Signal intensity of motor and sensory cortices on T2-weighted and FLAIR images: intraindividual comparison of 1.5T and 3T MRI

被引:22
|
作者
Kamada, Koji [1 ]
Kakeda, Shingo [1 ]
Ohnari, Norihiro [1 ]
Moriya, Junji [1 ]
Sato, Toru [1 ]
Korogi, Yukunori [1 ]
机构
[1] Univ Occupat & Environm Hlth, Dept Radiol, Yahatanishi Ku, Kitakyushu, Fukuoka 8078555, Japan
关键词
3T MR; Brain anatomy; Brain cortex; Brain iron;
D O I
10.1007/s00330-008-1069-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We compared the signal intensity of motor and sensory cortices on T2-weighted and FLAIR images obtained at 3T and 1.5T. MR images of 101 consecutive neurologically normal patients who underwent both 1.5T and 3T MRI were retrospectively evaluated. The signal intensities of motor and sensory cortices were analyzed both visually and quantitatively in comparison with superior frontal cortex. On T2-weighted images, decreased signal intensity of the motor cortex was seen in 6 (32%) of 19 patients aged 61-70 years and 14 (48%) of 29 at 71 years and older at 3T, compared with only 1 (5%) and 2 (7%) at 1.5T, respectively. On FLAIR images, the decreased signal intensity in the motor cortex was also more frequently seen at 3T than at 1.5T. The mean CNRs of motor and sensory cortices were significantly higher at 3T than at 1.5T on both T2-weighted and FLAIR images. The decreased signal intensity in the motor cortex was frequently seen at 3T compared with 1.5T. Knowledge of the finding at 3T can help the recognition of abnormalities of the motor cortex caused by various pathologic conditions.
引用
收藏
页码:2949 / 2955
页数:7
相关论文
共 50 条
  • [41] Bilateral pulvinar signal intensity decrease on T2-weighted images in patients with aspartylglucosaminuria
    Autti, T.
    Lonnqvist, T.
    Joensuu, R.
    ACTA RADIOLOGICA, 2008, 49 (06) : 687 - 692
  • [42] Vacuum disc: frequency of high signal intensity on T2-weighted MR images
    M. E. Schweitzer
    K. I. El-Noueam
    Skeletal Radiology, 1998, 27 : 83 - 86
  • [43] Electromagnetic Exposure of Personnel Involved in Cardiac MRI Examinations in 1.5T, 3T and 7T Scanners
    Sklinda, Katarzyna
    Karpowicz, Jolanta
    Stepniewski, Andrzej
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (01)
  • [44] Vacuum disc: frequency of high signal intensity on T2-weighted MR images
    Schweitzer, ME
    El-Noueam, KI
    SKELETAL RADIOLOGY, 1998, 27 (02) : 83 - 86
  • [45] Wireless video transmission into the MRI magnet room: implementation and evaluation at 1.5T, 3T and 7T
    Hensen, Bennet
    Kaegebein, Urte
    Gutberlet, Marcel
    Ringe, Kristina, I
    Van Dai Vo-Chieu
    Stucht, Daniel
    Speck, Oliver
    Vick, Ralf
    Wacker, Frank
    Pannicke, Enrico
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2019, 64 (04): : 373 - 382
  • [46] Occult Amyloid-β-Related Angiitis: Neuroimaging Findings at 1.5T, 3T, and 7T MRI
    Ozutemiz, Can
    Hussein, Haitham M.
    Ikramuddin, Salman
    Clark, H. Brent
    Charidimou, Andreas
    Streib, Christopher
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (08) : 1013 - 1018
  • [47] The relationship between myocardial and hepatic T2 and T2*at 1.5T and 3T MRI in normal and iron-overloaded patients
    Kritsaneepaiboon, Supika
    Ina, Natee
    Chotsampancharoen, Thirachit
    Roymanee, Supaporn
    Cheewatanakornkul, Sirichai
    ACTA RADIOLOGICA, 2018, 59 (03) : 355 - 362
  • [48] Hepatic steatosis modeling and MRI signal simulations for comparison of single- and dual-R2* models and estimation of fat fraction at 1.5T and 3T
    Shrestha U.
    Esparza J.P.
    Satapathy S.K.
    Vanatta J.M.
    Abramson Z.R.
    Tipirneni-Sajja A.
    Comput. Biol. Med., 2024,
  • [49] Hyperpolarized 129Xe gas transfer MRI: the transition from 1.5T to 3T
    Wang, Ziyi
    He, Mu
    Bier, Elianna
    Rankine, Leith
    Schrank, Geoffry
    Rajagopal, Sudarshan
    Huang, Yuh-Chin
    Kelsey, Christopher
    Womack, Samantha
    Mammarappallil, Joseph
    Driehuys, Bastiaan
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (06) : 2374 - 2383
  • [50] A robust method to estimate the intracranial volume across MRI field strengths (1.5T and 3T)
    Keihaninejad, Shiva
    Heckemann, Rolf A.
    Fagiolo, Gianlorenzo
    Symms, Mark R.
    Hajnal, Joseph V.
    Hammers, Alexander
    NEUROIMAGE, 2010, 50 (04) : 1427 - 1437