Comparison of dynamic changes in aortic diameter during the cardiac cycle measured by computed tomography angiography and transthoracic echocardiography

被引:11
|
作者
Huang, Jian [1 ,2 ]
Wang, Yongsheng [1 ]
Lin, Lin [3 ]
Li, Zhibin [4 ]
Shan, Zhonggui [2 ]
Zheng, Shaoyi [1 ]
机构
[1] Southern Med Univ, Nanfang Hosp, Dept Cardiovasc Surg, Sch Clin Med 1, 1023 S Shatai Rd, Guangzhou 510515, Guangdong, Peoples R China
[2] Xiamen Univ, Affiliated Hosp 1, Dept Cardiovasc Surg, Xiamen, Peoples R China
[3] Xiamen Univ, Affiliated Hosp 1, Cent Lab, Xiamen, Peoples R China
[4] Xiamen Univ, Affiliated Hosp 1, Epidemiol Res Unit, Xiamen, Peoples R China
关键词
Aortic diameter; Transthoracic echocardiography; Computed tomography angiography; Intraoperative ultrasound; Dynamic change; ASSOCIATION; DISSECTION; SOCIETY; IMPACT;
D O I
10.1016/j.jvs.2018.07.083
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study aimed to examine the relationship between dynamic changes in aortic diameter and corresponding measurement methods. Methods: Consecutive adult (nonaneurysmal) patients being surgically treated for heart disease (mean age, 51 +/- 11 years; range, 29-76 years; N = 25) were included in this study. All patients underwent transthoracic echocardiography (TTE), computed tomography angiography (CTA), and intraoperative ultrasound (IOUS). Anteroposterior diameters were measured at 1 cm above the junction of the aortic sinus, the proximal 1 cm of the innominate artery, and the midpoint of the two. Results: The average diameter of the proximal ascending aorta in systole/diastole measured by IOUS was 32.07 +/- 2.03/30.27 +/- 2.05 mm (paired t-test: difference, 1.80 +/- 0.46 mm; P < .001). The average diameters of the proximal ascending aorta measured by nonelectrocardiography-gated CTA and TTE were 31.45 +/- 1.97 mm and 29.7 +/- 1.84 mm, respectively. The average diameter of the mid and distal ascending aorta in systole/diastole measured by IOUS was 32.35 +/- 1.95/30.57 +/- 1.94 mm (paired t-test: difference, 1.78 +/- 0.44 mm; P < .001) and 32.32 +/- 1.92/30.67 +/- 1.90 mm (paired t-test: difference, 1.65 +/- 0.42 mm; P < .001), respectively. The average diameter of themid and distal ascending aorta measured by CTA was 31.74 +/- 1.92 mm and 31.59 +/- 1.96 mm, respectively. At each location, the difference in the aortic diameter between systole and diastole was statistically significant (all P values < .001; paired t-test). The minimum and maximum changes in the diameter between systole and diastole were 0.90 mm and 2.70 mm. In all, 96% (24/25) of the average diameters derived from IOUS and CTA at the three locations were within the concordance limit in systole, and 92% to 100% (23/25 to 25/25) were within the concordance limit in diastole. The average diameters derived from IOUS and TTE images of the proximal ascending aorta were within the bounds of the concordance limit 92% (23/25) of the time in systole and 100% (25/25) of the time in diastole. The average diameters derived from CTA and TTE images of the proximal ascending aorta were within the bounds of the concordance limit 88%(22/25) of the time. Pearson correlation coefficients between these groups ranged from 0.905 to 0.982 (all P values < . 01). Conclusions: The ascending aorta diameters measured by nonelectrocardiography-gated CTA and TTE were consistent with the IOUS measurements.
引用
收藏
页码:1538 / 1544
页数:7
相关论文
共 50 条
  • [31] Quadricuspid Aortic Valve Defined by Echocardiography and Cardiac Computed Tomography
    Karlsberg, Daniel W.
    Elad, Yaron
    Kass, Robert M.
    Karlsberg, Ronald P.
    CLINICAL MEDICINE INSIGHTS-CARDIOLOGY, 2012, 6 : 41 - 44
  • [32] The Role of Computed Tomography Coronary Angiography in Kawasaki Disease: Comparison with Transthoracic Echocardiography in a 25-Case Retrospective Study
    Jrad, Myriam
    Ben Salem, Fares
    Barhoumi, Chaima
    Lassoued, Firas
    Frikha, Wassim
    Boukriba, Seif
    Mizouni, Habiba
    PEDIATRIC CARDIOLOGY, 2019, 40 (02) : 265 - 275
  • [33] Comparison of Computed Tomography Angiography to Trans-Esophageal Echocardiography for Evaluation of Aortic Arch Atheroma Calcification
    Barazangi, Nobl
    Wintermark, Max
    Lease, Katy
    Rao, Rajni
    Smith, Wade
    Josephson, S. A.
    STROKE, 2009, 40 (04) : E199 - E199
  • [34] Double aortic arch - Suspected upon transthoracic echocardiography and diagnosed upon computed tomography
    Koz, Cem
    Yokusoglu, Mehmet
    Uzun, Mehmet
    Tasar, Mustafa
    TEXAS HEART INSTITUTE JOURNAL, 2008, 35 (01) : 80 - 81
  • [35] Quantification of Aortic Valve Stenosis Head-to-Head Comparison of 64-Slice Spiral Computed Tomography With Transesophageal and Transthoracic Echocardiography and Cardiac Catheterization
    Lembcke, Alexander
    Kivelitz, Dietmar E.
    Borges, Adrian C.
    Lachnitt, Andre
    Hein, Patrick A.
    Dohmen, Pascal M.
    Thiele, Holger
    INVESTIGATIVE RADIOLOGY, 2009, 44 (01) : 7 - 14
  • [36] Agreement between transthoracic echocardiography and computed tomography pulmonary angiography for detection of right ventricular failure
    Erol, Serhat
    Ayoz, Sumeyye
    Kaya, Aslihan Gurun
    Ciftci, Fatma
    Ciledag, Aydin
    Onen, Zeynep Pinar
    Kaya, Akin
    Kumbasar, Ozlem Ozdemir
    Gursoy, Aysegul
    Kul, Melahat
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [37] Evaluation of Electrocardiogram-Gated Computed Tomography Angiography to Quantify Changes in Geometry and Dynamic Behavior during the Cardiac Cycle of the Nellix Endovascular Sealing System
    van den Ham, Leo H.
    Lazarian, Talar
    Jebbink, Erik Groot
    Lardenoije, Jan-Willem
    Zeebregts, Clark J.
    Reijnen, Michel M. P. J.
    RADIOLOGY RESEARCH AND PRACTICE, 2023, 2023
  • [38] COMPARISON OF AORTIC VALVE AREA ON COMPUTED TOMOGRAPHY VERSUS ECHOCARDIOGRAPHY
    Foley, R.
    Lyen, S.
    Manghat, N.
    Hamilton, M.
    HEART, 2020, 106 : A3 - A4
  • [39] Algorithm Comparison for Cardiac Image Fusion of Coronary Computed Tomography Angiography and 3D Echocardiography
    Nordenfur, Tim
    Babic, Aleksandar
    Bulatovic, Ivana
    Giesecke, Anders
    Gunyeli, Elif
    Ripsweden, Jonaz
    Samset, Eigil
    Winter, Reidar
    Larsson, Matilda
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [40] Method comparison for cardiac image registration of coronary computed tomography angiography and 3-D echocardiography
    Nordenfur, Tim
    Babic, Aleksandar
    Bulatovic, Ivana
    Giesecke, Anders
    Gunyeli, Elif
    Ripsweden, Jonaz
    Samset, Eigil
    Winter, Reidar
    Larsson, Matilda
    JOURNAL OF MEDICAL IMAGING, 2018, 5 (01)