Influence of Loading and Use of Occlusal Splint in Implant-Supported Fixed Prostheses

被引:14
|
作者
Teixeira, Fabiola Marchezini [1 ]
de Assis Claro, Cristiane Aparecida [1 ]
Claro Neves, Ana Christina [1 ]
Rode, Sigmar de Mello [2 ]
da Silva-Concilio, Lais Regiane [1 ]
机构
[1] Univ Taubate, Dept Prosthodont, Grad Program Dent, Sao Paulo, Brazil
[2] Univ State Sao Paulo, Dept Dent Mat, Sao Jose dos Campos Dent Coll, Sao Paulo, Brazil
关键词
Dental implant; fixed partial dentures; bruxism; photoelastic stress analysis; FINITE-ELEMENT-ANALYSIS; STRESS-DISTRIBUTION; OSSEOINTEGRATED IMPLANTS; SLEEP BRUXISM; BONE LOSS; 15-YEAR;
D O I
10.1097/SCS.0b013e31825aad82
中图分类号
R61 [外科手术学];
学科分类号
摘要
The aim of the study was to assess the tensions generated in the long axis of the implants and the interimplants in the cervical, middle, and apical regions when subjected to different loads with or without interposition of the flat occlusal plane splint. A photoelastic model was made with 2 external hexagon implants located in the space corresponding to the second premolar and molar inferiors. A screw-retained metal superstructure was installed on the implants with a torque of 20 N.cm, and the set (photoelastic model with superstructure) were positioned in the circular polariscope in the dark-field configuration to observe the distribution of isochromatic fringes around the implants and interimplant areas. Photographic records were obtained before the application of the occlusal load with the following loading conditions: 300, 600, and 900 N, with and without interposition of the occlusal plane splint. The decrease in stress with the application of the flat occlusal plane splint became more evident after the application of the 600-N load. Generally, the major stress magnitude occurred in the cervical region for interimplant areas and in the apical region around implants. Use of occlusal splint in the loading of 300, 600, and 900 N reduced tension 33.22%, 66.66%, and 73.33%, respectively, in the samples. It can be concluded that the interposition of the occlusal plane splint caused a reduction in tension resulting from the simulation of occlusal overload.
引用
收藏
页码:E477 / E480
页数:4
相关论文
共 50 条
  • [31] Comparison of fixed implant-supported prostheses, removable implant-supported prostheses, and complete dentures: patient satisfaction and oral health-related quality of life
    Oh, Sung-Hee
    Kim, Younhee
    Park, Joo-Yeon
    Jung, Yea Ji
    Kim, Seong-Kyun
    Park, Sun-Young
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (02) : E31 - E37
  • [32] The influence of functional forces on the biomechanics of implant-supported prostheses -: a review
    Sahin, S
    Çehreli, MC
    Yalçin, E
    JOURNAL OF DENTISTRY, 2002, 30 (7-8) : 271 - 282
  • [33] The use of implant-supported prostheses in rehabilitation of tumor-patients.
    Schädler, M
    Müller, F
    Wahlmann, U
    Wegener, J
    Kuffner, HD
    Wagner, W
    Scheller, H
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A326 - A326
  • [34] Outcome assessment of implant-supported prostheses
    Feine, JS
    Dufresne, E
    Boudrias, P
    Lund, JP
    JOURNAL OF PROSTHETIC DENTISTRY, 1998, 79 (05): : 575 - 579
  • [35] Stress Analysis of Implant-Supported Removable Partial Denture with Anterior Fixed Prostheses and Conventional Implant-Supported Overdentures in the Edentulous Mandible
    Ozel, Gulsum Sayin
    Ozyilmaz, Ozgun Yusuf
    Inan, Ozgur
    JOURNAL OF ADVANCED ORAL RESEARCH, 2022, 13 (01) : 43 - 52
  • [36] A comprehensive study on the mechanical effects of implant-supported prostheses under multi-directional loading and different occlusal contact points
    Tak, Sangmyeong
    Jeong, Yuwon
    Kim, Jong-Eun
    Kim, Jee-Hwan
    Lee, Hyeonjong
    BMC ORAL HEALTH, 2023, 23 (01)
  • [37] A comprehensive study on the mechanical effects of implant-supported prostheses under multi-directional loading and different occlusal contact points
    Sangmyeong Tak
    Yuwon Jeong
    Jong-Eun Kim
    Jee-Hwan Kim
    Hyeonjong Lee
    BMC Oral Health, 23
  • [38] Influence of the casting technique and dynamic loading on screw detorque and misfit of single unit implant-supported prostheses
    Brilhante Bhering, Claudia Lopes
    Ferreira Koyama Takahashi, Jessica Mie
    Luthi, Leonardo Flores
    Pessanha Henriques, Guilherme Elias .
    Xediek Consani, Rafael Leonardo
    Mesquita, Marcelo Ferraz
    ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (3-4) : 404 - 409
  • [39] Fracture behavior of all-ceramic, implant-supported, and tooth-implant-supported fixed dental prostheses
    Alkharrat, Abdul Rahman
    Schmitter, Marc
    Rues, Stefan
    Rammelsberg, Peter
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (04) : 1663 - 1673
  • [40] Bone loss of immediately loaded implants with implant-supported and tooth-implant-supported fixed maxillary prostheses
    Heinemann, Friedhelm
    Mundt, Torsten
    Schwahn, Christian
    Hasan, Istabrak
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 (01): : 33 - 38