A patient-specific lumped-parameter model of coronary circulation

被引:55
|
作者
Zheng Duanmu [1 ]
Min Yin [1 ]
Fan, Xueling [1 ]
Yang, Xilan [2 ]
Luo, Xiaoyu [3 ]
机构
[1] Xi An Jiao Tong Univ, Sch Aerosp Engn, State Key Lab Strength & Vibrat Mech Struct, Xian, Shaanxi, Peoples R China
[2] Nanjing Med Univ, Affiliated Hosp 2, Nanjing, Jiangsu, Peoples R China
[3] Univ Glasgow, Sch Math & Stat, Glasgow, Lanark, Scotland
来源
SCIENTIFIC REPORTS | 2018年 / 8卷
关键词
PULSATILE BLOOD-FLOW; CAROTID-ARTERY; NUMERICAL-SIMULATION; FLUID-DYNAMICS; PRESSURE; TREE; WILLIS; CIRCLE; VALIDATION; STENOSIS;
D O I
10.1038/s41598-018-19164-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A new lumped-parameter model for coronary hemodynamics is developed. This model is developed for the whole coronary network based on CT scans of a patient-specific geometry including the right coronary tree, which is absent in many previous mathematical models. The model adopts the structured tree model boundary conditions similar to the work of Olufsen et al., thus avoiding the necessity of invasive perfusion measurements. In addition, we also incorporated the effects of the head loss at the two inlets of the large coronary arteries for the first time. The head loss could explain the phenomenon of a sudden increase of the resistance at the inlet of coronary vessel. The estimated blood pressure and flow rate results from the model agree well with the clinical measurements. The computed impedances also match the experimental perfusion measurement. The effects of coronary arterial stenosis are considered and the fractional flow reserve and relative flow in the coronary vessels for a stenotic vessel computed in this model show good agreement with published experimental data. It is believed that the approach could be readily translated to clinical practice to facilitate real time clinical diagnosis.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] A lumped-parameter model for kidney pressure during stone removal
    Williams, J. G.
    Rouse, L.
    Turney, B. W.
    Waters, S. L.
    Moulton, D. E.
    IMA JOURNAL OF APPLIED MATHEMATICS, 2020, 85 (05) : 703 - 723
  • [42] LUMPED-PARAMETER MODEL OF MASS-TRANSFER IN HEMODIALYZER WITH ULTRAFILTRATION
    ZHANG, FB
    ZHANG, GL
    CHEN, T
    WANG, ST
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 1995, 3 (01) : 57 - 62
  • [43] GLOBAL LUMPED-PARAMETER MODEL WITH PHYSICAL REPRESENTATION FOR UNBOUNDED MEDIUM
    PARONESSO, A
    WOLF, JP
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1995, 24 (05): : 637 - 654
  • [44] Identification of a lumped-parameter model for golf balls in normal impact
    Nakai, K.
    Yokoyama, T.
    ADVANCES IN EXPERIMENTAL MECHANICS V, 2007, 7-8 : 237 - +
  • [45] OPTIMAL LUMPED-PARAMETER PERIODIC PROCESSES
    FARHADPOUR, FA
    INTERNATIONAL JOURNAL OF CONTROL, 1986, 44 (01) : 91 - 115
  • [46] A lumped-parameter mechanical model of human ear for sound transmission
    Feng, B
    Gan, RZ
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 267 - 268
  • [47] A lumped-parameter electro-thermal model for cylindrical batteries
    Lin, Xinfan
    Perez, Hector E.
    Mohan, Shankar
    Siegel, Jason B.
    Stefanopoulou, Anna G.
    Ding, Yi
    Castanier, Matthew P.
    JOURNAL OF POWER SOURCES, 2014, 257 : 1 - 11
  • [48] NONLINEAR, LUMPED-PARAMETER TRANSFORMER MODEL-REDUCTION TECHNIQUE
    DEGENEFF, RC
    GUTIERREZ, MR
    VAKILIAN, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (02) : 862 - 868
  • [49] A Lumped-Parameter Model for Adaptive Dynamic MR Damper Control
    Case, David
    Taheri, Behzad
    Richer, Edmond
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2015, 20 (04) : 1689 - 1696
  • [50] TRANS-CAPILLARY FLUID EXCHANGE - LUMPED-PARAMETER MODEL
    MOISEEVA, IN
    BIOFIZIKA, 1984, 29 (01): : 126 - 129