Variation of rotation moment arms with hip flexion

被引:214
|
作者
Delp, SL [1 ]
Hess, WE
Hungerford, DS
Jones, LC
机构
[1] Stanford Univ, Dept Mech Engn, Biomech Engn Div, Stanford, CA 94305 USA
[2] Northwestern Univ, Dept Biomed Engn, Evanston, IL 60208 USA
[3] Johns Hopkins Univ, Dept Orthopaed Surg, Baltimore, MD USA
关键词
hip; muscle; moment arm; cerebral palsy; gait;
D O I
10.1016/S0021-9290(99)00032-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Excessive flexion and internal rotation of the hip is a common gait abnormality among individuals with cerebral palsy. The purpose of this study was to examine the influence of hip flexion on the rotational moment arms of the hip muscles. We hypothesized that flexion of the hip would increase internal rotation moment arms and decrease external rotation moment arms of the primary hip rotators. To test this hypothesis we measured rotational moment arms of the gluteus maximus (six compartments), gluteus medius (four compartments), gluteus minimus (three compartments) iliopsoas, piriformis, quadratus femoris, obturator internus, and obturator externus. Moment arms were measured at hip flexion angles of 0, 20, 45, 60, and 90 degrees in four cadavers. A three-dimensional computer model of the hip muscles was developed and compared to the experimental measurements. The experimental results and the computer model showed that the internal rotation moment arms of some muscles increase with flexion; the external rotation moment arms of other muscles decrease, and some muscles switch from external rotation to internal rotation as the hip is flexed. This trend toward internal rotation with hip flexion was apparent in 15 of the 18 muscle compartments we examined, suggesting that excessive hip flexion may exacerbate internal rotation of the hip. The gluteus maximus was found to have a large capacity for external rotation. Enhancing the activation of the gluteus maximus, a muscle that is frequently underactive in persons with cerebral palsy, may help correct excessive flexion and internal rotation of the hip. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:493 / 501
页数:9
相关论文
共 50 条
  • [31] Adverse effects of total hip arthroplasty on the hip abductor and adductor muscle lengths and moment arms during gait
    Hu, Xiangjun
    Zheng, Nan
    Hsu, Wei-Chun
    Zhang, Jingwei
    Li, Huiwu
    Chen, Yunsu
    Dai, Kerong
    Tsai, Tsung-Yuan
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [32] Axial Rotation Moment Arms of the Shoulder Musculature After Reverse Total Shoulder Arthroplasty
    Ackland, David C.
    Richardson, Martin
    Pandy, Marcus G.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (20): : 1886 - 1895
  • [33] Trochanteric transfer in total hip replacement: Effects on the moment arms and force-generating capacities of the hip abductors
    Free, SA
    Delp, SL
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1996, 14 (02) : 245 - 250
  • [34] FLEXION AND EXTENSION AT HIP
    MILCH, H
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1962, 182 (10): : 1060 - &
  • [35] MOMENT ARMS OF HIP ABDUCTOR AND ADDUCTOR MUSCLES MEASURED INVIVO BY COMPUTED-TOMOGRAPHY
    NEMETH, G
    OHLSEN, H
    CLINICAL BIOMECHANICS, 1989, 4 (03) : 133 - 136
  • [36] TRANSFER OF THE RECTUS FEMORIS - EFFECTS OF TRANSFER SITE ON MOMENT ARMS ABOUT THE KNEE AND HIP
    DELP, SL
    RINGWELSKI, DA
    CARROLL, NC
    JOURNAL OF BIOMECHANICS, 1994, 27 (10) : 1201 - +
  • [37] Effect of abduction and external rotation of the hip joint on muscle onset time during prone hip extension with knee flexion
    Suehiro, Tadanobu
    Mizutani, Masatoshi
    Ishida, Hiroshi
    Kobara, Kenichi
    Fujita, Daisuke
    Osaka, Hiroshi
    Takahashi, Hisashi
    Watanabe, Susumu
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (01) : 289 - 291
  • [38] Hip MRI in flexion abduction external rotation for assessment of the ischiofemoral interval in patients with hip pain-a feasibility study
    Heimann, Alexander F.
    Walther, Jonas
    Tannast, Moritz
    Schwab, Joseph M.
    Wagner, Moritz
    Brunner, Alexander
    Lerch, Till D.
    Steppacher, Simon D.
    Vavron, Peter
    Schmaranzer, Ehrenfried
    Schmaranzer, Florian
    INSIGHTS INTO IMAGING, 2023, 14 (01)
  • [39] Simulation of hip bony range of motion (BROM) corresponds to the observed functional range of motion (FROM) for pure flexion, internal rotation in deep flexion, and external rotation in minimal flexion-extension – A cadaver study
    Palit, Arnab
    Williams, Mark A.
    Kiraci, Ercihan
    Seemala, Vineet
    Gupta, Vatsal
    Pierrepont, Jim
    Plaskos, Christopher
    King, Richard
    Computers in Biology and Medicine, 2024, 183
  • [40] Investigation of the use of inertial sensing equipment for the measurement of hip flexion and pelvic rotation in horse riders
    Gandy, E. A.
    Bondi, A.
    Pigott, T. M. C.
    Smith, G.
    McDonald, S.
    COMPARATIVE EXERCISE PHYSIOLOGY, 2018, 14 (02) : 99 - 110