Silver nanowires immobilized on gold-modified glassy carbon electrode for electrochemical quantification of atorvastatin

被引:12
|
作者
Naseri, Amene [1 ,2 ]
Hormozi-Nezhad, Mohammad Reza [1 ]
Shahrokhian, Saeed [1 ,3 ]
Asadian, Elham [4 ]
机构
[1] Sharif Univ Technol, Dept Chem, Tehran 111553516, Iran
[2] Sharif Univ Technol, Dept Phys, Tehran 111559161, Iran
[3] Sharif Univ Technol, Inst Nanosci & Nanotechnol, Tehran 145888969, Iran
[4] Shahid Beheshti Univ Med Sci, Sch Med, Dept Med Phys & Biomed Engn, Tehran, Iran
关键词
Silver nanowires; Gold modified electrode; Differential pulse voltammetry; Atorvastatin; Pharmaceutical and clinical analysis; VOLTAMMETRIC DETERMINATION; METAL NANOSTRUCTURES; NANOPARTICLES; NANOTUBES; SENSOR; OXIDATION; BEHAVIOR; CALCIUM; FILM;
D O I
10.1016/j.jelechem.2020.114540
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Development of simple yet precise sensing platforms for rapid determination of biological species and drugs is of paramount importance, not only for analysis of pharmaceutical formulations during the production stage, but also in clinical practices and medical diagnosis. In the present research, we report on the electrochemical determination of atorvastatin (ATOR) by using silver nanowires/gold-modified glassy carbon electrode (AgNWs/Au/GCE). The modified electrode was constructed through a two-step procedure in which narrow silver nanowires synthesized via a polyol method are drop casted on a pre-modified GCE with electrodeposited gold particles. The results of XRD analysis indicated the purity of the crystal structure of Ag nanowires. The electrochemical response characteristics of ATOR are investigated by means of cyclic and differential pulse voltammetric techniques (CV and DPV) on the surface of the modified electrode. Moreover, the effect of various experimental parameters including pH, accumulation time and the modifier volume on the differential pulse voltammetric responses of ATOR is evaluated. The results revealed that under the optimal conditions, there is a remarkable enhancement in the peak current of ATOR associated with a noticeable decrease in its peak potential. The obtained wide dynamic linear range (10-100 nM) with a detection limit as low as 1 nM along with the ability of the modified electrode to successfully determine ATOR in pharmaceutical and human plasma samples turned it to a useful sensing platform for sensitive determination of ATOR in practical applications.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Electrochemical detection of mercury ions using glassy carbon electrode modified with silver sulphide nanoparticles
    Rani, R. Helen
    Rahale, C. Sharmila
    Girija, S.
    Wilson, J.
    Prasanthrajan, M.
    Sharmila, D. Jeyasundara
    Saranya, N.
    Maragatham, S.
    PHYSICA SCRIPTA, 2024, 99 (10)
  • [22] Electrochemical Impedance of Oxygen Reduction in Acidic Solution at Silver-Modified Glassy Carbon Electrode
    Kazeman, Isa
    Hasanzadeh, Mohammad
    Jafarian, Majid
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (05): : 447 - 456
  • [23] Electrochemical co-detection of Arsenic and Selenium on a Glassy Carbon Electrode Modified with Gold Nanoparticles
    Idris, A. O.
    Mabuba, N.
    Arotiba, O. A.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (01): : 10 - 21
  • [24] Electrochemical Determination of Tyrosine Using Graphene and Gold Nanoparticle Composite Modified Glassy Carbon Electrode
    Liu, M.
    Lao, J.
    Wang, H.
    Xu, Z.
    Li, J.
    Wen, L.
    Yin, Z.
    Luo, C.
    Peng, H.
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2021, 57 (01) : 41 - 50
  • [25] The electrochemical reaction mechanism of selenocystine on selenium-gold film modified glassy carbon electrode
    Bai, Yan
    Yan, Xiaoli
    Zheng, Wenjie
    Li, Rui
    Cheng, Tao
    Ruan, Xiangyuan
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2006, 49 (02) : 112 - 116
  • [26] Electrochemical Determination of Tyrosine Using Graphene and Gold Nanoparticle Composite Modified Glassy Carbon Electrode
    M. Liu
    J. Lao
    H. Wang
    Z. Xu
    J. Li
    L. Wen
    Z. Yin
    C. Luo
    H. Peng
    Russian Journal of Electrochemistry, 2021, 57 : 41 - 50
  • [27] Electrochemical simultaneous determination of nitrophenol isomers at nano-gold modified glassy carbon electrode
    Chu, Lin
    Han, Lu
    Zhang, Xiaoli
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2011, 41 (06) : 687 - 694
  • [28] Electrochemical determination of arsenite using a gold nanoparticle modified glassy carbon electrode and flow analysis
    Majid, E
    Hrapovic, S
    Liu, YL
    Male, KB
    Luong, JHT
    ANALYTICAL CHEMISTRY, 2006, 78 (03) : 762 - 769
  • [29] Electrochemical simultaneous determination of nitrophenol isomers at nano-gold modified glassy carbon electrode
    Lin Chu
    Lu Han
    Xiaoli Zhang
    Journal of Applied Electrochemistry, 2011, 41 : 687 - 694
  • [30] Electrochemical Determination of Furosemide Drug at Tranexamic Acid Gold Nanoparticles Modified Glassy Carbon Electrode
    Chandio, Tasawar Ali
    Yalcinkaya, Ozcan
    Khan, M. Nasiruddin
    Kayis, Elif Calik
    Hassan, Atya
    Kayis, Ahmet Furkan
    PAKISTAN JOURNAL OF ANALYTICAL & ENVIRONMENTAL CHEMISTRY, 2021, 22 (01) : 172 - 179