Twenty-four-hour pattern of intraocular pressure in the aging population

被引:0
|
作者
Liu, JHK [1 ]
Kripke, DF
Twa, MD
Hoffman, RE
Mansberger, SL
Rex, KM
Girkin, CA
Weinreb, RN
机构
[1] Univ Calif San Diego, Dept Ophthalmol, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Psychiat, La Jolla, CA 92093 USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. TO characterize the 24-hour pattern of intraocular pressure (IOP) in a sample of the aging human population. METHODS. Twenty-one healthy volunteers 50 to 69 rears of age were housed in a sleep laboratory fur 24 hours. Experimental conditions were strictly controlled with a 16-hour light period :md an 8-hour dark period. Sleep was encouraged in the dark period. Intraocular pressure was measured using a pneumatonometer every 2 hours (total of 12 times). Measurements were taken in both the sitting position and the supine position during the light/wake period but only in the supine position during the dark period. RESULTS. When the sitting IOP data from the light/wake period and the supine IOP data from the dark period were considered, elevation and reduction of IOP occurred around the scheduled lights-off and lights-on transitions, respectively. Mean IOP in the dark period was significantly higher than mean IOP in the light/wake period. The trough appeared at the end of the light/wake period, and the peak appeared at the beginning of the dark period. The magnitude of trough-peak difference was 8.6 +/- 0.8 mm Hg (mean +/- SEM). Cosine fits of 24-hour IOP data showed a significant 24-hour rhythm. When IOP data from just the supine position were analyzed, the trough-peak IOP difference was 3.4 +/- 0.7 mm Hg, with similar clock times for the trough and the peak. Cosine fits of supine IOP data showed no statistically significant 24-hour rhythm. CONCLUSIONS. Nocturnal elevation of IOP occurred in this sample of the aging population. The trough of IOP appeared at the end of the light/wake period, and the peak appeared at the beginning of the dark period. The main factor in the nocturnal IOP elevation appeared to be the shift from daytime upright posture to supine posture at night.
引用
收藏
页码:2912 / 2917
页数:6
相关论文
共 50 条
  • [21] Twenty-four-hour intraocular pressure and ocular perfusion pressure characteristics in newly diagnosed patients with normal tension glaucoma
    L Quaranta
    A Katsanos
    I Riva
    A Dastiridou
    F Oddone
    G Roberti
    A G P Konstas
    Eye, 2016, 30 : 1481 - 1489
  • [22] Twenty-four-hour intraocular pressure and ocular perfusion pressure characteristics in newly diagnosed patients with normal tension glaucoma
    Quaranta, L.
    Katsanos, A.
    Riva, I.
    Dastiridou, A.
    Oddone, F.
    Roberti, G.
    Konstas, A. G. P.
    EYE, 2016, 30 (11) : 1481 - 1489
  • [23] Twenty-four-hour ambulatory blood pressure monitoring in infants and toddlers
    Nataša Marčun Varda
    Alojz Gregorič
    Pediatric Nephrology, 2005, 20 : 798 - 802
  • [24] Twenty-four-hour automated blood pressure monitoring as a predictor of preeclampsia
    Brown, MA
    Bowyer, L
    McHugh, L
    Davis, GK
    Mangos, GJ
    Jones, M
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2001, 185 (03) : 618 - 622
  • [25] Twenty-four-hour ambulatory blood pressure monitoring in young children
    Gellermann, J
    Kraft, S
    Ehrich, JHH
    PEDIATRIC NEPHROLOGY, 1997, 11 (06) : 707 - 710
  • [26] Twenty-four-hour ambulatory blood pressure monitoring in young children
    Jutta Gellermann
    Stephan Kraft
    Jochen H. H. Ehrich
    Pediatric Nephrology, 1997, 11 : 707 - 710
  • [27] Twenty-four-hour blood pressure changes in the course of lacunar disease
    Yamamoto, Y
    Akiguchi, I
    Oiwa, K
    Hayashi, M
    Imai, K
    CEREBROVASCULAR DISEASES, 2001, 11 (02) : 100 - 106
  • [28] Twenty-four-hour ambulatory blood pressure monitoring in infants and toddlers
    Varda, NM
    Gregoric, A
    PEDIATRIC NEPHROLOGY, 2005, 20 (06) : 798 - 802
  • [29] Twenty-four-hour ambulatory blood pressure monitoring in atrial fibrillation
    Olsen, R
    Amlie, A
    Omvik, P
    BLOOD PRESSURE MONITORING, 2002, 7 (03) : 149 - 156
  • [30] Twenty-four-hour ambulatory blood pressure evaluation of antihypertensive agents
    Zanchetti, A
    JOURNAL OF HYPERTENSION, 1997, 15 : S21 - S25