Experimental study on damping characteristics of the tuned liquid column damper with magnetic fluid

被引:10
|
作者
Masuda, H. [1 ]
Oyamada, T. [1 ]
Sawada, T. [1 ]
机构
[1] Keio Univ, Dept Mech Engn, Kohoku Ku, Yokohama, Kanagawa 2238522, Japan
关键词
BUILDINGS;
D O I
10.1088/1742-6596/412/1/012049
中图分类号
O59 [应用物理学];
学科分类号
摘要
A magnetic fluid is a smart, colloidal, and strongly magnetizable fluid, and is composed of a base liquid, ferromagnetic particles, and a chemically adsorbed surfactant. A tuned liquid column damper (TLCD) - devised for vibration mitigation of high structures-is a passive damper categorized as a dynamic absorber. Using a magnetic fluid as the working fluid of a TLCD can improve and change the TLCD into a novel semiactive damper. The natural frequency of a TLCD with a magnetic fluid can be changed via a magnetic field. This novel damper can be used as an effective vibration suppression mechanism for building structures. In this study, we investigate the effect of the magnetic field on the natural frequency of a TLCD with a magnetic fluid. In addition, using the experimental results, we demonstrate the relationship between the setting positions of an electromagnet, the strength of the magnetic field, and the changes in the natural frequency.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Feasibility Study of Tuned Liquid Column Damper for Ocean Wave Energy Extraction
    Wong, Yihong
    King, Yeong-Jin
    Lai, An-Chow
    Chong, Kok-Keong
    Lim, Boon-Han
    GREEN AND SUSTAINABLE TECHNOLOGY, 2017, 1828
  • [32] STUDY OF OFFSHORE JACKET PLATFORM ATTACHED WITH TUNED LIQUID COLUMN GAS DAMPER
    Sathish, P.
    Sajith, A. S.
    PROCEEDINGS OF THE ASME 36TH INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, 2017, VOL 1, 2017,
  • [33] Semiactive tuned liquid column dampers: Experimental study
    Yalla, SK
    Kareem, A
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2003, 129 (07): : 960 - 971
  • [34] Comparative study of utilizing a new type V-Shaped Tuned Liquid Column Damper and U-Shaped Tuned Liquid Column Damper in floating wind turbines
    Shadman, Milad
    Akbarpour, Abbas
    PROCEEDINGS OF THE ASME 31ST INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARTIC ENGINEERING, VOL 7, 2013, : 277 - 283
  • [35] Experimental Study on Using Uniform Tuned Liquid Column Damper for Structural Control of Buildings Resting on Loose Soil
    Sarlak, A.
    Saeedmonir, H.
    Gheyratmand, C.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2018, 31 (07): : 1028 - 1037
  • [36] Response of an Annular Tuned Liquid Damper Equipped With Damping Screens
    McNamara, K. P.
    Love, J. S.
    Tait, M. J.
    Haskett, T. C.
    JOURNAL OF VIBRATION AND ACOUSTICS-TRANSACTIONS OF THE ASME, 2021, 143 (01):
  • [37] Experimental evaluation of a tuned liquid damper system
    Ju, YK
    Yoon, SW
    Kim, SD
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2004, 157 (04) : 251 - 262
  • [38] Theoretical and experimental study on vibration control of a tuned liquid inerter damper with additional damping net and sloped-bottom
    Sun, Hao-ding
    He, Hao-xiang
    Cheng, Yang
    Gao, Xiao-jian
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2024, 213
  • [39] Earthquake mitigation in building construction by tuned liquid column damper
    Ziegler, F.
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2005, 122 (05): : 164 - 168
  • [40] Vibration Control of Structures by an Upgraded Tuned Liquid Column Damper
    Quoc Huong Cao