (11)
  • [50] Investigating the association of anxiety disorders with heart rate variability measured using a wearable device
    Tomasi, Julia
    Zai, Clement C.
    Zai, Gwyneth
    Herbert, Deanna
    Richter, Margaret A.
    Mohiuddin, Ayeshah G.
    Tiwari, Arun K.
    Kennedy, james L.
    JOURNAL OF AFFECTIVE DISORDERS, 2024, 351 : 569 - 578