A glass/PDMS electrophoresis microchip embedded with molecular imprinting SPE monolith for contactless conductivity detection

被引:29
|
作者
Zhai, Haiyun [1 ]
Li, Jiangmei [1 ]
Chen, Zuanguang [2 ]
Su, Zihao [1 ]
Liu, Zhenping [1 ]
Yu, Xiao [1 ]
机构
[1] Guangdong Pharmaceut Univ, Coll Pharm, Guangzhou 510006, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Sch Pharmaceut Sci, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Microchip; Capillary electrophoresis; Contactless conductivity detection; Molecularly imprinted solid-phase extraction; Auramine O; SOLID-PHASE EXTRACTION; INTEGRATED MICROFLUIDIC DEVICE; IONIZATION MASS-SPECTROMETRY; CAPILLARY-ELECTROPHORESIS; LIQUID-CHROMATOGRAPHY; DEGRADATION-PRODUCTS; BASIC DRUGS; CHIP; POLYMERS; PRECONCENTRATION;
D O I
10.1016/j.microc.2014.01.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple glass/PDMS microfluidic chip for on-line sample pretreatment and contactless conductivity detection, which consisted of a 0.17 mm-thick glass cover and a PDMS substrate embedded with an SPE monolithic column, was presented in this paper. Using this integrated microchip system, sample extraction, injection, separation and detection were automatically performed in sequence. A sample of auramine O was concentrated by molecularly imprinted SPE (MISPE), eluted to sample reservoir, and injected by electromigration into separation channel for electrophoresis separation and contactless conductivity detection, with the calculated detection limit (S/N = 3) being 2.5 mu g mL(-1). The monolithic column was utilized to quantitatively extract auramine 0, yielding an on-line enrichment factor of about 12. The microchip system is reliable and applicable to the analysis of auramine Din food sample. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:223 / 228
页数:6
相关论文
共 50 条
  • [31] Contactless conductivity detection for capillary electrophoresis
    Zemann, AJ
    Mayrhofer, K
    Schnell, E
    Bonn, GK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U162 - U162
  • [32] Contactless conductivity detector integrated in silicon-based electrophoresis microchip
    Gu, Wen-Wen
    Wen, Zhi-Yu
    Wen, Zhong-Quan
    Xu, Yi
    Liang, Feng-Fei
    Liu, Hai-Tao
    Nami Jishu yu Jingmi Gongcheng/Nanotechnology and Precision Engineering, 2010, 8 (04): : 362 - 367
  • [33] Screen-Printed Contactless Conductivity Detector for Microchip Capillary Electrophoresis
    Wang, Joseph
    Chen, Gang
    Chatrathi, Madhu Prakash
    Wang, Mei
    Rinehart, Robert
    Muck, Alexander
    ELECTROANALYSIS, 2008, 20 (22) : 2416 - 2421
  • [34] A simple poly(dimethylsiloxane) electrophoresis microchip with an integrated contactless conductivity detector
    Liu, Benyan
    Jin, Qinghui
    Zhang, Yi
    Mayer, Dirk
    Krause, Hans-Joachim
    Zhao, Jianlong
    Offenhaeusser, Andreas
    MICROCHIMICA ACTA, 2011, 172 (1-2) : 193 - 198
  • [35] Quantification of lactate in synovia by microchip with contactless conductivity detection
    Song, Zhirui
    Xu, Yue
    Chen, Zuanguang
    Yang, Jianping
    Li, Xinchun
    Zhang, Zhiguang
    ANALYTICAL BIOCHEMISTRY, 2013, 434 (01) : 73 - 77
  • [36] Amperometric PDMS/glass capillary electrophoresis-based biosensor microchip for catechol and dopamine detection
    Schöning, MJ
    Jacobs, M
    Muck, A
    Knobbe, DT
    Wang, J
    Chatrathi, M
    Spillmann, S
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2): : 688 - 694
  • [37] A simple poly(dimethylsiloxane) electrophoresis microchip with an integrated contactless conductivity detector
    Benyan Liu
    Qinghui Jin
    Yi Zhang
    Dirk Mayer
    Hans-Joachim Krause
    Jianlong Zhao
    Andreas Offenhäusser
    Microchimica Acta, 2011, 172 : 193 - 198
  • [38] Determination of vitamin C and preservatives in beverages by conventional capillary electrophoresis and microchip electrophoresis with capacitively coupled contactless conductivity detection
    Law, WS
    Kubán, P
    Zha, JH
    Li, SFY
    Hauser, PC
    ELECTROPHORESIS, 2005, 26 (24) : 4648 - 4655
  • [39] Poly(dimethylsiloxane) microchip electrophoresis with contactless conductivity detection for measurement of chemical warfare agent degradation products
    Ding, Yongsheng
    Garcia, Carlos D.
    Rogers, Kim R.
    ANALYTICAL LETTERS, 2008, 41 (02) : 335 - 350
  • [40] Determination of anti-oxidative histidine dipeptides in poultry by microchip capillary electrophoresis with contactless conductivity detection
    Jozanovic, Marija
    Hajdukovic, Mateja
    Galovic, Olivera
    Kralik, Gordana
    Kralik, Zlata
    Sakac, Nikola
    Medvidovic-Kosanovic, Martina
    Sak-Bosnar, Milan
    FOOD CHEMISTRY, 2017, 221 : 1658 - 1665