Shock Tube Measurement of Ethylene Ignition Delay Time and Molecular Collision Theory Analysis

被引:0
|
作者
Xiong, Xiao-he [1 ]
Ding, Yan-jun [1 ]
Shi, Shuo [1 ]
Peng, Zhi-min [1 ]
机构
[1] Tsinghua Univ, Dept Thermal Engn, State Key Lab Power Syst, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Shock tube; Ethylene; Ignition delay; Molecule collision; MIXTURES; KINETICS; OXYGEN; TEMPERATURES; OXIDATION; HYDROGEN; FUELS; ARGON;
D O I
10.1063/1674-0068/29/cjcp1605104
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
In this study, 75% and 96% argon diluent conditions were selected to determine the ignition delay time of stoichiometric mixture of C2H4/O-2/Ar within a range of pressures (1.3-3.0 atm) and temperatures (1092-1743 K). Results showed a logarithmic linear relationship of the ignition delay time with the reciprocal of temperatures. Under both two diluent conditions, ignition delay time decreased with increased temperature. By multiple linear regression analysis, the ignition delay correlation was deduced. According to this correlation, the calculated ignition delay time in 96% diluent was found to be nearly five times that in 75% diluent. To explain this discrepancy, the hard-sphere collision theory was adopted, and the collision numbers of ethylene to oxygen were calculated. The total collision numbers of ethylene to oxygen were 5.99 x 10(30) s(-1) cm(-3) in 75% diluent and 1.53x10(29) s(-1) cm(-3) in 96% diluent (about 40 times that in 75% diluent). According to the discrepancy between ignition delay time and collision numbers, viz. 5 times corresponds to 40 times, the steric factor can be estimated.
引用
收藏
页码:761 / 766
页数:6
相关论文
共 50 条
  • [21] Shock tube study of kerosene ignition delay at high pressures
    LIANG JinHu 1
    2 State Key Laboratory of High Temperature Gas Dynamics
    Science China(Physics,Mechanics & Astronomy), 2012, (06) : 947 - 954
  • [22] Shock tube study of kerosene ignition delay at high pressures
    Liang JinHu
    Wang Su
    Hu HongHao
    Zhang ShengTao
    Fan BingCheng
    Cui JiPing
    SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY, 2012, 55 (06) : 947 - 954
  • [23] Shock tube measurements of branched alkane ignition delay times
    Li, Sijie
    Campos, Ashley
    Davidson, David F.
    Hanson, Ronald K.
    FUEL, 2014, 118 : 398 - 405
  • [24] Shock tube study of kerosene ignition delay at high pressures
    JinHu Liang
    Su Wang
    HongHao Hu
    ShengTao Zhang
    BingCheng Fan
    JiPing Cui
    Science China Physics, Mechanics and Astronomy, 2012, 55 : 947 - 954
  • [25] Shock tube measurements of ignition delay times for the butanol isomers
    Stranic, Ivo
    Chase, Deanna P.
    Harmon, Joseph T.
    Yang, Sheng
    Davidson, David F.
    Hanson, Ronald K.
    COMBUSTION AND FLAME, 2012, 159 (02) : 516 - 527
  • [26] Experimental study of measuring the ignition delay time of toluene and n-decane by a shock tube
    State Key Laboratory of Laser Propulsion and Application, Academy of Equipment, Beijing
    101416, China
    Hanneng Cailiao, 10 (971-976):
  • [27] Experimental studies of the adsorption in shock tube measurements of the JP-10 ignition delay time
    College of Chemistry and Chemical Engineering, Chongqing University, Chongqing 400044, China
    不详
    Shiyan Liuti Lixue, 2006, 4 (69-72):
  • [28] Heat Flux Measurement in Shock Heated Combustible Gases and Clarification of Ignition Delay Time
    Kotov, Mikhail A.
    Kozlov, Pavel, V
    Gerasimov, Gennady Ya
    Levashov, Vladimir Yu
    Shemyakin, Andrey N.
    Solovyov, Nikolay G.
    Yakimov, Mikhail Yu
    Glebov, Vladislav N.
    Dubrova, Galina A.
    Malyutin, Andrey M.
    FLUIDS, 2022, 7 (09)
  • [29] Non-uniform ignition behind a reflected shock and its influence on ignition delay measured in a shock tube
    C. Huang
    C. Qi
    Z. Chen
    Shock Waves, 2019, 29 : 957 - 967
  • [30] Non-uniform ignition behind a reflected shock and its influence on ignition delay measured in a shock tube
    Huang, C.
    Qi, C.
    Chen, Z.
    SHOCK WAVES, 2019, 29 (07) : 957 - 967