Validation of a Hyperspectral Imaging System for Color Measurement of In-Vivo Dental Structures

被引:5
|
作者
Tejada-Casado, Maria [1 ,2 ]
Ghinea, Razvan [1 ,2 ]
Angel Martinez-Domingo, Miguel [1 ]
Perez, Maria M. [1 ,2 ]
Cardona, Juan C. [1 ,2 ]
Ruiz-Lopez, Javier [1 ,2 ]
Javier Herrera, Luis [2 ,3 ]
机构
[1] Univ Granada, Fac Sci, Dept Opt, Ibs Granada, Campus Fuentenueva S-N, Granada 18071, Spain
[2] Inst Invest Biosanitaria Ibs GRANADA, Granada 18012, Spain
[3] Univ Granada, Comp Architecture & Technol Dept, Granada 18071, Spain
关键词
hyperspectral imaging; color; dentistry; TOOTH COLOR; THICKNESS; TRANSLUCENCY; ZIRCONIA; SHADE;
D O I
10.3390/mi13111929
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A full comprehension of colorimetric relationships within and between teeth is key for aesthetic success of a dental restoration. In this sense, hyperspectral imaging can provide point-wise reliable measurements of the tooth surface, which can serve for this purpose. The aim of this study was to use a hyperspectral imaging system for the colorimetric characterization of 4 in-vivo maxillary anterior teeth and to cross-check the results with similar studies carried out with other measuring systems in order to validate the proposed capturing protocol. Hyperspectral reflectance images (Specim IQ), of the upper central (UCI) and lateral incisors (ULI), were captured on 30 participants. CIE-L*a*b* values were calculated for the incisal (I), middle (M) and cervical (C) third of each target tooth. Delta E-ab* and Delta E-00 total color differences were computed between different tooth areas and adjacent teeth, and evaluated according to the perceptibility (PT) and acceptability (AT) thresholds for dentistry. Non-perceptible color differences were found between UCIs and ULIs. Mean color differences between UCI and ULI exceeded AT (Delta E-ab* = 7.39-7.42; Delta E-00 = 5.71-5.74) in all cases. Large chromatic variations between I, M and C areas of the same tooth were registered (Delta E-ab* = 5.01-6.07 and Delta E-00 = 4.07-5.03; Delta E-ab* = 5.80-8.16 and Delta E-00 = 4.37-5.15; and Delta E-ab* = 5.42-5.92 and Delta E-00 = 3.87-4.16 between C and M, C and I and M and I, respectively). The use of a hyperspectral camera has proven to be a reliable and effective method for color evaluation of in-vivo natural teeth.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Distributed image reconstruction for an in-vivo mouse imaging system
    Lee, SC
    Han, JY
    Chun, IK
    Lee, SY
    Cho, MH
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 639 - 646
  • [22] Evaluation and consistency calibration of hyperspectral imaging system based on liquid crystal tunable filter for fabric color measurement
    Zhang, Jianxin
    Liu, Yue
    Zhang, Xinen
    Hu, Xudong
    COLOR RESEARCH AND APPLICATION, 2022, 47 (02): : 401 - 415
  • [23] Measurement method of MRED of color imaging system
    School of Optoelectronic Engineering, Xi'an Technological University, Xi'an
    710032, China
    不详
    710065, China
    Hongwai yu Jiguang Gongcheng Infrared Laser Eng., 5 (1633-1637):
  • [24] Validation and experiment plans for a space based hyperspectral imaging system
    Cooley, T
    IGARSS 2000: IEEE 2000 INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOL I - VI, PROCEEDINGS, 2000, : 1382 - 1384
  • [25] 3-DIMENSIONAL ECHOCARDIOGRAPHIC MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN-VIVO - VALIDATION WITH MAGNETIC-RESONANCE-IMAGING
    EMGE, FK
    CHUNG, KY
    PARKS, WJ
    MUKUNDAN, S
    OSHINSKI, JN
    PETTIGREW, RI
    CIRCULATION, 1994, 90 (04) : 337 - 337
  • [26] COLOR DOPPLER IMAGING AND IN-VIVO ASSESSMENT OF THE ANATOMY AND PHYSIOLOGY OF THE EARLY UTEROPLACENTAL CIRCULATION
    JAFFE, R
    WOODS, JR
    FERTILITY AND STERILITY, 1993, 60 (02) : 293 - 297
  • [27] In-Vivo and Ex-Vivo Tissue Analysis through Hyperspectral Imaging Techniques: Revealing the Invisible Features of Cancer
    Halicek, Martin
    Fabelo, Himar
    Ortega, Samuel
    Callico, Gustavo M.
    Fei, Baowei
    CANCERS, 2019, 11 (06)
  • [28] Research on Wide Format Hyperspectral Color Measurement System for Printed Matter
    Chen, Jing-xue
    Wei, Yu-cheng
    Zhou, Jian-kang
    Zhu, Jia-cheng
    Shen, Wei-min
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2025, 45 (02) : 312 - 321
  • [29] IN-VIVO MEASUREMENT OF VITREOUS MOTION USING AN ULTRASOUND IMAGING VELOCIMETRY TECHNIQUE
    Rossi, Tommaso
    Querzoli, Giorgio
    Repetto, Rodolfo
    Stocchino, Alessandro
    Pasqualitto, Giacomo
    Lossa, Mario
    Placentino, Luca
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 1179 - 1180
  • [30] Toward in-vivo diagnosis of skin cancer using multimode imaging dermoscopy: (I) Clinical system development and validation
    MacKinnon, Nicholas
    Vasefi, Fartash
    Farkas, Daniel L.
    IMAGING, MANIPULATION, AND ANALYSIS OF BIOMOLECULES, CELLS, AND TISSUES XII, 2014, 8947