Towards disposable lab-on-a-chip:: Poly(methylmethacrylate) microchip electrophoresis device with electrochemical detection

被引:0
|
作者
Wang, J [1 ]
Pumera, M
Chatrathi, MP
Escarpa, A
Konrad, R
Griebel, A
Dörner, W
Löwe, H
机构
[1] New Mexico State Univ, Dept Chem & Biochem, Las Cruces, NM 88003 USA
[2] Mainz GmbH, Inst Mikrotech, Mainz, Germany
关键词
electrochemical detection; hydrazines; microchip electrophoresis; phenols; poly(methylmethacrylate);
D O I
10.1002/1522-2683(200202)23:4<596::AID-ELPS596>3.0.CO;2-C
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fully disposable microanalytical device based on combination of poly(methylmethacrylate) (PMMA) capillary electrophoresis microchips and thick-film electrochemical detector strips is described. Variables influencing the separation efficiency and amperometric response, including separation voltage or detection potential are assessed and optimized. The versatility, simplicity and low-cost advantages of the new design are coupled to an attractive analytical performance, with good precision (relative standard deviation RSD = 1.68% for n = 10). Applicability for assays of mixtures of hydrazine, phenolic compounds, and catecholamines is demonstrated. Such coupling of low-cost PMMA-based microchips with thick-film electrochemical detectors holds great promise for mass production of single-use micrototal analytical systems.
引用
收藏
页码:596 / 601
页数:6
相关论文
共 50 条
  • [31] Towards lab-on-a-chip diagnostics for malaria elimination
    Kolluri, N.
    Klapperich, C. M.
    Cabodi, M.
    LAB ON A CHIP, 2018, 18 (01) : 75 - 94
  • [32] Injection, separation and fluorimetric detection of DNA in glass lab-on-a-chip for capillary gel electrophoresis
    Kubicki, Wojciech
    Walczak, Rafal
    Dziuban, Jan
    OPTICA APPLICATA, 2011, 41 (02) : 409 - 416
  • [33] A prefilled, ready-to-use electrophoresis based lab-on-a-chip device for monitoring lithium in blood
    Floris, Arjan
    Staal, Steven
    Lenk, Stefan
    Staijen, Erik
    Kohlheyer, Dietrich
    Eijkel, Jan
    van den Berg, Albert
    LAB ON A CHIP, 2010, 10 (14) : 1799 - 1806
  • [34] Lab-on-a-Chip based device for an optical detection of immobilized cells for food analytics
    Sauter, F.
    Klemm, R.
    Gaertner, C.
    Miethe, P.
    Henze, S.
    Brueckner, P.
    Fuetterer, R.
    Becker, H.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57
  • [35] Lab-on-a-Chip devices with electrochemical detection for field monitoring of organic and ionic explosives
    Wang, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U341 - U341
  • [36] From chip-in-a-lab to lab-on-a-chip: towards a single handheld electronic system for multiple application-specific lab-on-a-chip (ASLOC)
    Neuzil, P.
    Campos, C. D. M.
    Wong, C. C.
    Soon, J. B. W.
    Reboud, J.
    Manz, A.
    LAB ON A CHIP, 2014, 14 (13) : 2168 - 2176
  • [37] Disposable thermo-pneumatic micropurnp for bio lab-on-a-chip application
    Ha, Seung-Mo
    Cho, Woong
    Ahn, Yoomin
    MICROELECTRONIC ENGINEERING, 2009, 86 (4-6) : 1337 - 1339
  • [38] Lab-on-a-chip device for food quality control and safety
    Rafiq, Syed Mansha
    Majumder, Reshab
    Joshi, Deepak
    Dar, Aamir Hussain
    Dash, Kshirod Kumar
    Pandey, Vinay Kumar
    Sidiqi, Urba Shafi
    FOOD CONTROL, 2024, 164
  • [39] Integrated electrochemical DNA biosensors for lab-on-a-chip devices
    Mir, Monica
    Homs, Antoni
    Samitier, Josep
    ELECTROPHORESIS, 2009, 30 (19) : 3386 - 3397
  • [40] Development of a lab-on-a-chip device for diagnosis of plant pathogens
    Julich, Sandra
    Riedel, Marko
    Kielpinski, Mark
    Urban, Matthias
    Kretschmer, Robert
    Wagner, Stefan
    Fritzsche, Wolfgang
    Henkel, Thomas
    Moeller, Robert
    Werres, Sabine
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (10): : 4070 - 4075