Assessment of Lens Center Using Optical Coherence Tomography, Magnetic Resonance Imaging, and Photographs of the Anterior Segment of the Eye

被引:7
|
作者
Lee, Yong Eun [1 ]
Joo, Choun-Ki [1 ]
机构
[1] Catholic Univ Korea, Seoul St Marys Hosp Eye Inst SSEI, Dept Ophthalmol & Visual Sci, Coll Med, Seoul 137701, South Korea
关键词
cataract; lens center; capsulorhexis; laser surgery; lens capsule; POSTERIOR CAPSULE OPACIFICATION; PHARMACOLOGICALLY DILATED CONDITIONS; CONTINUOUS CURVILINEAR CAPSULORHEXIS; FEMTOSECOND LASER CAPSULOTOMY; SIZE; DECENTRATION; DIAMETER;
D O I
10.1167/iovs.15-17454
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To determine the nearest marker for evaluating the center of the crystalline lens using optical coherence tomography (OCT), magnetic resonance imaging (MRI), and photographs. METHODS. Optical coherence tomography scans of human eyes were obtained in vivo during femtosecond laser-assisted cataract surgery. From axial and sagittal images, the distance of the angle center (AC) and pupil center (PC) from the scanned capsule center (SCC) was calculated. From pre- and postoperative photographs, the distance of the PC and limbal center (LC) from the intraocular lens (IOL) center was calculated, and distance between each center on the lens equatorial plane was compared. After combination of pre- and postoperative images, we arranged the centers in order of distance from the IOL center. High-resolution MRI was performed in pig eyes ex vivo to confirm the exact location of the lens center relative to other centers. RESULTS. In human OCT scans and photographs (n = 76), the IOL center to AC distance was 0.22 6 +/- 0.13 mm, the IOL center to SCC distance was 0.22 +/- 0.12 mm, the IOL center to PC distance was 0.25 +/- 0.17 mm, and the IOL center to LC distance was 0.30 +/- 0.18 mm. The AC and SCC were significantly closer to the IOL center than the PC or LC. In MRI (n = 54 images), the lens center to AC distance was 0.90 +/- 0.58 mm, and the lens center to PC distance was 1.53 +/- 0.87 mm (D distance = 0.63 +/- 0.69 mm, P = 0.000). CONCLUSIONS. Optical coherence tomography, MRI, and photographs of the anterior segment revealed that the AC is the nearest marker to the center of the lens equator.
引用
收藏
页码:5512 / 5518
页数:7
相关论文
共 50 条
  • [21] Lens thickness assessment : anterior segment optical coherence tomography versus A-scan ultrasonography
    Nikoo Hamzeh
    Sasan Moghimi
    Golshan Latifi
    Massood Mohammadi
    Nassim Khatibi
    Shan C.Lin
    International Journal of Ophthalmology, 2015, (06) : 1151 - 1155
  • [22] Lens thickness assessment: anterior segment optical coherence tomography versus A-scan ultrasonography
    Hamzeh, Nikoo
    Moghimi, Sasan
    Latifi, Golshan
    Mohammadi, Massood
    Khatibi, Nassim
    Lin, Shan C.
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (06) : 1151 - 1155
  • [23] Three-dimensional in vivo imaging of human anterior eye segment with optical coherence tomography
    Hong, Jiaxu
    Liu, Xiaoyu
    Wen, Wen
    Fan, Yubo
    Sun, Xinghuai
    Xu, Jianjiang
    ISBE 2011: 2011 INTERNATIONAL CONFERENCE ON BIOMEDICINE AND ENGINEERING, VOL 1, 2011, : 487 - 492
  • [24] Evaluation of Intraocular Lens Tilt With Anterior Segment Optical Coherence Tomography
    Kumar, Dhivya Ashok
    Agarwal, Amar
    Prakash, Gaurav
    Jacob, Soosan
    Saravanan, Yoga
    Agarwal, Athiya
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (03) : 406 - 412
  • [25] Anterior Segment Optical Coherence Tomography as a Screening Tool for the Assessment of the Anterior Segment Angle
    Pekmezci, Melike
    Porco, Travis C.
    Lin, Shan C.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2009, 40 (04) : 389 - 398
  • [26] Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment
    Dada, Tanuj
    Sihota, Ramanjit
    Gadia, Ritu
    Aggarwal, Anand
    Mandal, Subrata
    Gupta, Viney
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05): : 837 - 840
  • [27] Anterior segment optical coherence tomography for imaging the anophthalmic socket
    Sagoo, Mandeep S.
    Bell, Stephen
    Carpenter, David
    Bott, Gordon
    Hara, Naoko
    Schmidt, Udo
    Restori, Marie
    EYE, 2020, 34 (08) : 1479 - 1481
  • [28] Anterior segment optical coherence tomography for imaging the anophthalmic socket
    Mandeep S. Sagoo
    Stephen Bell
    David Carpenter
    Gordon Bott
    Naoko Hara
    Udo Schmidt
    Marie Restori
    Eye, 2020, 34 : 1479 - 1481
  • [29] Optical Coherence Tomography Angiography for Anterior Segment Vasculature Imaging
    Ang, Marcus
    Sim, Dawn A.
    Keane, Pearse A.
    Sng, Chelvin C. A.
    Egan, Catherine A.
    Tufail, Adnan
    Wilkins, Mark R.
    OPHTHALMOLOGY, 2015, 122 (09) : 1740 - 1747
  • [30] Use of anterior segment optical coherence tomography in a penetrating eye injury
    Madhusudhana, K. C.
    Hossain, P.
    Thiagarajan, M.
    Newsom, R. S. B.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (07) : 982 - 983