Functional magnetic resonance imaging (fMRI) is a widely used technique for generating images or maps of human brain activity. The applications of the technique are widespread in cognitive neuroscience and it is hoped they will eventually extend into clinical practice. The activation signal measured with fMRI is predicated on indirectly measuring changes in the concentration of deoxyhaemoglobin which arise from an increase in blood oxygenation in the vicinity of neuronal firing. The exact mechanisms of this blood oxygenation level dependent (BOLD) contrast are highly complex. The signal measured is dependent on both the underlying physiological events and the imaging physics. BOLD contrast, although sensitive, is not a quantifiable measure of neuronal activity A number of different imaging techniques and parameters can be used for fMRI, the choice of which depends on the particular requirements of each functional imaging experiment. The high-speed MRI technique, echo-planar imaging provides the basis for most fMRI experiments. The problems inherent to this method and the ways in which these may be overcome are particularly important in the move towards performing functional studies on higher field MRI systems. Future developments in techniques and hardware are also likely to enhance the measurement of brain activity using MRI.
引用
收藏
页码:1179 / 1194
页数:16
相关论文
共 50 条
  • [41] Functional polymers as metal-free magnetic resonance imaging contrast agents
    Fu, Changkui
    Yu, Ye
    Xu, Xin
    Wang, Qiaoyun
    Chang, Yixin
    Zhang, Cheng
    Zhao, Jiacheng
    Peng, Hui
    Whittaker, Andrew K.
    PROGRESS IN POLYMER SCIENCE, 2020, 108
  • [42] A pH-sensitive contrast agent for functional magnetic resonance imaging (MRI)
    Mikawa, M
    Miwa, N
    Bräutigam, M
    Akaike, T
    Maruyama, A
    CHEMISTRY LETTERS, 1998, (07) : 693 - 694
  • [43] Nuclear Magnetic Resonance: the Contrast Imaging Problem
    Bonnard, Bernard
    Chyba, Monique
    Glaser, Steffen J.
    Marriott, John
    Sugny, Dominique
    2011 50TH IEEE CONFERENCE ON DECISION AND CONTROL AND EUROPEAN CONTROL CONFERENCE (CDC-ECC), 2011, : 5559 - 5564
  • [44] CONTRAST OPTIMIZATION IN MAGNETIC-RESONANCE-IMAGING
    SPRAWLS, P
    STEINBRUEGGE, C
    MEDICAL PHYSICS, 1986, 13 (04) : 584 - 584
  • [45] Innovation in contrast agents for magnetic resonance imaging
    Marzola, Pasquina
    Boschi, Federico
    Sbarbati, Andrea
    CURRENT MEDICAL IMAGING REVIEWS, 2006, 2 (03) : 291 - 298
  • [46] Contrast stretching for brain magnetic resonance imaging
    Lee, Hyun-Gyu
    Park, Joonseok
    Lee, Sang-Chul
    2018 INTERNATIONAL CONFERENCE ON ELECTRONICS, INFORMATION, AND COMMUNICATION (ICEIC), 2018, : 138 - 140
  • [47] Nanoshell magnetic resonance imaging contrast agents
    Su, Chia-Hao
    Sheu, Hwo-Shuenn
    Lin, Chia-Yun
    Huang, Chih-Chia
    Lo, Yi-Wei
    Pu, Ying-Chih
    Weng, Jun-Cheng
    Shieh, Dar-Bin
    Chen, Jyh-Horng
    Yeh, Chen-Sheng
    MICROPROCESSES AND NANOTECHNOLOGY 2007, DIGEST OF PAPERS, 2007, : 272 - +
  • [48] Cardiovascular magnetic resonance phase contrast imaging
    Krishna S. Nayak
    Jon-Fredrik Nielsen
    Matt A. Bernstein
    Michael Markl
    Peter D. Gatehouse
    Rene M. Botnar
    David Saloner
    Christine Lorenz
    Han Wen
    Bob S. Hu
    Frederick H. Epstein
    John N. Oshinski
    Subha V. Raman
    Journal of Cardiovascular Magnetic Resonance, 17
  • [49] Contrast Medium in the Magnetic Resonance Imaging (Gadolinium)
    Bollkaemper, Andreas
    RADIOLOGE, 2018, 58 (04): : 384 - 385
  • [50] Potential contrast agents for magnetic resonance imaging
    I. Coroiu
    Al. Darabont
    D. E. Demco
    Applied Magnetic Resonance, 1998, 15 : 531 - 538