Measurement and calculation of heterogeneity correction factors for an Ir-192 high dose-rate brachytherapy source behind tungsten alloy and steel shields

被引:27
|
作者
Kirov, AS
Williamson, JF
Meigooni, AS
Zhu, Y
机构
[1] Radiation Oncology Center, Mallinckrodt Institute of Radiology, Washington Univ. School of Medicine, St. Louis
关键词
heterogeneity corrections; Ir-192; HDR; TLD; Monte Carlo; detector artifacts;
D O I
10.1118/1.597733
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Shields made of high atomic number material are commonly used in vaginal applicators with high dose-rate (HDR) (192)IR remotely afterloaded brachytherapy sources. However little data is available for the dose distribution around such shields. Heterogeneity correction factors (HCFs) are defined as the ratio of the dose to a point with the heterogeneity (shield) in place, divided by the dose to the same point with no heterogeneity. Using thermoluminescent dosimeters (TLDs) in solid water phantom we have measured the HCFs behind 6 and 20 mm diam tungsten alloy disks, 4 and 2 mm thick and a 4 mm thick steel disk, positioned 15 mm from the source. For each measurement point, the heterogeneity correction factors were also inferred from Monte Carlo simulations, which accurately modeled the experimental geometry. The agreement between measured and calculated HCFs on the average was within 6%. Tungsten alloy disks resulted in about two times greater dose reduction in water (HCF approximate to 0.4, for 20X4 mm disk) than for a steel disk with the same dimensions (HCF approximate to 0.85). Reducing the disk diameter to 6 mm increased the dose transmission up to about 25%. Increasing the source-to-detector distance from 4 to 7 cm caused a change in HCF from 2% to more than 20%, depending on disk material and diameter. The detector artifact effects arising from the finite size and different composition of the TLD chips were determined. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:911 / 919
页数:9
相关论文
共 50 条
  • [1] EVALUATION OF THE BUILDUP EFFECT OF AN IR-192 HIGH DOSE-RATE BRACHYTHERAPY SOURCE
    PARK, HC
    ALMOND, PR
    MEDICAL PHYSICS, 1992, 19 (05) : 1293 - 1297
  • [2] TLD, diode and monte carlo dosimetry of an Ir-192 source for high dose-rate brachytherapy
    Kirov, AS
    Williamson, JF
    Meigooni, AS
    Zhu, Y
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (12): : 2015 - 2036
  • [3] Absorbed Dose to Water Measurement with a Sandwich Method for High Dose-Rate Ir-192 Brachytherapy Sources
    Araki, F.
    Yoshiyama, F.
    Ohno, T.
    Kakei, K.
    Wulff, J.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [4] Transit dose of an Ir-192 high dose rate brachytherapy stepping source
    Wong, TPY
    Fernando, W
    Johnston, PN
    Bubb, IF
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02): : 323 - 331
  • [5] Radiochromic film measurement of anisotropy function for high-dose-rate Ir-192 brachytherapy source
    Sharma, SD
    Bianchi, C
    Conte, L
    Novario, R
    Bhatt, BC
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (17): : 4065 - 4072
  • [6] DOSE-RATE INTRALUMINAL BRACHYTHERAPY FOR TREATMENT OF ESOPHAGEAL CANCER WITH IR-192 WIRES
    CASPERS, RJL
    DAVELAAR, J
    SEWSINGH, EN
    GRIFFIOEN, G
    LEER, JWH
    BRACHYTHERAPY 2, 1989, : 445 - 448
  • [7] Impact of different Ir-192 source models on dose calculations in high-dose-rate brachytherapy
    Otani, Yuki
    Shimamoto, Shigetoshi
    Sumida, Iori
    Takahashi, Yutaka
    Tani, Shoji
    Oshima, Tetsuya
    Onosaka, Satoshi
    Isohashi, Fumiaki
    Tamari, Keisuke
    Ogawa, Kazuhiko
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2018, 7 : 23 - 26
  • [8] Optimization of deterministic transport parameters for the calculation of the dose distribution around a high dose-rate 192Ir brachytherapy source
    Gifford, Kent A.
    Price, Michael J.
    Horton, John L., Jr.
    Wareing, Todd A.
    Mourtada, Firas
    MEDICAL PHYSICS, 2008, 35 (06) : 2279 - 2285
  • [9] Comparative dosimetry of GammaMed Plus high-dose rate Ir-192 brachytherapy source
    Patel, N. P.
    Majumdar, B.
    Vijayan, V.
    JOURNAL OF MEDICAL PHYSICS, 2010, 35 (03) : 137 - 143
  • [10] Calibration of Ir-192 high dose rate brachytherapy source using different calibration procedures
    Bondel, Shwetha
    Ravikumar, Manickham
    Supe, Sanjay Sudhakar
    Reddy, Buchuppudi Rekha
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2014, 19 (03) : 151 - 156