Direct and Indirect Flap Measurements in Femtosecond Laser-Assisted In Situ Keratomileusis

被引:0
|
作者
Crispim, Joao [1 ,2 ]
Allemann, Norma [1 ,2 ]
Hallak, Joelle A. [1 ]
Azar, Dimitri T. [1 ]
De La Cruz, Jose [1 ]
机构
[1] Univ Illinois, Illinois Eye & Ear Infirm, Dept Ophthalmol & Visual Sci, 1855 W Taylor St, Chicago, IL 60612 USA
[2] Univ Fed Sao Paulo, Dept Ophthalmol & Visual Sci, Sao Paulo, Brazil
关键词
laser in situ keratomileusis; flap thickness; femtosecond laser; ultrasound; Scheimpflug; OPTICAL COHERENCE TOMOGRAPHY; THICKNESS MEASUREMENT; INFECTIOUS KERATITIS; INTRALASE FS; REPRODUCIBILITY; ARCHITECTURE; CREATION; ECTASIA;
D O I
10.1097/ICO.0000000000001836
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare direct and indirect LASIK flap thickness measurements using ultrasound and Scheimpflug technology. Methods: Eighty-two eyes treated with laser-assisted in situ keratomileusis refractive surgery using a femtosecond laser (IntraLase FS150) were prospectively included in the study. Flap thickness was set to 115 mu m. Corneal flap thickness was measured using the direct method-ie, ultrasound pachymetry immediately after flap construction in the presence of cavitation bubbles-and indirect methods, with subtraction of intraoperative post-lift corneal thickness measured using ultrasound pachymetry (intrastroma) from preoperative central corneal thickness using ultrasound (Indirect-US) or Scheimpflug thinnest pachymetry (Indirect-Scheimpflug). Results: Mean flap thickness was overestimated using the indirect methods, Indirect-US and Indirect-Scheimpflug (122.6 +/- 24.5 mu m and 128.1 +/- 26.1 mu m, respectively; P < 0.0060 and P < 0.0001, respectively). There were no significant correlations between the direct and indirect methods. Indirect-Scheimpflug was significantly higher (P = 0.0122) than Indirect-US. The closest average flap thickness compared with the set parameter of 115 mu m was that of the direct method (115.6 +/- 8.6 mu m; 95% confidence interval: -1.3 to 2.5; P = 0.5163). The direct method provided the lowest SD of all groups (SD: 8.64). Conclusions: The direct method of flap thickness measurement was the most comparable to the set parameter compared with the indirect subtraction methods. Additional studies are needed to determine which method allows for the most accurate measurement of flap thickness.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 50 条
  • [41] Femtosecond Laser-Assisted In Situ Keratomileusis Treatment of Residual Refractive Error following Femtosecond Laser-Enabled Keratoplasty
    Shen, Elizabeth
    Tsai, Lester
    Castro, Hannah Muniz
    Wade, Matthew
    Farid, Marjan
    JOURNAL OF OPHTHALMOLOGY, 2019, 2019
  • [42] Femtosecond laser-assisted laser in situ keratomileusis versus photorefractive keratectomy: Effect on ocular surface condition
    Sauvageot, Paola
    Julio, Gemma
    Alvarez de Toledo, Juan
    Charoenrook, Victor
    Barraquer, Rafael I.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (02): : 167 - 173
  • [43] Femtosecond Laser-Assisted LASIK Flap Complications
    dos Santos, Allisson Mario
    Torricelli, Andre A. M.
    Marino, Gustavo K.
    Garcia, Renato
    Netto, Marcelo V.
    Bechara, Samir J.
    Wilson, Steven E.
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (01) : 52 - +
  • [44] Effect of repositioning or discarding the epithelial flap in laser-assisted subepithelial keratectomy and epithelial laser in situ keratomileusis
    Taneri, Suphi
    Oehler, Saskia
    Koch, Joerg
    Azar, Dimitri
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (10): : 1832 - 1846
  • [45] Femtosecond-Assisted Laser in situ Keratomileusis with de novo Flap Creation Following Previous Microkeratome Laser in situ Keratomileusis [Response to Letter]
    Rush, Sloan W.
    Rush, Ryan B.
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 2945 - 2946
  • [46] Evaluation of the change in retinal thickness after femtosecond laser-assisted laser in situ keratomileusis and photorefractive keratectomy
    Ozsaygili, Cemal
    Altunel, Orhan
    Duru, Necati
    CURRENT EYE RESEARCH, 2022, 47 (01) : 18 - 24
  • [47] Femtosecond laser flap parameters and visual outcomes in laser in situ keratomileusis
    Issa, Ammar
    Al Hassany, Usama
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (04): : 665 - 674
  • [48] Successful corneal flap replacement following complete traumatic flap amputation after laser-assisted in situ keratomileusis
    Haw, WW
    Manche, EE
    ARCHIVES OF OPHTHALMOLOGY, 2004, 122 (02) : 275 - 276
  • [49] Maculopathies after laser-assisted in situ keratomileusis (LASIK)
    Arevalo, J
    Ruiz-Moreno, JM
    Mendoza, AJ
    Fernandez, CF
    Velez-Vazquez, W
    Rodriguez, FJ
    Rodriguez, A
    Rosales-Meneses, JL
    Dessouki, A
    Chan, CK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U622 - U622
  • [50] Severe diffuse lamellar keratitis after femtosecond laser-assisted in situ keratomileusis: Case report
    Aulanier, A.
    Levy, N.
    Denis, D.
    David, T.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2023, 46 (03): : e95 - e96