Active Power Filter with Common DC Link for Compensation of Harmonic Distortion in Power Grids

被引:0
|
作者
Habibullin, Maksim [1 ]
Pikalov, Vladimir [1 ]
Mescheryakov, Viktor [1 ]
Valtchev, Stanimir [2 ]
机构
[1] Lipetsk State Tech Univ, Lipetsk 398600, Russia
[2] Nova Univ Lisbon, UNINOVA, Dept Elect Engn, Caparica, Portugal
关键词
Nonlinear load; Quality of electric energy; Total harmonic distortion; Relay current control; DC-link; Active power filter with Common DC Link;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The growing number of consumers representing non-linear loads has led to an increase in the level of harmonics and poor power quality. It is not news to apply active power filtering (APF), but the drawback is the lower efficiency and complexity. The described here active power filter control system is simpler and more efficient. It is based on a relay current regulator and its converter uses the existing DC bus of the rectifier. The theoretical basis of the APF is described. A model of the proposed APF (with its suggested control system and the common DC link) is simulated in Matlab. The result of this simulation demonstrates that the level of the Total Harmonic Distortion (THD) of the input current is less than 3 %. The input current matches the phase of the input (mains) voltage: i.e. the consumption of reactive power from the grid is minimized. The simulation is confirmed by experimental study of the APF with Common DC Link. The corresponding results are provided.
引用
收藏
页码:1345 / 1349
页数:5
相关论文
共 50 条
  • [21] Implementation of active power filter with asymmetrical inverter legs for harmonic and reactive power compensation
    Lin, BR
    Yang, TY
    ELECTRIC POWER SYSTEMS RESEARCH, 2005, 73 (02) : 227 - 237
  • [22] Single-phase active power filter for reactive power and harmonic compensation.
    Cortés, L
    Horta, S
    Claudio, A
    Cárdenas, VM
    CIEP'98: VI IEEE INTERNATIONAL POWER ELECTRONICS CONGRESS, TECHNICAL PROCEEDINGS, 1998, : 184 - 187
  • [23] An Active Power Filter with Energy Storage and Double DC Conversion for Power Surge Compensation
    Baszynski, Marcin
    Sowa, Kacper
    Pirog, Stanislaw
    ELECTRONICS, 2020, 9 (09) : 1 - 17
  • [24] A predictive control based selective harmonic compensation for active power filter
    Li, Guohua
    Zhang, Ying
    Wang, Yufeng
    Sun, Qiang
    Dianwang Jishu/Power System Technology, 2014, 38 (10): : 2938 - 2942
  • [25] A high power active filter for harmonic. compensation in an electric locomotive
    Li, RM
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 1059 - 1063
  • [26] An Improved Harmonic Detection based on Lead Compensation for Active Power Filter
    Xu, Jun
    Chen, Min
    Ju, Jianyong
    Xu, Dehong
    2008 IEEE 11TH WORKSHOP ON CONTROL AND MODELING FOR POWER ELECTRONICS, 2008, : 300 - 305
  • [27] Compensation characteristics of active power filter to different types of harmonic sources
    Yao, Weizheng
    Wang, Qun
    Liu, Jinjun
    Wang, Zhaoan
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2000, 15 (06): : 40 - 44
  • [28] Harmonic Current Compensation for LCL Filtered Shunt Active Power Filter
    Woo, Deokyong
    Kim, Sungmin
    2024 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, APEC, 2024, : 2266 - 2271
  • [29] Islanding detection method based on active power filter and harmonic compensation
    Dong L.
    Tian H.
    Xiao F.
    Han J.
    Liao X.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (04): : 133 - 138
  • [30] Series active power filter for current harmonic and load voltage compensation
    Chiang, Huann-Keng
    Lin, Bor-Ren
    Wu, Kuan-Wei
    TENCON 2005 - 2005 IEEE REGION 10 CONFERENCE, VOLS 1-5, 2006, : 2460 - +