Rapid Point-of-Care Assay of Enoxaparin Anticoagulant Efficacy in Whole Blood

被引:0
|
作者
Inchiosa, Mario A. [1 ,2 ]
Pothula, Suryanarayana [2 ]
Kubal, Keshar [1 ,2 ]
Sanchala, Vajubhai T. [2 ]
Navarro, Iris [2 ]
机构
[1] New York Med Coll, Dept Pharmacol, Valhalla, NY 10595 USA
[2] New York Med Coll, Dept Anesthesiol, Valhalla, NY 10595 USA
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2012年 / 68期
关键词
Medicine; Issue; 68; Immunology; Physiology; Pharmacology; low-molecular-weight-heparin; low-molecular-weight-heparin assay; LMWH point-of-care assay; anti-Factor-Xa activity; enoxaparin; heparinase; whole blood; assay;
D O I
10.3791/3852
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
There is the need for a clinical assay to determine the extent to which a patient's blood is effectively anticoagulated by the low-molecularweight-heparin (LMWH), enoxaparin. There are also urgent clinical situations where it would be important if this could be determined rapidly. The present assay is designed to accomplish this. We only assayed human blood samples that were spiked with known concentrations of enoxaparin. The essential feature of the present assay is the quantification of the efficacy of enoxaparin in a patient's blood sample by degrading it to complete inactivity with heparinase. Two blood samples were drawn into Vacutainer tubes (Becton-Dickenson; Franklin Lakes, NJ) that were spiked with enoxaparin; one sample was digested with heparinase for 5 min at 37 degrees C, the other sample represented the patient's baseline anticoagulated status. The percent shortening of clotting time in the heparinase-treated sample, as compared to the baseline state, yielded the anticoagulant contribution of enoxaparin. We used the portable, battery operated Hemochron 801 apparatus for measurements of clotting times (International Technidyne Corp., Edison, NJ). The apparatus has 2 thermostatically controlled (37 degrees C) assay tube wells. We conducted the assays in two types of assay cartridges that are available from the manufacturer of the instrument. One cartridge was modified to increase its sensitivity. We removed the kaolin from the FTK-ACT cartridge by extensive rinsing with distilled water, leaving only the glass surface of the tube, and perhaps the detection magnet, as activators. We called this our minimally activated assay (MAA). The use of a minimally activated assay has been studied by us and others.(2-4) The second cartridge that was studied was an activated partial thromboplastin time (aPTT) assay (A104). This was used as supplied from the manufacturer. The thermostated wells of the instrument were used for both the heparinase digestion and coagulation assays. The assay can be completed within 10 min. The MAA assay showed robust changes in clotting time after heparinase digestion of enoxaparin over a typical clinical concentration range. At 0.2 anti-Xa I.U. of enoxaparin per ml of blood sample, heparinase digestion caused an average decrease of 9.8% (20.4 sec) in clotting time; at 1.0 I.U. per ml of enoxaparin there was a 41.4% decrease (148.8 sec). This report only presents the experimental application of the assay; its value in a clinical setting must still be established.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Rapid analysis of whole blood by paper spray mass spectrometry for point-of-care therapeutic drug monitoring
    Espy, Ryan D.
    Manicke, Nicholas E.
    Ouyang, Zheng
    Cooks, R. Graham
    ANALYST, 2012, 137 (10) : 2344 - 2349
  • [22] A point-of-care microfluidic channel-based device for rapid and direct detection of fibrinogen in whole blood
    Ban, Qinan
    Zhang, Yulong
    Li, Yuxuan
    Cao, Daye
    Ye, Weifeng
    Zhan, Linsheng
    Wang, Daming
    Wang, Xiaohui
    LAB ON A CHIP, 2022, 22 (14) : 2714 - 2725
  • [23] FEASIBILITY STUDY OF A POINT-OF-CARE ASSAY FOR RAPID DETERMINATION OF ANTI-TNFA BIOLOGICS IN CAPILLARY BLOOD
    Reinhard, Christian
    Ricken, Benjamin
    Brosi, Larissa
    Anchling, Leslie
    Neu, Stefan
    Afonso, Joana
    Schuster, Thomas
    Wuthrich, Elina
    Burri, Emanuel
    Paul, Stephane
    Berger, Anne
    Guirao, Wanda
    Barrau, Mathilde
    Bastide, Leaetitia
    Roblin, Xavier
    Pflimlin-Fritschy, Veronique
    Ruscher, Uta
    Hruz, Petr
    Gerhold, Christian B.
    GASTROENTEROLOGY, 2024, 166 (05) : S1100 - S1100
  • [24] Feasibility study of a Point-of-Care assay for rapid determination of anti-TNFα biologics in capillary blood
    Ricken, B.
    Brosi, L.
    Reinhard, C.
    Anchling, L.
    Neu, S.
    Afonso, J.
    Schuster, T.
    Wutherich, E.
    Burri, E.
    Paul, S.
    Berger, A. E.
    Guirao, W.
    Barrau, M.
    Bastide, L.
    Roblin, X.
    Pflimlin-Fritschy, V.
    Rutscher, U.
    Hruz, P.
    Gerhold, C. B.
    JOURNAL OF CROHNS & COLITIS, 2024, 18 : I887 - I887
  • [25] A Rapid Point-of-Care Assay for Cysticercosis Antigen Detection in Urine Samples
    Toribio, Luz
    Handali, Sukwan
    Marin, Yazmin
    Perez, Erika
    Castillo, Yesenia
    Bustos, Javier A.
    O'Neal, Seth E.
    Garcia, Hector H.
    Cysticerco Working Grp Peru
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2023, 108 (03): : 578 - 580
  • [26] Lateral flow assay ruler for quantitative and rapid point-of-care testing
    Li, Zhao
    Chen, Hui
    Wang, Ping
    ANALYST, 2019, 144 (10) : 3314 - 3322
  • [27] Monitoring antiplatelet drug efficacy and resistance with a novel whole blood point-of-care platelet function analyzer
    Anderson, JL
    Ollerton, A
    Watts, M
    Rhodes, J
    Thekkedath, R
    Sukavaneshvar, S
    Mohammad, SF
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2006, 26 (05) : E68 - E69
  • [28] Rapid Optical Heating of Blood for Clinical Point-of-care Diagnostics
    Catanzaro, Brian E.
    Hill, Ted
    Hankins, Steve
    Gandola, Kent
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS VIII, 2010, 7555
  • [29] Exploring the utility of a novel point-of-care whole blood thrombin generation assay following trauma: A pilot study
    Ferrara, Michael J.
    MacArthur, Taleen A.
    Butenas, Saulius
    Mann, Kenneth G.
    Immermann, Joseph M.
    Spears, Grant M.
    Bailey, Kent R.
    Kozar, Rosemary A.
    Heller, Stephanie F.
    Loomis, Erica A.
    Stephens, Daniel
    Park, Myung S.
    RESEARCH AND PRACTICE IN THROMBOSIS AND HAEMOSTASIS, 2021, 5 (03) : 395 - 402
  • [30] Photoacoustic lateral flow assay for point-of-care testing of thrombin in human whole blood without background interference
    Guo, Lan
    Zhao, Dong-Mei
    Chen, Shuai
    Yu, Yong-Liang
    MICROCHEMICAL JOURNAL, 2025, 208