Non-invasive quantitative assessment of oxidative metabolism in quadriceps muscles by near infrared spectroscopy

被引:41
|
作者
Ding, H [1 ]
Wang, G [1 ]
Lei, W [1 ]
Wang, R [1 ]
Huang, L [1 ]
Xia, Q [1 ]
Wu, J [1 ]
机构
[1] Tsing Hua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
关键词
recovery; muscle; oxygen saturation; exercise; elite athletes;
D O I
10.1136/bjsm.35.6.441
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Background-Near infrared spectroscopy can be used in non-invasive monitoring of changes in skeletal muscle oxygenation in exercising subjects. Objective-To evaluate whether this method can be used to assess metabolic capacity of muscles. Two distinctive variables abstracted from a curve of changes in muscle oxygenation were assessed. Methods-Exercise on a cycle ergometer was performed by 18 elite male athletes and eight healthy young men. A measuring probe was placed on the skin of the quadriceps muscle to measure reflected light at two wavelengths (760 and 850 nm), so that the relative index of muscle oxygenation could be calculated. Exercise intensity was increased from 50 W in 50 W increments until the subject was exhausted. During exercise, changes in muscle oxygenation and blood lactate concentration were recorded. The following two variables for assessment of muscle oxygenation were then abstracted and analysed by plotting curves of changes in muscle oxygenation: the rate of recovery of muscle oxygen saturation (R-R) and the relative value of the effective decrease in muscle oxygenation (D-eff). Results-Data analysis showed a correlation between muscle oxygenation and blood lactate concentration at the various exercise intensities and verified the feasibility of the experiment. Data for the athletes were compared with those for the controls using the Aspin-Welch test of significance; t = 2.3 and 2.86 for R-R and D-eff respectively. There were significant differences (p = 0.05) between the athletes and the control group with respect to these two variables. Conclusion-R-R and D-eff may be distinctive variables that can be used to characterise muscle oxidative metabolism during human body movement.
引用
收藏
页码:441 / 444
页数:4
相关论文
共 50 条
  • [21] NEAR INFRARED SPECTROSCOPY (NIRS) APPLICATIONS IN MEDICAL: NON-INVASIVE AND INVASIVE LEUKEMIA SCREENING
    Ismail, Ruhaizan
    Rahim, Herlina Abdul
    Abd Rahim, Intan Maisarah
    Ghazali, Rashidah
    JURNAL TEKNOLOGI, 2016, 78 (7-4): : 15 - 25
  • [22] Near-infrared spectroscopy as a potential non-invasive tool in the assessment of disease activity in vitiligo patients
    De Bruyne, Sander
    Speeckaert, Reinhart
    Himpe, Jonas
    Delanghe, Joris R.
    EXPERIMENTAL DERMATOLOGY, 2020, 29 (06) : 570 - 574
  • [23] Near infrared spectroscopy for non-invasive assessment of intracranial haemoglobin oxygenation in an in vitro model of the calf head
    Pringle, J
    Art, T
    Lekeux, P
    RESEARCH IN VETERINARY SCIENCE, 1998, 65 (02) : 103 - 109
  • [24] Near-infrared diffuse correlation spectroscopy: the future of non-invasive assessment of skeletal muscle oxygenation?
    Carr, Jay
    JOURNAL OF PHYSIOLOGY-LONDON, 2019, 597 (15): : 3795 - 3797
  • [25] Non-invasive Longitudinal Assessment of Cerebrovascular Reactivity after TBI using functional Near Infrared Spectroscopy
    Sangobowale, Michael
    Morrison, Justin
    Amyot, Franck
    Ayaz, Hasan
    Reddy, Yerram
    Kulkarni, Nimay
    Silverman, Erika
    Meredith-Duliba, Tawny
    Moyer, Megan
    Sandsmark, Danielle
    Diaz-Arrastia, Ramon
    NEUROLOGY, 2019, 92 (15)
  • [26] Rapid non-invasive assessment of quality parameters in ground soybean using near-infrared spectroscopy
    dos Santos, Larissa Rocha
    Zangirolami, Marcela de Souza
    Silva, Nubia Oliveira
    Valderrama, Patricia
    Marco, Paulo Henrique
    PESQUISA AGROPECUARIA BRASILEIRA, 2018, 53 (01) : 97 - 104
  • [27] Assessment of the hypoxic-ischemic encephalopathy in neonates using non-invasive near-infrared spectroscopy
    Huang, L
    Ding, H
    Hou, XL
    Zhou, CL
    Wang, GZ
    Tian, FH
    PHYSIOLOGICAL MEASUREMENT, 2004, 25 (03) : 749 - 761
  • [28] Non-Invasive Assessment of Blood Glucose Changes with Near Infrared Sensor
    Mamilov, Serhii
    Velyhotskyi, Dmytro
    Yesman, Serhii
    Mysiura, Anatolii
    Bekh, Ihor
    Gisbrecht, Alexander
    2020 IEEE 40TH INTERNATIONAL CONFERENCE ON ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2020, : 536 - 540
  • [29] Non-invasive identification of melanoma with near-infrared and skin impedance spectroscopy
    Boden, Ida
    Nystrom, Josefina
    Lundskog, Bertil
    Zazo, Virginia
    Geladi, Paul
    Lindholm-Sethson, Britta
    Naredi, Peter
    SKIN RESEARCH AND TECHNOLOGY, 2013, 19 (01) : E473 - E478
  • [30] Non-invasive monitoring of brain tissue temperature by near-infrared spectroscopy
    Hollis, VS
    Binzoni, T
    Delpy, DT
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE IV, 2001, 4250 : 470 - 481